Water Spray System
HMV & MV Water Spray System We are one of the most reliable and genuine service providers offering Water Spray System Installation Services. We are backed by dexterous team members having huge industry experience, expertise in this domain; they make sure that the Water Spray Systems are installed properly using latest technology and modern machines. We ensure that the Water Spray System Installation Services are as per the customers’ need and requirements. M.V. Water Spray System : Entire area is flooded with foam, hence very useful for fire fighting in hazardous area, plant, storage tanks, etc. where manual approach is difficult. Very quick in response. The fire losses is kept low as the area under fire get foam blanket and also cooling due to water contain and so chances of spreading fire is negligible. HM.V. Water Spray System : Entire Transformer is flooded with water, which extinguish fire at earliest as well as avoid further destruction. Very quick in response. The fire losses is kept low as the area near fire get cooling due to water and so chances of spreading fire is negligible Application : In control of highly flammable liquids(MVWS), oil filled high voltage transformers, warehouses, storerooms, refineries chemical waste water treatment, plants & other industrial sector.
...morewater line pipe
We are renowned and trusted enterprises in the industry, offering a best quality array of Water Piping Service to our esteemed customers. These products are made from high quality components. Features: Long service life Smooth performance Immaculate finish Simple design Easy to use Enhanced durability
...morespray suppression system
Spray suppression system are most commonly used water-based suppressions system for general fire fighting requirements. These employ foam-based suppressions Conventional Fire Detection & Notifications techniques. In our range,
...moreSafe Condition Sign
These signs should he used to indicate escape routes, emergency exits and the like. Some UK fire safety signs in this category are not required by the Health and Safety (Safety Signs and Signals)Regulations 1996. For example “PUSH BAR TO OPEN” is not required to comply and there is no pictogram with that meaning. Such signs are still needed for compliance with fire risk assessment and in some cases the Health and Safety at Work Act 1974.Safe condition signs consist of a green rectangle or square with the pictogram or text in white positioned centrally.
...moreportable fire extinguishers
We provide all type of fire extinguisher like A B C Type Dry Powder Fire Extinguisher, CO2 Fire Extinguisher, Dry Powder Fire Extinguisher, Mechanical Foam (Afff) Fire Extinguisher, Modular Automatic Fire Extinguisher, Water CO2 Type Fire Extinguisher, Clean Agent Fire Extinguisher and all kind of Fire Fighting Equipments. We provide complete Fire Extinguisher products range and after sales services on all India bases.
...moreLuminescent Signs
Luminescent signs with the Regulatory Reform (Fire Safety) Order 2005, in respect of premises, where necessary, in order to safeguard the safety of relevant persons, emergency routes and exits must be indicated by signs.
...moreFoam Water Spray System
AFFF Foam Fire Protection System Foam water spray systems can be used for a combination of Class A and Class B hazards. They are mostly applicable to the protection of two-dimensional flammable liquid hazards. Method of operation for foam water spray systemsFoam water systems generally work by allowing foam concentrate to mix with water flowing into the piping system. These systems are equipped with a bladder tank containing foam. When a fire is detected a signal is sent to the releasing panel to open the deluge valve allowing water to flow. At the same time, piping to the bladder tank flows and pressurizes the outer shell of the bladder tank which forces foam concentrate to travel into the system piping and then into the Foam Proportioner. The foam solution produced by water and foam concentrate flows into the system piping and is discharged through the open nozzles or sprinklers Foam water spray systems can be used for discharge of water first, followed by discharge of foam for a pre-determined period, and then followed by water until manual shut off.Types of foam water spray systems Self-contained AFFF 500 and 300 Foam water systems are generally divided into the following four (4) categories: Wet pipe systems Dry pipe systems Deluge systems Preaction systems Types of foam concentrateVarious types of foam concentrate exist, in accordance with the application considered. Typical foam concentrate types are the following: Aqueous Film-Forming Foam Concentrate (AFFF). Film-Forming Fluoroprotein Foam Concentrate (FFFP). Alcohol-Resistant Foam Concentrate, used for fighting fires on materials usually destructive to regular AFFF or FFFP foams as well as fires involving hydrocarbons. Fluoroprotein Foam Concentrate. Synthetic Foam Concentrate. In general, different types and/or brands of foam concentrates shall not be mixed together.
...moreFire Suppression System
FM 200 & CO2 Fire Suppression system ZoomOur range of automatic fire suppression systems are most commonly used water-based suppressions system for general fire fighting requirements. These employ foam-based suppressions Conventional Fire Detection & Notifications techniques. In our range, we offer: Automatic water sprinklers are used where quicker responses are required Automatic gas-based system is used to protect expensive industrial equipment CO 2 and FM200 are commonly used fire extinguishing gases.( Being a leader in the industry, we are engaged in offering a qualitative range of CO2 Fire Suppression System to our clients. Finding its application in liquid storage areas, spray booths, turbine-driven generators, electrical areas etc., it is used for controlling fire in case of emergency. The provided system is manufactured using quality tested components with the help of sophisticated techniques. Additionally, the offered CO2 Fire Suppression System can be bought from from us at economical price by our valuable patrons. Key Points: Economical installation costs Reduced venting requirement Sturdiness Available with constant flow of water Application: Pump room, control room, electronics, medical equipments, production equipments, telecommunication rooms, switch rooms, engine compartments, and engine and machinery spaces.
...moreFire Sprinkler System
Our company is one of the foremost Service Provider of Fire Sprinkler System, which is also known as Water Monitoring system for fire fighting. It provides a complete solution against intense fires and highly demanded for its hassle free performance. The offered system is made by using the finest quality components and sophisticated techniques, under the directions of our team of diligent professionals. Moreover, we are offering the Fire Sprinkler System in various specifications at nominal rates. Water sprinklers provide an automatic spray dedicated to the area of fire outbreak Sprinkler heads have temperature sensitive elements that respond immediately to heat A rapid response which reduces and isolates fire damage, sprinklers use less water to control a fire than the firefighting service, therefore preventing further damage from excess water. Installation Criteria Pipe materials - Copper tube (BS EN 1057) - Post-chlorinated polyvinylchloride (CPVC) System -mains supplied, wet. Pipe sizes - 25 mm minimum Sprinkler head spacing - area covered by one head, maximum 12 m2 . Maximum distance between heads 4 m. Maximum distance from wall to ceiling mounted head 2 m. Operating pressure - Minimum 0.5 bar (50 kPa). Other Details :Helps to determine the water demand accurately, by using the latest licensed hydraulic calculation software’s.
...morefire safety signs
To afford compliance with the Regulatory Reform (Fire Safety) Order 2005, in respect of premises, where necessary, in order to safeguard the safety of relevant persons, emergency routes and exits must be indicated by signs.The Health and Safety (Safety Signs and Signals) Regulations 1996 covers the provision of fire safety signs that are required in the workplace.
...moreFire Hydrant System
Being one of the oldest but yet the most effective and common fire fighting solutions , as well designed and laid out Hydrant system forms the backbone of the entire fire fighting system.We are highly acknowledged as the best Service Provider of Hydrant System Fire. It is highly demanded in various buildings or premises, widely used for fire fighting solutions and helps in controlling fire during an emergency. This system is designed to suppress the fire and provide a readily available source of water to any point. Under the supervision of our team of well-trained professionals, the offered system is installed by using the modern tools & techniques and quality-tested components. Apart from this, we are offering the Hydrant System Fire in different specifications at affordable prices.The fire hydrant systems are access points that allow fire authorities to connect hoses and quickly disperse large amounts of water to extinguish flames.The system mainly consists of by a number of components & accessories like Fire pumps ( Jockey Pump, Electric Driven Pump, & Stand-by Diesel driven pump) Fire pumps are usually housed in a pump room very close to the fire tanks. The key thing is that the pumps should be located at a level just below the bottom of the fire tank, so that all the water in the tanks can flow into the pumps by gravity.Like all important systems, there must be backup pumps in case the main pump fails. There is a main pump that is electric, a backup pump that is electric, and a second backup pump that is diesel-powered, in case the electricity fails, which is common. Each of these pumps is capable of pumping the required amount of water individually - they are identical in capacity.There is also a fourth type of pump called a jockey pump. This is a small pump attached to the system that continually switches on to maintain the correct pressure in the distribution systems, which is normally 7 Kg/cm2 or 100 psi. If there is a small leakage somewhere in the system, the jockey pump will switch on to compensate for it. Each jockey pump will also have a backup., The capacity of the pumps is decided by considering a number of factors, some of which are:the area covered by hydrants / standpipes and sprinklers The number of hydrants and sprinklers The assumed area of operation of the sprinklers The type and layout of the building Dry Rising Main (Dry Riser). A vertical pipe installed in a building for fire fighting purposes, fitted with inlet connections at fire engine access level and landing valves on various floors, which is normally dry but is capable of being charged with water usually by pumping from fire engine pumps. Dry rising mains are basically dry water pipes. The empty mains need to be charged with water through the breeching inlets by fire appliance. The dry rising mains should not exceed 60m to avoid excessive pumping pressure.Wet Rising Main (Wet Riser). A vertical pipe installed in a building for fire fighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves on various floors. Wet rising mains are constantly charged with water that provide the required flow rate and pressure for fire fighting and equipped with water storage capacity for a given duration of 60 minutes. The breeching inlets, which are usually provided at ground level, are meant for replenishing the water tank.The distribution system consists of steel or galvanised steel pipes that are painted red. These can be welded together to make secure joints, or attached with special clamps. When running underground, they are wrapped with a special coating that prevents corrosion and protects the pipe. External (Stand Post Type Or Underground Type – Sluice Valve, Water Monitor)The amount of water in the fire storage tanks is determined by the hazard level of the project under consideration. Most building codes have at least three levels, namely, Light Hazard (such as schools, residential buildings and offices), Ordinary Hazard (such as most factories and warehouses), and High Hazard (places which store or use flammable materials like foam factories, aircraft hangars, paint factories, fireworks factories). The relevant building code lists which type of structure falls in each category. The quantity of water to be stored is usually given in hours of pumping capacity. In system with a capacity of one hour, the tanks are made large enough to supply the fire with water for a period of one hour when the fire pumps are switched on. For example, building codes may require light hazard systems to have one hour’s capacity and high hazard 3 or 4 hours capacity. The water is usually stored in concrete underground tanks. It is essential to ensure that this store of water always remains full, so it must have no outlets apart from the ones that lead to the fire pumps. These tanks are separate from the tanks used to supply water to occupants, which are usually called domestic water tanks. Designers will also try and ensure that the water in the fire tanks does not get stagnant and develop algae, which could clog the pipes and pumps, rendering the system useless in a fire.Guidelines and approval for hydrant system are available from various national and international organizations like NBC, NFPA,TAC,IS,FM & Local Authorities.
...moreFIRE FIGHTING EQUIPMENT SIGNS
These signs are used to mark the location of fire-fighting equipment and fire alarm activation points. However, where possible, fire equipment should be positioned where it is clearly visible. The Health and Safety (Safety Signs and Signals)Regulations 1996 require red to be used as the identifying colour for fire-fighting equipment. If the equipment itself is red this will satisfy the requirement. Where it is not red then highlighting the position of fire-fighting equipment, by colouring the background behind the equipment red, may be enough to comply.Fire equipment signs consist of a red rectangle or square with the pictogram in white positioned centrally on the sign.
...moreFire Detection System
Being a customer-oriented firm, we are offering the service of Fire Detection and Alarm System. It is used to detect fire, smoke, carbon monoxide or other emergencies occurrence in a particular area and help to warn the people through audio & video appliances.. In includes the following types of Fire Alarm System : Linear Heat sensing system (LHS) High sensitive smoke detection (HSSD) Conventional Fire alarm system Addressable Fire alarm system Conventional Type Of Fire Detection System: Conventional fire alarm panels were the normal place in every building prior to the 21 century. In a zoned system, fire alarm devices in a common area or floor of a facility are connected to the same alarm initiating circuit. A zoned panel is installed with the exact amount of zones need at the time of install and not for future installs. This arrangement allows alarm annunciation to be reported by areas of the building to identify which device is in-alarm. Conventional panels are often used in small facilities where a few zones can provide sufficient alarm annunciation. Addressable Type Of Fire Detection System:Addressable fire alarm systems use digital encoding and multiplex technology to more accurately identify alarm locations and device conditions. Each fire alarm device in a system is programmed with a unique address. The fire alarm control panel is capable of communicating with a single address or a group of addresses depending on the functions required. The communication is often multiplexed over a common cable, sometimes referred to as the signaling line circuit (SLC). This arrangement significantly reduces the amount of cabling necessary to install the system. The communication channel allows two-way communication, thus enabling the fire alarm control panel to control as well as monitor fire alarm devices. A significant component of addressable fire alarm system is the software programming necessary to make the system function correctly. The programming allows for flexible applications where you want to have specific control over the inputs and outputs. As per the NFPA-72, IBC, IS, Local, NBC standards, we design Fire Detection system We have been associated with all the leading OEM. It is used to detect fire occurrence or any intrusion detection in a particular area. In case of fire, smoke, carbon monoxide or other emergencies, this device is used to detect and warn the people through audio & video appliances
...moreFire Alarm System
Fire Alarm System In addition to, or as an alternative to, automatic smoke or fire sensing switches, manual break-glass alarm switches can be wall mounted at about 1.5 m above floor level in lobbies, corridors and other common access locations. No person should have to travel more than 30 m to use an alarm System control unit is an alarm panel which monitors the state of all parts (zones) of the installation. It identifies the point of origin of an alarm, displays this on the panel and communicates this to remote control locations. It is an integral part of any fire protection system. It is said that the first five minutes of fire are most important than the next five hours. Fire can be extinguished when it is in an incipient stage. Moreover people can be warned of fire hazards and evacuation of the buildings becomes easy. The heat & smoke detectors detect fire and actuate the alarm system. The system helps evacuation of the premises and to bring fire fighting facilities into action as quickly as possible. The Fire alarm systems are provided in the residential buildings with heights above 15 m and industrial and commercial buildings with height above 24 m. If the height of building is above 35 m. It is necessary to have provision of heat & Smoke Detectors.
...moreexit signs
Every doorway or other exit providing access to a means of escape, other than exits in ordinary use, should be provided with an exit sign. Installation of signs conforming to British Standard 5499 will satisfy this requirement.Illumination of signsExit signs should be legible at all material times. In premises where emergency lighting has been considered necessary for means of escape purposes, such signs should be illuminated by the emergency lighting supply in the event of a failure of the normal lighting. Any of the following methods are considered suitable : lamps external to the sign but providing adequate illumination of it lamps contained within the sign (internally illuminated signs), or luminous signs requiring no external power source.
...moreDry Chemical Powder Fire Extinguishing System
Dry Chemical is a powder composed of very small particles usually of sodium bicarbonate, potassium bicarbonate, urea-based potassium bicarbonate, or monoammonium phosphate with added particulate material supplemented by special treatment to provide resistance to packing, resistance to moisture absorption (caking) and the proper flow capabilities[fire Extinguishing Mechanisms] : Interruption of the chain reaction sequence. Heat absorption effects Multipurpose Dry Chemical is usually monoammonium phosphate-based and is effective on fires in ordinary combustibles, such as wood or paper, as well as on fires in flammable liquids, etc Characteristics Best applicable to fire extinguishing systems for protection of dangerous and associate articles which involve serious hazard and the danger of quick spread of fire. Easy to clean arter application of Dry chemicals Economical as they are less contaminative. Excellent insulation permits application of Dry chemicals to high-tension electric installation such as a transformer. Handling of Control Valve is simple and plain ensuring easy cleaning of piping after use Total Flooding System A total flooding system means a supply of dry chemical permanently connected to fixed piping,wiht fixed nozzles arranged to discharge dry chemical into an enclosed space or enclosure about the hazard. This type of system shall be used only where there is a permanent enclosure about the hazard that is adequate to enable the required concentration to be built up. The leakage of dry chemical from the protected space shall be minimized since the effectiveness of the flooding system depends upon obtaining an extinguishing concentration of dry chemical. In total flooding system, the rate of application shall be such that the design concentration in all parts of the enclosure shall be obtained within 30 seconds. Local Application System Local application system shall be used for the extinguishment of fires in flammable or combustible liquids, gases, and shallow solids such as paint deposits, where the hazard is not enclosed or where the enclosure does not conform to the requirements for total flooding. Application of dry chemical shall be from nozzles mounted on the tank side or overhead. Area MethodApplicable to superficial fire, and the amount of extinguishing agent depends upon the hazardous area.Volume MethodApplicable to cubical fire, and the amount of extinguishing agent depends upon the volume of the object in danger.The hazard shall include all areas that are or may become coated by combustible or flammable liquids or shallow solid coatings, such as areas subject to spillage, leakage, dripping, splashing, or condensation, and all associated materials or equipment such as freshly coated stock, drainboards, hoods, ducts, etc. that might extend fire outside or lead fire into the protected area.
...moreAir Line Pipes
Backed by a team of skilled professionals, we are able to offer Air Piping Services of superior quality to our valuable clients. We make available these products in different specifications, as per requirements of our esteemed clients. Our offered piping is available in different specifications, as per various requirements of our clients. We offer the product at promised time periods to our clients.Features of Compressed Air Piping Systems: Lower installation cost Push to connect concept No corrosion/low friction coefficient Powder coated Modular design/minimise Pr. drop for optimum flow Re-usable materials Easy to install 16 mm - 100 mm diameter pipe sizes Installs faster than other piping No threading, welding and brazing pipe Simple to use, mounting and connecting hardware Can connect to existing systems with other pipes Easy to add on to or disassemble for your changing needs Corrosion free hence do not generally any contamination & develops with pinholes
...moreFire Buckets
Fire Hose Box
Mild Steel Tank Installation Services
Mild Steel & Stainless Steel Tank Installation Services
Industrial Ducting Work
Industrial exhaust ducts are pipe systems that connect hoods to industrial chimneys through other components of exhaust systems like fans, collectors, etc. Ducts are low-pressure pneumatic conveyors to convey dust, particles, shavings, fumes, or chemical hazardous components from air in the vicinity to a shop floor or any other specific locations like tanks, sanding machines, or laboratory hoods. Ducts can be fabricated from a variety of materials including carbon steel, stainless steel, PVC, and fiberglass. [1] They can be fabricated through rolling (preferable for ducts of 12" or more in diameter) or extruded (for ducts up to 18").The Function Of Industrial Ducting To Remove Hazardous Gases, Fumes, Fog, Dust, Heat, & Unwanted Gases To Maintain Fresh & Clean Environment. To Increase Human Efficiency & Remove Human Fatigue. It Is Now Necessary To Make Green Surrounding to maintain our Earth Green!
...moreFire Safety Training
Training of personnel to handle a fire situation and effectively operate both hand fire appliances and fixed equipment, installed within the premises, say of a factory or high rise buildings, is normally overlooked. This is incredible in view of the fact that the owner has spent several hundred lakhs to install the best of equipment to protect life and property. In the event of fire emergency, the people around must respond very quickly and put to gainful use of equipment's. In Addition to this a disaster management plan should be worked out by the owner and made known to all the persons working within the premises. Fire safety Measures Safety Measures : Apart from the training needs it is necessary to follow certain precautions and alertness while fire is on. Where ever the height of your building, ensure you follow some basic precautions which will be explained you while fire safety training at premises.Fire and Safety Training List: Training Program on awareness of fire prevention & First Aid Training Program on fire fighting & rescue Operation with mock drill Training program on fire mock drill Training Program on industrial safety & prevention of accident & First Aid Training program on industrial workers health, Environment & Safety Training Program in industrial accident & Safety Mgt.
...morefire safety audit
Safety Audit is management tool comprising of a systematic ,periodic and objective evaluation of how well the safety organization, management and equipment are performing, with the aim of helps to safeguard a company’s assets by facilitating management control of safety, health and environmental practices and assessing compliance with established standards. Conduct an inspection of your plant of fixed fire fighting installation and fire equipment and lay down provision conduct safety audit and submit the report on safety audit as per ISI and TAC norms Scope of Audit: Full Workplace (Multi-occupied Premises) Fire Safety Audit Checklist Workplace Regulations Firefighting & Detection Emergency Routes & Exits Maintenance Fire Risk Assessment (FRA) Objectives of AuditThe objectives of Fire Safety Audit can be focused on the following: Identify all significant fire hazards. Identify the people who are at risk from each hazards. Evaluate the existing control measures. Determine the additional control measures required. Examine the availability of suitable emergency plan detailing responsibility and action of key personnel. Review the availability of suitable fire alarm and detection system. Review the availability of suitable fire fighting facilities, such as hydrants, sprinklers, extinguishers, etc. Evaluate passive fire protection systems provided. Evaluate the general awareness of occupants and security personnel on matters relating to fire safety and rescue operations. Evaluate the training and instructions on fire safety imparted to the employees and occupants. Testing of all fire safety equipment and systems.
...moreFire Retardant Door Installation
Fire Doors help protect assets by stopping fire, smoke and heat from entering an area. Fire doors allow certain areas to be compartmentalized so that fire, smoke and heat cannot penetrate through; thus minimizing damage to property and lives. Fire Doors provide such protection when installed as the access doors to such compartments. Fire doors are ideal for high rise buildings, commercial and industrial units. Fire Doors are ideal for high rise buildings, commercial and residential complexes, malls, multiplexes, IT buildings where the finishes have to match the aesthetics of the interior work.
...moreFire Protection System Design & Engineering
S.R Enterprises has been designing fire protection systems for over 7 years, and in recent years. , we work under a philosophy of cohesive design from concept to execution, which provides our clients with feasible, practical, goal-oriented fire protection systems design. Throughout the phases of a traditional design, we integrate the necessary elements in order to present a prescriptive fire protection system that is cost-effective to install and maintain.Our in-house engineering department is the most experienced in the industry and uniquely qualified to provide detailed designs for all types of systems including fire protection design, fire alarm system design, fire suppression system design, and sprinkler system design. Fire protection engineers’ work with architects and other engineers, state and local building officials and local fire departments to build and maintain fire safe communities. They make recommendations for cost effective fire protection solutions to ensure that the structure and the property and occupants contained within are adequately protected.For challenging designs which may involve life safety, property protection, mission continuity, heritage preservation, and environmental protection, our engineers develop a performance-based design, which focuses on specific protection criteriaS.R Enterprises offers the following design services: Engineering Design AutoCAD Pre-design site visits Complete permitting services We design systems that meet your objectives Flexibility built into each design Thorough knowledge of equipment A seamless installation team Design systems that control fires, alert people to danger, and provide means for escape; Evaluate buildings to pinpoint the risks of fires and the means to prevent them; Conduct fire safety research on consumer products and construction materials; Investigate fires to discover how fire spreads, why protective measures failed, and how those measures could have been designed more effectively. Identify relevant fire safety codes, standards and regulations, comprehend the fire safety performance objectives and criteria associated with these documents, and apply these fire safety objectives and criteria to a broad range of applications. Analyze the flammability characteristics of different materials, interpret the results of standard and non-standard fire test methods and evaluate the fire hazards associated with different materials in a range of anticipated settings. Analyze the dynamics of fires in and around buildings and other structures through the application of fundamental principles and the use of state-of-the-art computer-based fire simulation models. Understand how people interact with fire conditions in buildings and calculate evacuation times through the application of fundamental principles of people movement and the use of state-of-the-art computer-based evacuation models. Perform comprehensive fire and life safety evaluations of buildings and other structures through application of the knowledge, skills and tools acquired in this program and effectively communicate the results and findings of such evaluations.
...moreAnnual Maintenance Contract
Offer consistent flawless operation, we undertake AMC for Fire Protection Systems for each product. We maintain an AMC Fire Fighting Systems with our clients in which we upgrade fire safety equipments and systems installed in clients premises and remove the flaws if any.This helps in extending the life of the equipment installed at our customers end.Through this maintenance service, we can maintain the smooth & error free functionality of the systems. We provide optimum Amc ( Annual Maintenance Contract) Services of Fire Fighting Systems, Fire Hydrant Systems, Automatic Fire Sprinkler Systems, Fire Alarm, Fire Detection, Fire Suppression Systems with full satisfaction of Clients.Highlights Reduced risks of failure of equipment when the need arises - saving your investments and your business. Extended life from your equipment due to preventive maintenance visits. Compliance with local fire office and insurance company requirements. Affordable price We Also provide Fire Protection Consultant Services.
...moreFire Fighting System Consultant & Licensing
Fire NOC consultation service/ Consultancy & Licensing of fire fighting system Under the Maharashtra Fire Prevention & Life Safety Measures Act-2006, adhering to National Building Code of India, 2005, We provide or consult following services too. We get Licensing with Respective Fire Dept : Industrial Fire Noc Provisional Fire No Objection Certificate Part Final No Objection Certificate Final No Objection Certificate Renewal of Final No Objection Certificate: Building Fire Noc Fire Provisional No Objection Certificate Revised Fire Provisional No Objection Certificate Final Fire No Objection Certificate We also issue : Form A & Form B A certificate regarding the compliance of the fire prevention and life safety measures in a building or a part thereof as required by or under the provisions of the Act, to be issued by a Licensed Agency, shall be in “Form – A”. A certificate which is to be issued by a Licensed Agency twice a year in the months of January and July regarding the maintenance of fire prevention and life safety measures in a building or premises being in good repair and efficient condition as specified in sub-section (1) of section 3 of the Act.