Solar Mini Inverter
We are offering solar mini inverter. solar mini inverter suitable for the load ;- ac led lamps or cfl, mini inverter is with buit in mobile charging faility as well as ac (mains) charger model 1 solar mini inverter with built in 12 v 7ah smf battery suitable for max 3 cfl ( 11 watt) for back up to 2 hrs, solar as well as ac charger & mobile charging facility specifications: mini inverter with built in 12 v 7 ah smf battery: 20 watt solar panel: approx 3 metr with connector for solar panel in above model # 1: if 3 lamps of 4 watt each connected back up will be approx 4-5 hours model 2 solar mini inverter without battery suitable to run max 3 cfl ( 11 watt) for longer back up, solar as well as 2 amp ac charger & mobile charging facility specifications: mini inverter without battery: 30 watt solar panel: approx 3 metr with connector for solar panel note: in solar mini inverter model no 2 you can connect battery max up 32 ah & solar panel max 50 watt load back up depends on battery ah
Brand Name : Powerline
...moreSolar Inverter (Power Conditioning Unit)
We are offering Solar Inverter (Power Conditioning Unit). When the single battery voltage is between 10.5 V to 13 V, the inverter unit selects the Mains supply line (if present) as well as solar power & the inverter will compare itself the voltage generated by both (By Mains power & Solar power). If voltage generated through solar power is more battery will start charging maximum through solar power only & vice versa During this cycle the load will operate on Mains (if present) Battery will be charged up to Max 14.2 v in above case. When the battery voltage reaches 14.2V, the unit switches over to the Inverter mode, charging continues from the solar supply and the load gets shifted from Mains to the Battery(the INV ON indicator lights up) , even if the Mains is present . The unit is then supposed to have entered into SOLAR ZONE. In this zone, the Solar energy stored in the battery is utilized, which saves the electricity. Suppose during this cycle load connected through inverter is 300 watt & solar power generated through solar panels is 200 watt, then 100 watts only will be used through battery At battery voltage 14.2 V, the charging(either from Solar or from Mains) stops, then starts again when it falls down to 13.8V(when Solar present), again stops at 14.2 V. This is the trickle charging operation. if Mains supply cuts off during the solar zone, the unit maintains its “solar-zone” mode. Therefore, when the Mains supply resumes, the unit continues to operate in Inverter mode and the load is supplied by the battery. When the battery voltage reaches 11.5 V during the solar zone, the unit switches back to the Mains Supply, the charging continues from solar or mains supply and the load gets connected to Mains Supply. We reserve the 11.5 to 10.5 voltage of battery for emergency use (If Mains & Solar power both are not available) When the battery voltage reaches up to 10.5V, the unit enters in a shut down mode.
Brand Name : Powerline
...moreIntelligent Power Selector (Solar Charger)
We are offering intelligent power selector (solar charger). The intelligent power selector (ips) converts any conventional inverter into a solar inverter.(pcu) with ips product series we are targeting large customer base of existing installed home ups & inverters to convert them to solar inverter. Our ips solution will assist in reducing electricity bills & ensure a dependable back up system, contribute proudly to clean environment. The product can be customized for many other applications beyond the inverter. It is also a self-sufficient solar dc power system by adding ips to your normal inverter, you will get all the features of our smart solar inverter in your converted inverter system which can be used in home and street lighting applications. It provides the facility to charge the battery bank either through solar or grid(priority will be to solar )the ips continuously monitors the state of battery voltage, solar power output and the loads. When the batteries are charged above a preset level, the grid power supply to the ips automatically cuts off from the system, in the presence of solar. The ips is designed to give priority to solar power first and use grid power only when the solar power battery charge is insufficient to meet the load requirement. It switches to grid charging automatically due to sustained usage of power, when the battery voltage falls below a preset level, the ips transfers the load automatically to the grid power and also charges the batteries through the inverter in-built solar grid charger. The salient features include: maximization of solar energy harvest higher power conversion efficiency universal inverter ups compatibility affordable roof top solar system solutions lower electricity bills dependable back up system integrated high efficiency solar charge controllers these can be used in wide-ranging applications in solar systems such as industrial power plants, rooftop solar banking power, water pumps or simply home & office ups systems.
Brand Name : Powerline
...moreLed Solar Lantern
We are offering 1 watt led solar lantern. Led 1 watt high power led battery 3.6v, li-ion battery ac adapter solar panel 3 watt abs plastic body back up time up to 6 hours
Brand Name : Powerline
...moreSolar Mppt Charger
We are offering solar mppt charge controller with built in energy meter & with gsm facility. You can monitor all the technical data of mppt on your mobile
...moreSolar Charge Controllers
Solar Inverter
Solar Lanterns
solar mini inverters
Solar Street Lights
solar water pumping solutions
Be first to Rate
Rate ThisOpening Hours