Air Flow Meters
18,000 - 58,000 Per Piece
1 pieces (MOQ)
Precision Air flow measurement up to Pressure ranges 0-8barsg and temp Range Ambient to 80 degrees celcius.a ¹
Dwyer Air Velocity Transmitter
Get Price Quote
Dwyer Air Velocity Transmitter Series 641RM Air Velocity Transmitter with Remote Probe For Remotely Mounting Electronic Enclosure The SERIES 641RM features the same highly accurate heated mass flow sensor as the Series 641, with a remote probe construction. The units 6´ cable which connects the sensing probe with the electronic enclosure allows the enclosure to be mounted where it can be more easily accessed. Product Applications Exhaust stack flow monitoring Air control in drying processes HVAC air velocity measurements Fan supply and exhaust tracking Clean room ventilation monitoring ModelDescription 641RM-12Air velocity transmitter, without LED display. 641RM-12-LEDAir velocity transmitter, with LED display. Dwyer Air Velocity Transmitter Series 641RM Air Velocity Transmitter with Remote Probe For Remotely Mounting Electronic Enclosure The SERIES 641RM features the same highly accurate heated mass flow sensor as the Series 641, with a remote probe construction. The units 6´ cable which connects the sensing probe with the electronic enclosure allows the enclosure to be mounted where it can be more easily accessed. Product Applications Exhaust stack flow monitoring Air control in drying processes HVAC air velocity measurements Fan supply and exhaust tracking Clean room ventilation monitoring ModelDescription 641RM-12Air velocity transmitter, without LED display. 641RM-12-LEDAir velocity transmitter, with LED display. Specifications Service:Clean air and compatible, non-combustible gases. Accuracy:3% FS Process gas: 32 to 122°F (0 to 50°C); 4% FS Process gas: -40 to 32°F & 122 to 212°F (-40 to 0°C & 50 to 100°C). Response Time:Flow: 1.5 s to 95% of final value (output filter set to min.). Temperature Limits:Process: -40 to 212°F (-40 to 100°C). Ambient: 32 to 140°F (0 to 60°C). Pressure Limit:100 psi (6.89 bar) maximum. Humidity Limit:Non-Condensing. Power Requirements:12 to 35 VDC, 10 to 16 VAC. 1.5 A rating required on supply due to initial power surge drawn by transmitter. Output Signal:4 to 20 mA, isolated 24 V source, 3 or 4-wire connection. Output Filter:Selectable 0.5-15 s. Loop Resistance:600 Ω max. Current Consumption:300 mA max. Electrical Connections:Screw terminal. Mounting Orientation:Unit not position sensitive. Probe must be aligned with airflow. Weight:13.2 oz (374.26 g). Cable Length:6' (1.82 m). Probe Length:12" (30.48 cm) standard. Probe Diameter:5/16" (0.79 cm). OPTIONAL DISPLAY VERSION: Display:4-1/2 digit 1/2" red LED. Resolution:1 FPM, 0.01 MPS (10 FPM @ 10,000 and 15,000 FPM ranges). Weight:13.9 oz (394.16 g).
Best Deals from Air Meters
Compressed Air In-Line Flow Meter
80,000 Per Piece
1 Piece (MOQ)
VPFlowscope In-line - Compressed air & industrial gases flow meter. It measures mass,flow,temparature and pressure simuntanously.Features: Thermabridge Technology For compressed air and oxygen RS-485 Modbus, 4 to 20mA output Bi-directional Application: Point of use in compressed air systems Output of oxygen generators Consumption measurement leakage measurement Cost allocation and measuring distribution network
Air Velocity Meter
Get Price Quote
velocity meter
Get Price Quote
Microprocessor Based, Direct Velocity meter which gives the Velocity (in m/ sec) of water of canal/ river with the help of the water current meter. It has large intelligent LCD display 16-character x 1 line. Low Power consumption, Battery Operated. The constant of the individual current meter sensor can be entered/ changed by the keys on the penal of the meter. It has in built memory to store the 50 numbers of velocity data.
Air Entrainment Meter
Get Price Quote
We make sure; our products are produced using top grade materials sourced from reliable vendors only. We are here to guide our clients with the secure payment procedures. With us, the customers get convenience to pay through both online and offline payment methodsSpecification : Capacity - 0.005 m3 (5 Litres) Suitable for aggregate size upto 38 mm Dimension - 370X370X550 mm
Compressed Air Flow Meter
Get Price Quote
1 piece (MOQ)
Compressed Air Flow Meter
80,000 - 120,000 Per Piece
01 Piece (MOQ)
Air Quality Meter
10,000 - 12,000 Per piece
1 piece (MOQ)
Air Entrainment Meter
18,500 - 18,500 Per piece
1 Piece (MOQ)
Casella Type Air Velocity Meter
Get Price Quote
1 Piece (MOQ)
The traditional method for measuring the flow of air blown up through a grain heap. Suited to under-floor systems and blowing fans, the meter is used to confirm that there is adequate flow of air emitting from the surface of the grain. Ventilated grain ensures that the moisture content of the stored grain is kept within a safe limit by the steady flow of air through the grain. The INDUS Crop Airflow Meter for grain is an essential instrument for the successful storage of grain in bulk where under-floor blowing systems are in use.Principle of operationA lightweight float, made from a thin aluminium disc, moves up and down a tapered transparent tube. A wire running through the centre holds the float in place. The float has been designed to spin, removing possible errors by reducing friction. Air passing up the tube supports the float at a height where its weight is balanced by the pressure drop of the air. A scale on front side gives the flow rate in ft/min. On the opposite side of the tube is a white strip to aid reading the flow rate.
Air Entrainment Meter
Get Price Quote
Air Entrainment Meter
11,000 - 12,500 Per Piece
1 Piece(s) (MOQ)
Owing to our rich networking sources, we are able to procure an excellent range of Air Entrainment Meter for buyers in the domestic markets. Our Air Entrainment Meters are precisely-engineered using superior grade components as a raw materials and modern tools and technologies. These devices conform to the set industrial norms and standards and provide a hassle-free performance for a long period of time. We are a reliable Supplier of Air Entrainment Meter from Delhi, India. Buy them from us at market-leading prices.
Air Entrainment Meter
16,000 Per Piece
1 Piece(s) (MOQ)
Wind Velocity Transmitter
6,000 Per piece
Three conial beaded edged cups 50 mm. In diameter, attached by arms to a central boss drive a vertical spindle at a rotary speed proportional to the wind velocity.Aluminum, Brass and Stainless Steel are used throughout this instrument to ensure freedom from corrosion and long working life. A conical shield protects the spindle and bearing from the rain.An Infra Red Transducer connected to the vertical shaft gives pulses proportional to the number of rotations of the vertical shaft.This signal is carried through interconnecting cable ( standard length 20 mtrs.) to the Transmitter unit.4 - 20 mA OR 0 - 5 Volts Dc output proportional to the wind velocity is provided which can be fed to any Data Logger or PLC.
Model 641B Air Velocity Transmitter
Get Price Quote
Compressed Air Flow Meter
Get Price Quote
1 Piece (MOQ)
Air Quality Meter
Get Price Quote
Air Flow Meter
Get Price Quote
1 Piece(s) (MOQ)
within the working range of the meter the rotor spins proportional to the actual velocity of gaseous material flowing. a pick-up coil produces an electrical signal as each blade crosses through its low magnetic or rf field. this signal is amplified and conditioned by a transmitter or fed directly into a ratetotalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. the k-factor is stenciled on the meter body in pulses per actual cubic feet (pacf). because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60â°f, 14.69 psia). if the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from pacf to pscf and a simple totalizer (measurement systems india make ) may be used. when flow temperature and pressure are not constant, a flow computer. specifications linearity 1 â±1.0%0.5% repeatability 1 â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). materials of construction body: 316 l stainless steel. flanges: 316 stainless steel rotor: 431 stainless steel. rotor shaftbearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. temperature range:meter with bearing structure of: standard: tungsten carbide: -40â°f to 300â°f (-40â°c to 149â°c). for other temperatures consult factory.
AQM-06 Ambient Air Pollution Meter
Get Price Quote
1 Piece (MOQ)