altitude test chamber
25,000 - 150,000 Per Piece
Camber Board
Get Price Quote
Best Deals from Testing Equipment
Box Compression Tester
Get Price Quote
Our entire range is value for money, as it is quality guaranteed, sold after a string of quality control tests, and is relied on by many. We make sure that the products that we deliver will remain completely damage free as we make use of the quality packaging material and have skilled personnel for the packing of the products. Features : Advanced technology Safe & reliable Long lasting & affordable
velocity meter
Get Price Quote
Microprocessor Based, Direct Velocity meter which gives the Velocity (in m/ sec) of water of canal/ river with the help of the water current meter. It has large intelligent LCD display 16-character x 1 line. Low Power consumption, Battery Operated. The constant of the individual current meter sensor can be entered/ changed by the keys on the penal of the meter. It has in built memory to store the 50 numbers of velocity data.
Horizontal Slip Table
Get Price Quote
`TARANG' Combo Base Horizontal Slip Table eliminates the necessity for supporting test specimens by complicated exures and permits simplified transnational motion for testing the components in both horizontal axes X & Y, without disturbing the orientation of tests objects.
Slump Test Apparatus
Get Price Quote
It is used for the determination of the consistency of freshly mixed concrete, where the maximum size of the aggregate does not exceed 38mm. The Apparatus consists of one slump cone with handles and foot pieces. The slump cone has internal dimensions 20cm. dia at base 10cm. top dia. and 30cm height. Foot pieces can be fixed to the clamps on the base plate. The base plate has lifting handle for easy transportation. One steel rod 16mm dia x 600mm long is supplied along with .
DIGITAL GSM TESTER WITH SAMPLE CUTTER
14,500 - 14,500 Per Piece
1 Piece(s) (MOQ)
Hydraulic Bursting Strength Tester
40,000 - 85,000 Per Unit
1 Unit (MOQ)
Digital Ph Meter
5,000 Per Piece
Cobb Sizing Tester
18,500 - 24,500 Per Pcs
1 Piece (MOQ)
COBB SIZING TESTER is designed to determine the water absorbency of paper and board. Water absorbency of paper ( the cobb value) is define as the amount of water absorbed in a given time by one side of a unit area of paper or board placed horizontally under a head of one centimeter of water. Apparatus conforms to International Standard TAPPI T 441-45 and ASTM D 2045-647. SPECIFICATIONS Convenient Sample Clamping Test Cylinder Made of Brass About 5 Cm High, With An Internal Area 100 Cm2 Level Indication on Inside of Cylinder for 100 Ml. Stainless Steel Coach Roll Width 210 Mm, Weight 10+ 05 Kg.
SASA SLUMP TEST APPARATUS
500 - 1,800 Per Piece
5 Piece(s) (MOQ)
Digital Gsm Tester
Get Price Quote
Humidity Test Chamber
Get Price Quote
The Humidity Test Chamber that we offer has made us one of the foremost manufacturers, exporters and suppliers based in Roorkey Uttarakhand. These chambers have a temperature range from -65oC to +125oC and a test space capacity of 50 litres to 8000 litres. The chambers that we offer come with a PID type controller or dual loop microprocessor programmer and recorder.
Phase Angle Meter
Get Price Quote
Phase Angle Meter is a compact direct reading instrument suitable for reading phase angle between voltage-voltage, voltage-current and current-current. In voltage range of 60 of 440 and current range of 1 to 5 Amps. Available in digital and analog read-out it operates on 230V/50Hz
Plate Load Testing Apparatus
Get Price Quote
We offer Plat Load Testing Apparatus, which is extremely acknowledged for its low maintenance, durability and dependability. Dimensional accuracy, sturdy construction and easy operation are some of the salient attributes that make our Plat Load Testing Apparatus highly popular among buyers. We manufacture Plat Load Testing Apparatus using premium raw material that ensures its durability. We are one of the prominent Manufacturers, Exporters and Suppliers of Plat Load Testing Apparatus from Uttarakhand, India.
Digital Ring crush tester microprocessor
Get Price Quote
1 Piece(s) (MOQ)
This tester is used for testing the ring crush strength of the paperboard. With the proper accessories Test Application. Cardboard & Paper Testing · Packaging
Soil Testing Instruments
Get Price Quote
Soil Testing Instruments, Research Equipment, Scientific Instruments
Conductivity Meter
Get Price Quote
We are one of the reliable Suppliers of Conductivity Meter, based in Roorkee, Uttarakhand. Based on advanced technology, Conductivity Meter offers accurate and precise measurement of electrical conductivity in water and other fluids. Conductivity Meter is available in different specifications to cater diverse demands of the clients. Main Features : The portable conductivity meter provides fast, accurate readings, with digital readability and the convenience of a remote probe separately. Multi-measuring ranges : 199.9 uS, 1.999 mS, 19.99 mS. Data hold functions for stored the desired value on display. Large LCD display for low power consumption & clear read-out even in bright ambient light condition. Used the durable, long-lasting components, including a strong, lightweight ABS-plastic housing case
Slump Test Apparatus
Get Price Quote
Specification:-It is used for the determination of the consistency of freshly mixed concrete, where the maximum size of the aggregate does not exceed 38mm.The slump cone has internal dia of 20cm at base and 10cm dia at top and 30cm height.
Air Permeability Apparatus
Get Price Quote
Blaine's air permeability apparatus is used for determining the fineness of cement in terms of specific surface expressed as total surface area in square cm/gm of cement. This is a variable flow type air permeameter.
Digital Time Interval Meter
Get Price Quote
We bring forth Digital Time Interval Meter for offering high efficiency in measuring the time of operation of various protective layers. Our Digital Time Inverter Meter is effective in measuring the opening and closing time of circuit breakers. High resolution and accuracy is guaranteed with our Digital Time Interval Meter. Different operating modes can be selected with our Digital Time Interval Meter, and this feature makes it suitable for use in different field operations. Integrated circuit construction ensures accuracy and reliability even at the smallest time interval measurement. Attributes PortableHoused in leather carrying caseDirect display of time avoids any calculationsProtected against over loads/ short circuitsProvided with reverse polarity indicator in the case of start/ top by step positive voltages Specifications Display : 5 digit LED 12.5 mm high red color Ranges : 99.999, 999.99 and 9999.9 second Measurement Accuracy : 1 milli sec. ± 1 count on lowest range
Horizontal Slip Table
900,000 Per Units
Slump Test Apparatus
1,100 Per Piece
Marshall Test Apparatus
Get Price Quote
We are prominently engaged in providing Marshall Test Apparatus to the customers. This Marshall Test Apparatus method covers the measurement of the resistance to plastic flow of cylindrical specimens of Bituminous paying mixtures loaded on the lateral surface by means of the Marshall Apparatus. This Marshall Test Apparatus method is for used with hot mixtures containing asphalt or far and aggregate up to 25mm maximum size. Apparatus : Specimen Mould Assembly : Mould cylinders 4" (100mm) in diameter by 3 (76mm) in height, base plates, and extension collars shall confirm to the code. Three mould cylinders are recommendedSpecimen Extractor : A specimen extractor to remove the compacted specimen from the specimen moulds recommended. A suitable bar is required to transfer load from the extension collar through a circular steel plate (100mm dia x 12mm thick) supporting a steel rod of 25mm)Compaction Hammer : The compaction hammer shall have a flat, circular tamping face and a 103 B (4.5 kgs) sliding weight with a free fall of 18 inch, two compaction hammers are recommendedCompaction Pedestal : The compaction pedestal shall consists of a 8" x 8" wooden post capped with a 12" x 12" x 1" steel plate. The wooden post shall be oak, yellow pine or other wood having a dry weight of 42 to 48 LBS per cuft. The wooden post shall be secured by four angle iron brackets to a solid concrete slab. The steel cap shall be installed properly so that the post is plumb/straight and cap is levelSpecimen Holder : The specimen holder shall consists of a semi circular base and a circular ring to hold the specimen mould in place during compaction of the specimen, the top section shall be flanged to fit over the collar of the specimen mould and shall be provided in the base for mounting on the compaction pedestal. The specimen mould holder shall be mounted on the pedestal steel cap so that the center of the mould is over the postBreaking Head : The breaking head assembly shall consist of upper and lower cylindrical segment or test heads having an inside radius or curvature of 2" accurately machines. The lower segment shall be mounted on a base having two perpendicular guide rods or posts extending upward. Guide sleeves in the upper segment shall be in such a position as to direct the two segments together without appreciable binding or loss of motion on the guide rodsLoading Frame : The loading frame consists of a power operated screw jack mounted in a steel testing frame and shall produce a uniform vertical movement of 2" per minute the upward and downward movements are automatically controlled by Micro Switches. The testing (load) frame is also provided with a hand wheel (crank) for initialing adjustment or for applying loads in case of power failuresProving Ring Assembly : Own Proving Ring of 3000 kg capacity and sensitivity of 10 - 15 between and 2000 kg shall be equipped with micrometer dial. The micrometer shall be graduated in mms (0.002mm) Proving Ring attachments are required for fastening the Proving Ring to the testing frame and transmitting the load to the breaking head, suitable threads are provided in either side of the loading bosses of the Proving Ring for required fixing Miscellaneous Equipments : Oven or Hot Plate : Oven or Hot Bath should be provided for heating aggregate bituminous material specimen moulds, compaction base etc, and other equipments required or mixing and moulding temperatures. It should recommended that the required temperature with 5F controlled so as to maintain the required temperature within 51 (2.8C) suitable shields, baffle plates or sand baths shall be used on the surfaces of the hot plates so minimize localized over-heating or exposure to cool air in winterMixing Apparatus : Mechanical mixing is recommended. Any type of mechanical mixer may be used provided it can be maintained at the required mixing temperature and will produce a well coated, homogeneous mixture of the required amount in the allow-able time. A metal pan or bowl of sufficient capacity and hand mixing may also be used. Generally, specimen is prepared from the mixer of the hot plant or hot mix laid at siteWater Bath : The Water Bath shall be at least 15cm deep and shall be thermostatically controlled so as to maintain the bath at 140-188F (60oC) the tank shall have a perforated bottom or be equipped with a shelf for supporting specimen 5cm above the bottom of the bathContainers for heating bituminous material, either grill type tins, breakers pouring posts, or saucepans may be usedMixing tool-either steel trowel (Garden type) or spatula, for spreading and hand mixingThermometers of determining temperature of aggregates, bitumen and bituminous mixture. Armored glass thermometers or dial type with Metal stem are recommended. A range of 9.9 to 400/500 F (2 to 24oC) with sensitivity of 5F (2.8C) requiredThermometers for Water Bath with a range of 6F to 158F (20 to 70C) sensitive to 0.4F i.e. 0.2oCBalance 5 kg capacity, sensitive to 0.1gm for weighing molded specimensBalance 5 kg capacity, sensitive to 0.1gm for batching mixturesRubber gloves for removing specimens from water bathMarketing pencils for identifying specimensScoop flat bottom for batching aggregatesSpoon (large) for placing mixtures in specimen moulds Test Specimen : Number If Specimen : Prepare at least three specimens for each combination of aggregates and bitumen contentsPreparation Of Aggregates : Dry aggregates to constant weight at 221 to 231 F (105 to 110 C) and prepare the aggregates by dry sieving into the desired size fractions. The following size fractions are recommended 25mm- 20mm, 20mm to 12.5mm, 12.5mm to 4.75mm and passing 2.36mmDetermination Of Mixing : At compacting temperatures. The temperatures to which the asphalt must be heated to produce viscosity's of 85 to 10 sec saybolt favol and 140-15 sec saybolt farol shall be established as the mixing temperature and compaction temperature, respectively the corresponding viscosity's Farol shall be Englar specific viscosities of 25-3 for mixing and 40-5 for compactingPreparation Of Mixtures : Weight into separate pans for each test specimen, the amount to each size fraction required to produce a batch that will result in compact specimen 2.5"-3" in height (about 1200 G) place the pans on the hot plate or in the oven and that to a temperature of approximately 50 (27.8C) above the mixing bowl and with the heated aggregate and dry thoroughly, from a created in the dry blended aggregate and weight the required amount of a bituminous material into the mixture. At this point the temperature of the aggregate and bituminous material shall be within the limits of the mixing temperature established in paragraph below mix the aggregate and bituminous material rapidly until completely coatedCompaction Of Specimen : Thoroughly clean the specimen moiled assembly and the fact of the hot plate to temperature between 200 and 300 F (93.3 and 148.9C) place a piece of filter paper or paper toweling cut to size in the bottom of the mould before the mixtures is introduced. Place the entire batch in the mould space the mixture vigorously with a heated spatula or trowel to a slightly rounded shape. Temperature of the mixture immediately prior to a compaction shall be within the limits of the compacting temperature established a underPlace the collar and mould assembly on the compaction pedestal in the mould hold and unless otherwise specified, supply 50 blows with a compaction hammer with a free fall of 18 inch. Hold the axis of the compaction hammer perpendicular to the base of the mould assembly during compaction. Remove the base plate and collar and reverse the assembly of the mould. Apply the same number of compaction blows to the face of the reversed specimen. After compaction place the sample extractor plate on the end of the specimen. Place assembly with the extension collar down in the testing machine. Apply pressure by the load transfer bar and force the specimen into the extension collar. Lift the collar from the end of the specimen. Carefully transfer the specimen to smooth flat surface and allow it to stand overnight at room temperature. Weight measure and test the specimen. Table fans may be used. Mixtures that lack sufficient cohesion to result in the required cylindrical shape on removal from the mould immediately after compaction may be cooled, until rapidly cohesion has developed to result in the proper cylinder shape Procdure : Bring the specimens to the desired temperature by immersing them in Water Bath and place the lower segment of the Breaking Head and place the complete assembly in position on the testing machine. Place the dial gauge in position over the support and adjust the gauge at zero while holding in firmly against the upper segmentApply load to the specimen by means of the constant rate of movement of the load jack or testing machine head at 2 in per minute head of 2 inch indicated by the dial. Record the maximum reached load decreased as indicated by the dial. Record the maximum load sautéed on the testing machine or converted from the indicated flow. Recovery of test specimen from the Water Bath to the maximum load determination shall not exceed 30 secondsKeep the test sample in the Water Bath for 30 to 40 minutes, keep the samples in temperature at 140-188F for asphalt specimens and 100 to 118 F (37.8C) for tar specimen as in alternative the specimens may be brought to desired temperature by placing in an oven for minimum of 2 hours. Maintain the oven temperature at 140-188 F (60-70C) for asphalt specimen 100-108F (37.81C) for tar specimen. Thoroughly clean the guide rods and the inside surfaces for the test heads, proper to making the test and laborite the guide rods so that the upper test head slides freely over them. Remove the specimen from the water (for repeat test) and place in the breaking need assembly. Three samples (specimens) to be tested for each varying type mixtures Report (Result) : The report shall include the following information for each specimen tested : Weights of the test specimen. Average of three (3) to be takenMaximum load in kgs corrected when requiredFlow value in hundredth of a millimeterMixing temperatureCompacting temperature and testing temperature
Slump Test Apparatus
Get Price Quote
Digital Gauss Meter
Get Price Quote
Digital Gauss Meter, Standard Capacitors Box (Type -1100 B)
digital multi meter
Get Price Quote
We offer digital multi meter.
Paper Testing Instruments
Get Price Quote
Paper Testing Instruments, paper instruments
environmental testing equipment
Get Price Quote
environmental testing equipment, environmental chamber machine
transformer turn ratio meter
Get Price Quote
transformer turn ratio meter, Digital Voltmeter, Power Analyzer