Harmonic Reactors
50,000 - 400,000 Per Set
1 Set(s) (MOQ)
Harmonic Filter Reactor
Get Price Quote
Filter reactors are our core competency at Quality Power. We have supplied hundreds of reactor upto 145kV system voltage and covering the entire frequency spectrum. Recently we have supplied 2nd Harmonic and 3rd Harmonic filters for Ms Gunung Garuda Steels Ltd, Indonesia.Also we posses a Majority share in the Filter Reactors in South Asian Region and is a well established brand in this part of the world. Alternatively we have exported filers to around 11 countries across the world. We also have executed Harmonic study, Analysis and Execution of the whole Filter bank at Ms Bhushan Steel & Power Ltd at Jharsiguda, Orissa.
Best Deals from Harmonic Filters
detuned reactor
Get Price Quote
APPLICATIONS : Power Factor Panels, Furnace Panels, UPS, Fluroscent Lamps Om make reactors are designed to meet specific design criteria such as Q factor, inductance tolerances etc. series line reactors shall be designed for harmonic filtering service and for slowing the rate of rapid current charges. The reactors shall be UL component - recognized and shall be built to comply to UL 508 construction shall be of copper wire - wound on magnetic steel cores. Series line reactors shall be sized appropriately for the total connected load. Design maximum temperature rise for reactors shall be 115°c on bobbin wound and 155°c on form wound devices at rated circuit. Non-linear equipment generate harmonic as multiples of a fundamental frequency such as AC/DC motor speed controllers, are furnaces compact fluorescent lamps, uninterruptible power sources. As a result of this fact besides the fundamental frequency, 3rd, 5th, 7th, 9th, 13th, harmonic are generated. Specification of Harmonic filter Reactor (Detuned Reactor) Operating Voltage: 3 x 415/440V Supply Frequency: 50/60Hz Filtering Detuning Factor: 5.69%, 7%, 14% corresponding to tuning frequencies of 210Hz, 189Hz, and 134 Hz for the base of 50Hz. Tolerance of Inductance: ± 5% High Linearity: 1.8In (180% ) Over Load Capability: 150 % for 10 minute of Rated current & 200 % 10 Second of Rated current High Voltage Test: 4 KVA Temperature rise: 110° < maximum on full Load Maximum Audible Level at Two (2) Meters : Line / Load Application 76 dBa Standard: IS-5553-/EN-61558-2-20/IEC-60076-6 'CE' approved. PRODUCT RANGE : 5KVAr to 100 KVAr(Copper/Aluminum)
Harmonic Filters
Get Price Quote
Harmonic Filters, metallized film capacitors, L T APP Capacitors
Harmonic Filters
Get Price Quote
Harmonic Filters, Reactors, Transformers, capacitor banks, line traps