voltage monitoring relays
Gennext make Voltage Monitoring Relay (also known as Line Voltage Monitoring Relay or Mains Voltage Monitoring Relay) is designed to provide protection against under voltage, over voltage, single phasing, reverse phasing and unbalanced voltage of Mains supply. It also provides settable power-on delay and trip delay. It comes in din-rail or door mounted cabinet. FEATURES Microcontroller based technology. 7 Segment Digital display for 1 phase voltage and parameter setting. Protection against Undervoltage, Overvoltage. Easily parameter setting by keys. Settable Trip delay for all protection. UV/OV bypass facility. LED indication for relay on. Separate auxillary supply is not required. Available in four models: Single Phase, Door Mounted Single Phase, Din rail Mounted Three Phase, Door Mounted Three Phase, Din rail Mounted
...moreRelay Modules
Gennext manufactures variety of relay cards that includes Engine Start / Stop Relay Cards (12 / 24 VDC, 70 A), Contactor Changover Relay Cards (12 /24 VDC, 5 A), Start / Stop with Fault Relay Cards (12 / 24 VDC, 70 A / 5 A)and Pull Start and Hold Relay Cards (all 12 /24 VDC, 70 A). FEATURES 70A contact rating. 12vdc and 24vdc ratings available. Start / stop LED indications are provided. Load side surge suppressor are provided. Dinrail mounted profile provided. Available in two models: RM04-4T RM04-4T-BLT
...moreRadiator Water Level Controller
Gennext make Radiator Water Level Controller and Sensor is designed to protect the engine from high temperature caused by low radiator water level. The controller has an inbuilt time delay to reduce the risk of intermittent switching through liquid turbulence. FEATURES Microcontroller based design. Protects the Engine From High Engine Temperature because of Low water Level. No Electrolysis. Operates on Engine battery voltage. LED indication and potential free contact for Low water Level. Automatic Fault reset. Supply voltage 0 to 35Vdc. Sensor withstanding temp 200 deg. Size 72×72×30mm. Cutout size is 68×68mm.
...moreelectrical meters
Gennext manufactures wide range of electrical meters that includes Digital Voltmeter, Digital Ammeter, VIF / VAF Meter, KWH Meter and Multifunction Meter. FEATURES Microcontroller based design. Measures 3 phase Line and phase voltage. Auto scroll display. Also measures Kilovolt range. Settable PT ratio. KEYS To enter the CT ratio adjustment and set the CT ratio. TECHNICAL SPECIFICATIONS Overall dimensions 96×96×75. Cutout dimensions 92×92. PT ratio settable range is 1 to 5000. Four digit one line 7 segment display. Supply voltage 230Vac, 50Hz (±10% Line regulation). Sensing Voltage R, Y, B -500Vmax. System accuracy is ±0.5%.
...moreAts Controller
Gennext make ATS controller is designed to monitor Mains supply under voltage, over voltage, single phasing and reverse phasing and provides auto start signal to AMF controller on Mains disproportion. FEATURES ATS controller is used to transfer the load from mains to DG and From DG to Mains very smoothly. It senses 3 phase Mains and DG supply. It reduces LVM, Timers and hence reduces the panel wiring It gives the protection for mains like UV/OV/SPP/RP and unbalance voltage. Settable power on delay, Trip delay, Load transfer delay and cool down delay. It shows Mains Phase and Line voltage readings LED indication for Mains ON, DG ON, Load ON Mains, Load ON DG Autostart input for DG mounted Amf controller. Site voltage calibration possible. Size: 96×96×85mm Cutout size:92×92
...moreamf controllers
Gennext make AMF controller (Auto start on Mains Failure Controller) starts the engine on mains failure and provides necessary engine safety. It also monitors all electrical parameters and transfers the load from Mains to DG and vice-versa. It also provides the potential-free contacts of all faults required for telecom applications. FEATURES Selection of 1500 rpm and 3000 rpm. Reduces the system cost with providing LCD display for Battery voltage, RPM, HZ, Hours. Integrated control buttons and relays will reduce the wiring cost. Emergency stop shutdown integrates timers for both energise to run and energise to stop fuel types. Pull and Hold coil output function. Selectable Auto, Manual, Test and external control modes. 27 variable parameters setting through front panel push buttons. Built in alarm annunciator for emergency faults. Fully sequenced start, stop cycle with clear LED display. Built in watch dog timer makes the system fail safe. Six keys facilitate mode changing, manual operation, fault acknowledge, fault reset, changing display parameter, as well as setting of different parameters. Twenty one LEDs are provided to indicate the status of mains, genset, load, genset faults, displayed parameter and modes. Size: 96×144×38mm Cutout Size: 92×139mm
...moreBe first to Rate
Rate ThisOpening Hours