series reactors
10,000 - 3,000,000 Per Set
1 Set(s) (MOQ)
series reactor
Get Price Quote
In alternating-current power systems for protection against excessively large currents under short-circuit or transient conditions. Series reactor are connected in series with the line or feeder.Basically reactors are used for fault current reduction, Load balancing in parallel Ckt, limitting inrush current of capacitor bank in APFC panel. General Features Single or three phase, high permeable iron core, air gapped design High quality copper or aluminium windings Linearty according to resonance frequency Thermal Switch for overload protection (optional) Vacuum impregnated varnish to ensure silent and moisture-immune operation Reactors manufactured as per IS 5553IEC -60289 (1988)
Best Deals from Line Load Reactors
detuned reactor
Get Price Quote
APPLICATIONS : Power Factor Panels, Furnace Panels, UPS, Fluroscent Lamps Om make reactors are designed to meet specific design criteria such as Q factor, inductance tolerances etc. series line reactors shall be designed for harmonic filtering service and for slowing the rate of rapid current charges. The reactors shall be UL component - recognized and shall be built to comply to UL 508 construction shall be of copper wire - wound on magnetic steel cores. Series line reactors shall be sized appropriately for the total connected load. Design maximum temperature rise for reactors shall be 115°c on bobbin wound and 155°c on form wound devices at rated circuit. Non-linear equipment generate harmonic as multiples of a fundamental frequency such as AC/DC motor speed controllers, are furnaces compact fluorescent lamps, uninterruptible power sources. As a result of this fact besides the fundamental frequency, 3rd, 5th, 7th, 9th, 13th, harmonic are generated. Specification of Harmonic filter Reactor (Detuned Reactor) Operating Voltage: 3 x 415/440V Supply Frequency: 50/60Hz Filtering Detuning Factor: 5.69%, 7%, 14% corresponding to tuning frequencies of 210Hz, 189Hz, and 134 Hz for the base of 50Hz. Tolerance of Inductance: ± 5% High Linearity: 1.8In (180% ) Over Load Capability: 150 % for 10 minute of Rated current & 200 % 10 Second of Rated current High Voltage Test: 4 KVA Temperature rise: 110° < maximum on full Load Maximum Audible Level at Two (2) Meters : Line / Load Application 76 dBa Standard: IS-5553-/EN-61558-2-20/IEC-60076-6 'CE' approved. PRODUCT RANGE : 5KVAr to 100 KVAr(Copper/Aluminum)
Shunt Reactor
Get Price Quote
The need for large shunt reactors appeared when long power transmission lines for system voltage 220 kV & higher were built. The characteristic parameters of a line are the series inductance (due to the magnetic field around the conductors) & the shunt capacitance (due to the electrostatic field to earth). An equivalent diagram for a line is show in the figure below,Both the inductance & the capacitance are distributed along the length of the line. So are the series resistance and the admittance to earth. When the line is loaded, there is a voltage drop along the line due to the series inductance and the series resistance. When the line is energized but not loaded or only loaded with a small current, there is a voltage rise along the line (the Ferranti-effect)
Three Phase Reactor
2,500 Per Units
series reactors
Get Price Quote
series reactors, metallized film capacitors, L T APP Capacitors