Water Level Controller
We present best quality Water Level Controller which is appreciated for its high performance. We make our Water Level Controller with the use of latest technology to ensure easy handling. These Water Level Controllers are tested under stringent industry norms to prevent any faults in performance or flaws. Features Microcontroller based technologyProtection from overload & dry run (Auto push button setting)Useful for 1 Ph. MotorpumpsSeparate indications for Overload, tank full and tank emptyCorrosion free Float sensorAuto Manual Facility Useful For Ground tankOverhead tanks1 ph. sub. pumps
...moreUnique Thermal Overload Relay Unit
Features : Thermal Overload Protection Useful for 3 ph. all type of motor for 0.5 HP. to 7.5 HP. Relay Range 1.5 A- 2.5 A to 13-21 A
...moreUnique EL MCB
Features : Useful for 3 ph. Supply. Range 16 A. 32 A, 63 A & as per requrrement Short circuit ancl Earth leakage protection. Earlh Leakage from 30 MA to 100 MA Settable.
...moreThree Phase Control Panel (model No. Ip 2007)
We are instrumental in offering high quality Three Phase Control Panel to our clients. This Three Phase Control Panel is made with the use of cutting edge technology and are extremely easy to operate. Our Three Phase Control Panel is manufactured from best components and other high grade raw materials which assure endurance and durability. Features Microcontroller based technologyProtection from voltage unbalance, single phasing, overload (thermal) & dry run. (Auto push button setting)Motor starts automatically after time delay 1/3/5 minUseful for 3 Ph. 1 to 7.5 H.P. Openwell, Submersible, Monoblock pumpsetsSeparate indications for Timer, OK, SPP, Dry run & O/LOperates on low voltage (from 250 V)Single Phasing Protection up to motor terminalAuto Manual Facility3 pole MCB for mains ON/OFF & Short circuit protection
...moreSubmersible Pump Starter
Our clients can avail from us Submersible Pump Starters for domestic use which are highly demanded in the market. Our Submersible Pump Starters are manufactured from cutting edge technology and are made as per the international standards. These Submersible Pump Starters are power saving and are economic as well. Available For 0.5 to 3 H.P. units Attributes Thermal Overload ProtectionSuitable for Submersible PumpsVoltage and Current IndicationAutostart facility with on delay timer (1/2/3 min.)
...moreSubmersible MCB Starter
Features : Suitable for Submersible Pumps. Available for 0.5 to 2 H.P. Pumps. MCB Overload Protection. Separate analog meters fbr voltage & cument..
...moreSubmersible Digital Pump Starter
Features Suitablc for I Ph. Subrnersible Pumps. Availablc for l to 2 H.P. Purnps. Overload Protection (2 Pole BCH Type Contactor) Digital A/V Meter for Current & Voltage Display. ISI mark fire proof Cable rviring. Standard make capacitor ri'ith 6 months wananty. Technical Specifications Operating Voltage : 160 \'to 170 VAC Start Capacitor : 120 L50. 1-\0/200 MFD. Run Capacitor : 36/50 NIFD.
...moreSNR-WLC-FS Water Level Controller
Features : Microcontroller based technology. Useful for ground tank, overhead tank for 3PH.& 1 pH. pumps. Seperate indications for tank full for Upper and Lower tank, Corrosion free Float sensor. Economi cal model compared to WLC-A/B/C. Technical Specifi cations : Operating voltage- 70 &270 VAC. 50 Hz.
...moreSNR-WLC-A Water Level Controller
Features : Microcontroller based technolo_ey. Useful for ground tank, overheaitank for I PH. Monoblock and OpenwellPumps. Protection fiom overload & dry run.(auto push button setting). Seperate indications for Oveload, tanktull and tank empty. Con osion free Float sensol. /Stainless Sensor. Auto Manual Facility. Useful for de-watering pumps. Technical Specifications : Operating vol.170 to 270VAC.50 Hz. Overload setting-130% of fuil load. tirne delay-7 sec.
...moreSNR-OW-MCB Open Well Starter
Features : Suitable for Openwell Subrlersible Pumps. Available for 0.5 to 2 H.P. units. MCB Ovcrload Thermal Protcction. Technical Specifications : Operating Voltage - 1 60 V to 270 VAC Current Range- upto 25 amps. OnlyRun Capacitor- 25136150 MFD.
...moreSNR-OW-MCB A Open Well Starter
Features : Suitable for Openwell Subrncrsible Pumps. Available for 0.5 to 2 H.P. units. MCB Overload Thennal Protection. Current indication by analog meter Technical Specifications : Operating Voltage - 1 60 V to 270 VAC Current Range- upto 25 amps. OnlyRun Capacitor- 25136150 MFD.
...moreSNR IP-DMS Control Panel
Features : Micro Controller Based Technology Motor Autostart Facility with setable on delay time. RYB indication for each phase. Protection from voltage unbalance, single phasing, overload, Drymn & also currcnt sensing SPP, (Push button fbr Setting) LED Display for voltagc & ammeter & also indicator 40 A power relay for ON/OFF switching. Compact size. 0/L. percentage can be setable from 110%to 170%. N/L, % can be set from 90o/o to 50o/o Aftcr Dry run trip restart relay facility available (with variable time set). SPP/O/L. protection enable/disable facility. as per DMA Micro Controller Based Technology Motor Autostart with SPP. Useful fbr 3 Ph. 1 to 5 H.P. Openwell, Submersible, Monoblock pumps. 16A BCH type 3 Pole contactor. Auto/Manual Facility Water level contractor facility also available. Technical Specification : Opelating voltage 220 to 460 VAC.50 Hz. Drr Run trip tirning - 7 sec. Or erload Electromagnetic Relay. Drr Run setting - 70% o of fiill load cutrent. SPP Trip tin.re delay- 4 sec. Voltage Unbalance Set. - 35 volts. Voltage Sensing SPP.
...moreSNR-IP 2007 Control Panel
Features : Microcontroller based technology. Motor stafts automatically after time delay l/3/5 min. Protection from voltage & current unbalance, single phasing.overload & dry run. (auto push button setting). RYB indication for each phase, Operates on lowvoltage (from250V) Usefulfor 3 Ph. 1 to 6 H.P. Openwell, Submersible, Monoblock pumpsets.Separate indications for Timer, OK, SPP. Dry run & 0/L. Auto Manual Facility. Single phasing protection upto motor terminal. 3 pole MCB formains ON/OFF & Shorl c ircuit protection Technical Specification : Opelating voltage 220 to 460 VAC.50 Hz. Drr Run trip tirning - 7 sec. Or erload Electromagnetic Relay. Drr Run setting - 70% o of fiill load cutrent. SPP Trip tin.re delay- 4 sec. Voltage Unbalance Set. - 35 volts. Voltage Sensing SPP.
...moresingle phasing preventer
Features : Protection from Voltage Unbalance, Single Phasing, Reverse Phasing. Operates on low voltage (from 200 V) Useful for 3 Ph. 1 to 50 H.P, Openwell, Submersible, Monoblock Pumpsets. Duel colour LE,D indicator Green for OK & Redfor SPP. Technical Specifications Operating voltage : 220to 460 VAC, 50 Hz. SPP Trip time delay- 4 sec. Voltage Unbalance Set.-35 Vph. to ph. SPP -Voltage Sensing.
...moreSingle Phase Digital AV Meter Box
Features : Useful for 1 Ph. Motor Single Digital meter for Amp. and Volt (30A and 300V ac) Seperate RYB Indicator Nano size, long life with 12 months warranty
...moreRYB Phase Digital AV Meter Box
Features : Useful for 3 Ph. Motor upto 10 HP Analog Ammeter 30A & Voltmeter 500V Separate RYB Phase indicator Push button for Voltage check.
...moreRobot Timer
Features : Microcontroller based technoIogy. High_Quatity LED Disptay. Useful for timer for" streetlight, garden lighting. housing Society signboards etc. Separate 2 programe in 1 unit for 2 different applications. Use can be I ph. as well as 3 ph. supply. Auto/Manual Facility. Indicator for each program ON on LED as well as LED display. Low cost, High qualiiy. Domestic Tirner for any timer purpose. Technical Specifications : Microcontroller based techno1ogy. Operating voltage- 220 to 440YAC, 50Hz. 1C PROGRAM CPT)
...moreMobile Start Unit
We are the major Manufacturer, Exporter and Supplier of a quality range of Mobile Start Unit. Specially made using the best grade raw materials and components, our Mobile Start Unit is the best choice available in the markets. In addition to this, we offer our Mobile Start Unit in varied specifications, as per the requirements. The clients can avail this Mobile Start Unit at industry leading prices in the markets. Features Operates from 200 V to 420 VUseful for 3 to 30 HPSeparate indicator for OK & Mobile ONMicro controlled based technologyMotor can be operated by phone on calling or SMS from any destination automatically (mobile network necessary)Mobile auto can operate a specific number (5 Nos.) which will be feed by customer for his convinience to avoid misuse of Mobile AutoUseful for 1 ph. & 3 ph 1 HP to 20 HP openwell, submersible & monoblock pumpsNo need to attach mobile handset with this unit you can direct insert simcard to this unitAuto / Manual & Mobile ON/OFF facility Technical Specifications Operating voltage : 220 to 460 VAC, 50 HzTrip time delay : 4 secondsStar to Delta Time Delay : 7 seconds
...moreMobile Autoswitch GSM
We are the major Manufacturer, Exporter and Supplier of a quality range of Mobile Autoswitch GSM. This Mobile Autoswitch GSM is manufactured with the use of best quality components and other raw materials which impart strength and durability. Our Mobile Autoswitch GSM is known for superior functionality and is provided at affordable prices. Highlights Motor can be operated by phone from any destination automatically (network necessary)Mobile auto can operate a specific number (5 no's) which will be feed by customers for his convenience to avoid misuse of mobile autoMicrocontroller based technologyAuto Manual and mobile ON/OFF facilityYou can get detail technical information by sending SMS for ST about current of each Phase R Y B and also voltage between R Y & Y B & BR at that timeYou will get Audio feedback and SMS feedback of each operation and protectionWhen motor Stops due to no load or overload you will get the current (A) at which current motor got DRYRUN or overload on LCD displayProtection from voltage unbalance. Single phasing & dry run (automatic push button setting)Mobile auto can operate in different language Marathi/Hindi / English /Gujarati / KanadaUseful for 1 Ph. & 3 Ph. 1 to 20 H.P. Openwell, Submersible, Monoblock pump setsSeparate indications for Timer, OK, SPP & Dry runAudio Feed back of each operation and protectionFor details of voice feedback and other information please refer instruction manual with this unitEnable /Disable facility available for each protection and automation (i.e. if you do not require O/L protection then you can disable this protection)
...moreMobile Autoswitch 9000 AM
We present Mobile Autoswitch 9000 AM which are highly demanded in the market. Our Mobile Autoswitch 9000 AM is made as per the industry norms and are user friendly. Our Mobile Autoswitch 9000 AM is properly tested under stringent industry parameters to make sure that that it is free from defects and faults. Features Motor can be operated by phone from any destination automatically (mobile network necessary)Protection from voltage unbalance. Single phasing & dry run (automatic push button setting)Operates on low voltage (from 200 V)Microcontroller based technologyUseful for 1 Ph. & 3 Ph. 3 to 30 H.P. Openwell, Submersible, Monoblock pumpsetsAudio Feed back of each operation and protectionSeparate indications for Timer, OK, SPP & Dry runAuto Manual and mobile bypass facilityFor ON / OFF code and details of voice feedback please refer instruction manual with this unit
...moreMobile Auto Switch Snr-ma-gsm
The mobile autoswitch snr-ma-gsm is an easy to operate machine. Finding wide usage in agricultural field the mobile autoswitch snr-ma-gsm is based on latest technology. The mobile autoswitch snr-ma-gsm consumes less power and is available at the market leading price. features micro controller based technologymotor can be operated by phone on calling or sms from any destination automatically (mobile network necessary) you will get audio feedback and sms feedback of each operation and protectionmobile auto can operate a specific number ( 5 nos.) which will be feed by customer for his convenience to avoid misuse of mobile autoyou can get detail technical information by sending sms for st about current of each phase r y b and also voltage between r y, yb & br at that timewhen motor stops due to no load or overload you will get the current (a) at which current motor got dryrun or overload on lcd displayuseful for 1 ph. & 3 ph 1 hp to 20 hp openwell, submersible & monoblock pumps. protection from voltage unbalance, reverse phasing, single phasing (current sensing) overload, dry runseperate indicator for timer, ok, spp, o/l & n/l and also display on lcdmobile auto can operate in various languagesmarathihindienglishgujarathikanadaenable / disable facility available for each protection & automation(i.e. If you do not require o/l protection then you can disable this protection)no need to attatc mobile handset with this unit you can direct insert sim card to this unitauto / manual & mobile on/off facilityfor details of voice feedback & other information please refer instruction manual with this unit
...moreMCB Submersible Starter with O/L Protection
Features : Suitable for 1 Ph. Submersible Pumps. Available for lto 2H.P. Purnps. MCB Ovcrload Protection. Separate Ammeter & Voltmeter for Voltage and Cunent.
...moreFully Automatic Sub Control Panel
Features : Micro Controller Based Technology. Suitable for 1 Ph. Submersible Pumps. Available for 0.5 H'P. to 3 H.P. Sub Pumps. LED display for each Protection & facility. Auto set as per motor cument (as Per HP) Voltage & current shows continuously on LED display one by one. 0/L.& D/R% Setable After D/R Restart Setable (1 min. to 180min.) Water level Controller facility available for upper tank. (SNR/EP/2007/DMCI/A- On & Off timc settable (Cyclic) (1 min. to 255 min. ) as per your requirement. SNR/EP/2007/DMCI - Off time settable (1 min. to 255 min.) Auto Start after powcr come back (auto delay timer)
...morefloat sensor
Features : Useful for waterlevel controller as water level sensor. Antirust ABS plastic enclosure. With No, COM., NC contacts. Economical & Maintenance free Longlife with 12 m warranty.