VIF Meter
Getting information at a single place is more convenient. In industrial panels, placing three Voltmeters and Ammeter and a Frequency meter is more space consuming. Instead of using three Voltmeters, Ammeter and a Frequency meter separately, we can use all these seven meters in a single meter. This reduces more space on panel door. SYCON VIF Meter 9990 is made for the same. SYCON VIF Meter 9990 is capable of measuring six voltages, three currents and a frequency in a single unit. VIF Meter continuously senses three input phase voltages with neutral and phase currents and displays. General Features Combined display Voltage, Current and Frequency. Friendly user interface. Easy to install.
Frequency : 50Hz± 5%
...moreSycon-8805 - Protection Relay
We are offering sycon-8805 - protection relay. Now a days in industries people suffering cause of three phase load problemsburns due to single phasing. Sycon provides solution on that in form of single phase preventor.
...moreSycon-8802 - Protection Relay
We are offering sycon-8802 - protection relay. The voltage relay sycon 8802 relay generally measures the phase-to-phase voltage of the system. On operation the relay trips the circuit-breaker or provides an alarm signal, in accordance with the configuration of the relay.when the phase-to-phase voltage exceeds the set start value of the overvoltage stage, the overvoltage stage starts and generates an over voltage fault signal. When, operate time has expired, the overvoltage stage delivers a trip signal. In the same way the undervoltage stage starts and generates a under voltage fault signal, when the value measured goes below the start value, and when the operate time has expired, the undervoltage stage operates by generating a trip signal.when the difference between any two phases is greater than 10% of normal voltage, voltage unbalance stage starts and when the operate time has expired, the voltage unbalance stage operates by generating a trip signal.
...moreprotection relay
We are offering protection relay. Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. Sycon – 772x earth leakage relay continuously detects the leakage current with the help of cbct (core balance current transformer.) the cbct is mounted externally. The overall load current whose leakage current is to be detect, current carrying cables it may be 3 phase supply or 1 phase supply are passed through the cbct. Cbct detects the level of current and trip the device at set current & time.
...moreSycon-770x Earth Leakage Relay
We are offering sycon-770x earth leakage relay. Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. Sycon 770x earth leakage relay continuously detects the leakage current with the help of cbct (core balance current transformer.) the cbct is mounted externally. The current carrying cables (it may be 3 phase supply or 1 phase supply) are passed through the cbct. Cbct detects the level of current and trip the device at set current & time.
...moreSYCON-66 XX SS - Automatic Power Factor Controller
We offer Sycon-66 Xx Ss - Automatic Power Factor Controller. This advance version in 66 series with small volume and light weight, displays all parameters like system power factor voltage, current, system KVA, system KVAr, system KW, shortfall KVAr, THD. It works on smart switching algorithm where a number of capacitors can be turned ON or OFF instantaneously used on the capacitive KVAr requirement. It also displays harmonics from 3rd to 13th. It has capability to auto-identify the capacitor values. All the settings are password protected. It has in-built capacitor protection system in case of harmonic overload and over-voltage. With in-built TEST mode, the panel can be tested without CT curre
...moreAutomatic Power Factor Controller
We are offering automatic power factor controller. Certain elctricals loads such as motors found in heavy machinneries ,can cause the electrical system to be highly inductive. This result in poor power factor . Poor power factor means higher energy losses which ultimately get converted into large electricity chrges. A simple solution to this problem is to balance this inductive load with equivalent capacitive load . Tis is achieved by connecting or disconnecting the capacitors to or from the system. Manual switching of these capacitors is not possible in case of rapidly fluctuating loads . So even in an environment of rapidly fluctuating loads to achieve the required power factor one may need an automatic power factor control device, called automatic power factor controller, to connect and disconnect these capacitors. Sycon 66 xx e3 controller is an automatic power factor controller used to control the power factor of the system . It can sense the powre factor of each individual phase in the three phase system and can switch the capacitors according to the requirement.
...moreSYCON-66 XX - Automatic Power Factor Controller
This version of 66 XX series displays all parameters such as power factor, shortfall KVAR Excess KVAR , voltage, current and THD all at a time. By selection, it displays % harmonic from 3rd to 13th and capacitor values. It has built in facility to cut-off the capacitors in case of harmonic overload. It has password protected settings. It’s built-in TEST mode enables to test the panel without CT current. Auto as well as Manual mode of operation are available in this relay.
...moreSYCON-55 XX - Automatic Power Factor Controller
We offer SYCON-55 XX - Automatic Power Factor Controller. This 55 series version uses microcontroller technology but with necessary and sufficient features. The main feature is two point setting to avoid hunting at site by user convenience which eliminates calculations and setting of CK. The switching sequence is in "First In First Out" i.e. FIFO manner. It is very easy to install and its bright 4-digit 7-segment display makes it readable from dis
...moreSYCON-55 XX-2D - Automatic Power Factor Controller
We are offering sycon-55 xx-2d - automatic power factor controller. This 55 series version is similar to sycon 55 series model of apfc in all respects except the display, the price and the size of the controller. It uses 2-digit 7-segment bright display for power factor indication. Two separate leds are used to give leadlag indication. It is smaller and lighter in weight than the regular sycon 55 series model. This low cost version is very popular for smaller automatic power factor correction systems.
...moreprotection relay
We are offering protection relay. Electric motors are crucial component in virtually every industrial automation application or environment. Therefore optimizing their performance and reliability can play a major role in reducing costs and improving overall plant efficiency. Electric motors fail and about half of them fail because of overheating through overload, phase failure or insulation breakdown. There are wide ranges of motors and motor characteristics in existence, because of numerous duties for which they are used and all of them need protection. Fortunately, the more fundamental problems affecting the choice of protection are independent on the type of motor and the type of load to which it is connected. Motor characteristics must be carefully considered when applying protection. It is emphasized because it applies more to motor than other items of power system plant. Protection of motor exists in any form, a variety of designs & either packaged individually or in different combinations. The fundamental and basic aim should be permit the motor to operate up to, but not to exceed its thermal and mechanical limits for overloads and abnormal operation conditions and to provide maximum sensitivity to faults.
...moreprotection relay
We are offering protection relay. Electric motors are crucial component in virtually every industrial automation application or environment. Therefore optimizing their performance and reliability can play a major role in reducing costs and improving overall plant efficiency. Electric motors fail and about half of them fail because of overheating through overload, phase failure or insulation breakdown. There are wide ranges of motors and motor characteristics in existence, because of numerous duties for which they are used and all of them need protection. Fortunately, the more fundamental problems affecting the choice of protection are independent on the type of motor and the type of load to which it is connected. Motor characteristics must be carefully considered when applying protection. It is emphasized because it applies more to motor than other items of power system plant. Protection of motor exists in any form, a variety of designs either packaged individually or in different combinations. The fundamental and basic aim should be permit the motor to operate up to, but not to exceed its thermal and mechanical limits for overloads and abnormal operation conditions and to provide maximum sensitivity to faults.
...moreSingle Phase Protection Relay
Now a days in industries people suffering cause of three phase load problemsburns due to single phasing. SYCON provides Solution On that in form of Single Phase Preventor. General Features Easy installation User Friendly
Frequency : 50 Hz
...moreseries reactor
In alternating-current power systems for protection against excessively large currents under short-circuit or transient conditions. Series reactor are connected in series with the line or feeder.Basically reactors are used for fault current reduction, Load balancing in parallel Ckt, limitting inrush current of capacitor bank in APFC panel. General Features Single or three phase, high permeable iron core, air gapped design High quality copper or aluminium windings Linearty according to resonance frequency Thermal Switch for overload protection (optional) Vacuum impregnated varnish to ensure silent and moisture-immune operation Reactors manufactured as per IS 5553IEC -60289 (1988)
...morepf meter
Two digit LED display of Power Factor Lag and Lead indication by LED Friendly user interface. Easy to install.
...moreMultifunction Energy Meter
In today’s industries, knowing more about your power system is necessary to get control over it. This requires a system or a Meter which is capable of getting measurement continuously from your power system. Our industrial electrical system is of 3 phase power input viz. R, Y and B. Getting measurement of a parameter in all three phase simultaneously is more desired while deciding the load. The SYCON Multifunction Meter 9900 is made to fulfill this requirement. The Multi Function Meter 9900 consist of 20 characters 4 line LCD display for displaying parameters. This is the advanced version in Panel Meters with small volume and light weight, capable of displaying total of 41 electrical parameters. General Features Friendly user interface. Easy to install. RS-485 MODBUS Communication available
Frequency : 50Hz
...moreMotor Protection Relays
maximum demand controllers
A low cost version in MD controller series, 4300 SS proves to be a perfect value package. It comes with one trip output and one alarm output. The alarm and trip demand values are site settable
...moreMaximum Demand Controller
frequency relays
A frequency variations involves a change in frequency from the normally stable utility frequency of 50 hz 60hz. This may be caused by erratic operation of emergency generators or unstable frequency power sources. MFR 8801 reads the frquency. Displays it and compares it with set frequency and trip the deviceif frequency read is out of selected range. General Features Easy installation Low frequency Setting in range 35 Hz to 65Hz in step of 0.5Hz High frequency Setting in range 35HZ to 65Hz in step of 0.5Hz Trip Delay Time Setting in range of 1 to 60 sec in step of 1 sec.
...moreDigital Panel Meter
Digital Panel Meter are needed to monitor various electrical parameters. These can be used for three phase as well as single phase systems. Using this user can monitor the readings with the help of computer also. We also provide ‘Energy Monitoring Software’ for such applications.
...moreDigital Meters
Digital Earth Leakage Relay
Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. SYCON 770X Earth leakage Relay continuously detects the leakage current with the help of CBCT (Core Balance Current Transformer.) The CBCT is mounted externally. The current carrying cables (it may be 3 phase supply or 1 phase supply) are passed through the CBCT. CBCT detects the level of current and trip the device at set current & time. General Features Solid state Wide operating current range Low power consumption Variable current and time setting Ideal for compliance to I E rule 61-A
...moreDigital Ammeter
Friendly user interface. Easy to install. SYCON 9920 available with single input current SYCON 9923 available with three input current (For phase input current)
Accuracy : Class1 (±1digit).
...moreBe first to Rate
Rate ThisOpening Hours