Francis Turbine Test Rig
Get Price Quote
FRANCIS TURBINE TEST RIG JPTI’S Francis turbine 75 m.m. size to develop 1 Kw at 1250 R.P.M. with a flow of about 1000 L.P. M. at 10m. supply head, complete with rope brake arrangement,Orificemeter & pressure gauges provided to measure flow rate, and a set of dead weights etc. for conducting experiments in metric units.
Centrifugal Pump Test Rig
47,000 - 48,000 Per Piece
Best Deals from Test Rig
Vapour Absorption Test Rig
Get Price Quote
“Vapour Absorption Refrigerator” earlier known as “Electrolux” refrigerator is a self contained refrigerator working on absorption technology. In the absence of a compressor or pump, the circulation takes place by density difference. The system is pre-charged with three fluids namely water, ammonia and hydrogen. Hydrogen is used as an “inert gas” and does not undergo any phase change and heat transfer processes. Its purpose is to keep the pressure of the system constant. It uses an electrically operated generator, where, the ammonia vapours dissolved in water are separated and pure ammonia vapours enter the condenser. In the condenser, the high pressure vapours reject its latent heat to the surroundings and get liquefied. The liquid ammonia expands through expansion device where its pressure and temperature is reduced and cold low pressure vapour enters the evaporator where it absorbs heat from the space to be cooled and then vaporized ammonia absorbs in water. This strong solution then enters the generator and the cycle repeats. PRINCIPLE OF OPERATION Electrolux principle works on 3-fluid system. There is solution circulation pump. Total pressure is the same throughout the system. The third fluid remains mainly in the evaporator thus reducing partial pressure of refrigerant to enable it to evaporate at low pressure and hence low temperature. The schematic diagram of the Electrolux refrigerator working on NH3-H2O system with H2 as the third fluid is shown in figure. Liquid NH3 evaporates in the evaporator in the pressure of H2.Hydrogen is chosen as it is non –corrosive and insoluble in water. A thermosyphon bubble pump is used to lift the weak aqua from the generator to the separator. The discharge tube from the evaporator the generator is extended down below the liquid level in the generator. The bubbles rise and carry slugs of weak NH3-H2O solution into the separator. Two U-bends are provided as vapour- locks to prevent H2 from getting into the high side or solution circuit. Partial pressure of H2 provides the pressure difference of NH3 between the condenser and evaporator. Accordingly, we have: In condenser pure NH3 vapour pressure = Total pressure In evaporator NH3 vapour pressure = Total pressure - partial pressure H2 For example, consider the condenser temperature at 50 0C, and evaporator temperature as -15 0C. The corresponding vapour pressures of NH3 are: Condenser, Pk = 20.33bar; Evaporator outlet, Po2 = 2.6bar
Compressor Life Test Rig
Get Price Quote
We manufacture life test rigs that evaluate performance of the hermetic compressors under varying load conditions. Features: ⢠In-house electrical panel and data acquisition system design with Yokogawa NI DAQ systems and LabView DAQ programs for total automation. ⢠Multi refrigerant capabilities