Two Stage Transformer Oil Filtration Plant
Get Price Quote
Two Stage Transformer Oil Filtration Plant, offered by us, is suitable for degassing, dehydration and filtration of transformer oil under vacuum and achieve oil test results as per I.S standards. It basically works on heating, filtration and vacuum treatment. Our Transformer Oil Filtration Plant has flow rates ranging from 300 LPH to 12000 LPH. We manufacture different models of Transformer Oil Filtration Plant as per the requirements specified by the buyers. We offer Transformer Oil Filtration Plant for on-site filtration, castor mounted for factory and site filtration and stationery for filtration of collected oil. Optional items such as ionic reaction column (for acidity correction), Spirafuge for coarse separation, transformer evacuation system can also be offered with the product. Our 2-stage degassing plant has following components : Prefilter : Oil comes through Transformer/Tank via inlet valve to Pre-filter. It has powerful magnet located inside it. So, it adsorbs all magnetic impurities as well as provides protection to inlet pump which is positive displacement type gear pump. Heater Tank : Inlet pump delivers the oil straight towards the heater. Heater tank is designed for heating of oil through indirect type of heating. Heaters are suitably grouped to achieve power economy when oil quantity is less. Ionic Reaction Column : This part of machine is used to reduce the acidity of oil. We use activated alumina for the adsorption of acid particles when oil is passed over it. Filter Chamber : It has two layers of filters; one is 100 micron rating filter mesh & others are 1 micron rating filter cartridges distributed evenly all over the area. 100 micron mesh is used for increasing the life of filter cartridges as cartridges are to be replaced when choked. It reduces running cost of machine. Degassing Chamber : The function of this part is to remove moisture & entrapped gases in the oil. In these type of machines, degassing chamber is divided in 2 stages by siphon. in The first stage connected to vacuum pump, is used for removal of free moisture present in the oil. Second stage degassing chamber is connected to the Booster pump which in turn is connected to high capacity vacuum pump. In this stage, entrapped moisture & gases are removed. In degassing chamber, arrangements are made in such a way that thin film of oil is exposed to vacuum for maximum period of time with help of shower arrangements, knitmesh packings, etc. Outlet Pump : This pump is glandless centrifugal type. This pump takes of De-acidified, filtered & dehydrated oil back to the transformer/ tank. Safety Interlocks : If your inlet pump is not turned on, heaters will not get turned on. If by some means, level of oil in degassing chamber rises & in turn rises float, inlet pump is turned off & in turn are the heaters. Value-added services : If main supply is connected in reverse rotation, indicator will be glown on panel & no motor will start. Solenoid valves are provided in vacuum lines so as to avoid oil rise into trap when suddenly vacuum pump is stopped & airing is not done. By-pass connection is given in the machine so as to change the positions of hoses, without shutting down the machine.
Sewage Water Treatment Plant
400,000 - 5,000,000 Per piece
1 Number (MOQ)
package sewage treatment plant based on rbc technology to have smoother operation and the most economical running cost
Best Deals from Water Treatment Plant
Transformer Oil Filtration Plant
Get Price Quote
Transformer oil filtration plant are in flow rates from 300 LPH to 12000 LPH. Custom built plants can be provided as per customer’s specific requirement, such as more flow-rates. These plants work on low temperature, high vacuum principle. Plants mainly consist of heating, filtration and vacuum system. Heating system aids to the filtration and moisture removal. Filtration systems remove suspended particles down to 1 micron such as rust, dirt, scales, colloidal carbon etc. Vacuum Systems remove moisture (emulsified as well as dissolved) down to < 5 – 10 ppm depending on the working vacuum of the plant.
Transformer Oil Filtration Plant
Get Price Quote
Systems are in flow rates from 300 LPH to 12000 LPH. Custom built plants can be provided as per customer’s specific requirement, such as more flow-rates. These plants work on low temperature, high vacuum principle. Plants mainly consist of heating, filtration and vacuum system. Heating system aids to the filtration and moisture removal. Filtration systems remove suspended particles down to 1 micron such as rust, dirt, scales, colloidal carbon etc. Vacuum Systems remove moisture (emulsified as well as dissolved) down to < 5 – 10 ppm depending on the working vacuum of the plant.
Portable Oil Filtration Plant
400,000 Per Unit
1 Unit (MOQ)
commercial ro water purifiers
Get Price Quote
1 Piece (MOQ)
We are offering commercial ro water purifiers 250lph,500lph and onwards.
Water Treatment Plants
Get Price Quote
Water Treatment Plants, Water Purification Plant, water purifier membrane
Water Treatment Plant
Get Price Quote
Fastener, filter spare parts, Media Filters, RO System
Water Purifier
Get Price Quote
Kitchen Trolley, Mixer, Chimney, Gas Geyser, Gas Stove