Solar Panel Lightning Protection System
Get Price Quote
20 Piece (MOQ)
Unmanaged Ethernet Switches
1,000 Per Piece
Unmanaged ethernet switches eds-205208 series are entry-level industrial 5 and 8-port ethernet switches that support ieee 802.3802.3u802.3x with 10100m, fullhalf-duplex, mdimdix auto-sensing rj45 ports. The unmanaged ethernet switches eds-205208 switches are rated to operate at temperatures ranging from -10 to 60°c, and are rugged enough for any harsh industrial environment. the unmanaged ethernet switches eds-205208 can be easily installed on a din-rail as well as in distribution boxes. The din-rail mounting capability, wide operating temperature, and the ip30 housing with led indicators make the plug-and-play eds-205208 switches easy to use and reliable.
Best Deals from Electrical Circuit Breaker
Lighting Arrester Rod
Get Price Quote
Characteristics & Benefit Country Of Origin l First Indian made Advanced Safe Light-ning Protection Rod Technology l Based on a Hybrid Model which conforms to the latest ESE standard as per NFC & Corona Inhibiting Technology Central Main Rod | Based on the result of recent research it has been concluded that Blunt Tip is more efficient in real world conditions in increasing the efficiency of the system. Upward Streamer l Blunt tip increases the length of upward streamer as the construction of the system allows it to store the charge within it so as to release it in the most optimum possible way. SFCH | Side Flash Capture Head prevents damage to property and life trom side flashes Power Source l THOR SLPR doesnt require any input. Come pletely Self Reliant Coverage Area l Provides larger area tor interception of |ighthing Material Of Construction (SS 304 l SS 316) l Made of high quality stainless steel which allows the system to efficiently operate in all kinds of weather conditions. Corrosion Resistant Installation/Service Support I Direct Manutacturers Service Support for installation and Maintenance Certification l CPRI tested & certified tor both types (+ ,-) impulse Design Patent/ Intellectual Patent l The one & only lndian make brand of its category to get patent due to its unique combination of technology & design ApplicationsAll type of Industrial units, power plants, transmission towers, offices, residences, commercial structures, telecommunications towers, wind farms, power stations, mines and virtually every installation Certifications | Standards | ApprovalslSO 9001:2008 l OHSAS18001 I CPRI l RoHS | CEStandard Of Compliance : UNE 21186 Designed in accordance with NFC 17 102Working Principle of THOR LPRTHOR SLPR is designed in such a waythat the sum of its parts works in tandem to attract and capture lightning strikes in an efficientway. When the downward leader approaches the structure and creates an electricfield to enable free movement of charges, the internal design of THOR SLPR helps to increase the quantity of emitted charges by reducing and limiting corona in the initial stages of lightning. The charges stored in THOR SLPR will not be wasted in the developing stages of lightning as it is designed to provide zero surface area for corona to occur. Once THOR SLPR gets fully charged, a very powerful upward streamer with high charge density of longer length is released from THOR SLPR which couples with the downward leader from lightning, at a very high distance from the structure, which it is protecting. HenceTHOR SLPRis able to protecta largerarea. Recent research shows when lightning strikes any object, it creates secondary flashes. THOR Sl_PR is designed with SFCH which captures any secondary flashes that may occur during a lightning strike thus preventing these secondary flashes from causing damage‘THOR SLPR has been developed in such a way that it requires no maintenance and Works in alt types of atmospherlccondition. SLPR : Safe Llghning Protecflon Rod SFCH : Side Flash Capture HeadRadius Of Protection (Rp)The radius of protection is the distance between the point where you want to place the rod and the further pointfrom the structure or building we want to protect for calculating the radius of protection, It is very important to get the triggering advance time value of the device.Triggering Advance Time (Delta)The triggering advance time is defined as the difference in triggering time of an early streamer lightning rod and a simple tranklin rod obtained when both rods exposed in the same atmospheric and electrical condition A = TSR-TESE .v\/here,TSR = The mean triggering time ofthe upward leader of a simple lightning rod.TESE = The mean triggering time of the upward leader of a ESE lightning conductor.Calculation for Radius of ProtectionThe protection radius of an early streamer emission air terminal is calculated using the following equation Rp = \/2rh ~ h2 +Δ (2r + Δ )for h>-5m Δ= TriggringTime r(m) = 20m for L-1 = 30m for L-2 = 45m for L~3 = 60m for L-4 Installation Method For THOR Safe Lightning Protection Rod Unpack the THOR SLPR from the box Tighten the base coupler of THOR to the top of the mast (l\/last Coupler) Connect the down conductor to the side of the base coupler using the provided LN Key arrangement Erect the mast using toundation bolts to the top of the building, securely Run the down conductor along the length of the mast, and onward along the height of the building and connect it to the dedicated earthing tor THOR SLPR Attache A.L.l.C.E to the wall near the dedicated earthing pit at a convenient height (5 feet or eye level) Pass the down conductor through A.L.|.C.E before attaching it to the dedicated earthing tor THOR SLPR The down conductor needs to be attached to the structure by way of insulators and clamps every 1 metre for support. It is recommended to connect all the metal bodies present in the vicinity of THOR SLPR to prevent side flashes during a lightning strike. Provide a test link above A.L.l.C.E tor periodic maintenance and testing. Our Recommendations The mast should have a minimum length of 4.5 l 6 metre and should be constructed of FRP or GI / SS A,L.|.C.E should be installed at a height of 5 feet from the ground level (eye level) The down conductor should be a Single Core Insulated Flexible Copper Cable of 70 sqmm cross section minimum, or a Strip of Copper or G.l With a minimum cross section of 70 sdmm. The shortest possible path should be chosen for the down conductor. The THOR SLPR needs to be connected to its own dedicated tripodal earthing systern.
Electrical Switchgear
10,000 - 100,000 Per Cubic Meter
1 electrical Norisys Switch (MOQ)
aarti switchgear private limited engaged in supplying of superior quality of norisys switches cube series ca-304.15 that are efficient, reliable and durable..
Surge Protection Device
Get Price Quote
We offer Surge Protection Device. AC Surge Protection Devices, Coaxial Protection Devices, Data Line Surge Protection Devices, DC Surge Protection Devcies, etc. Besides, we are also a service provide of Cable Installation and Equipment for the Air Assisted Cable Installation
Air Circuit Breaker
Get Price Quote
The company has carved a niche as a Manufacturer and Supplier of Air Circuit Breaker based in Hyderabad (India). Also called the intelligent universal circuit breaker, the Air Circuit Breaker is mainly used in the low voltage distribution switchboard to control and protect the power distribution systems. The technical index of the Air Circuit Breaker reaches the international advanced standard of that kind of products in 1990s and conforms to criteria for low voltage breaker in IEC60947-2. Characteristics Of Air Circuit Breaker Highly reliable Excellent performance Safe design Efficient power distribution
Rocker Switches
5 Per Piece
LT Switchgear
Get Price Quote
We are offering l & t, siemens, lg, abb, hpl, megawin, schneider electric, general electric, crompton greaves, english electric company limited, sales & services.
Voltage Surge Suppressors
Get Price Quote
Class IClass B lightning arresters are mainly used in lightning protection zone (LPZ) 0 to 1, widely used in building entrance lines(such as distribution box), elevator, mineral, oil equipments, power transmission and so on. Class I lightning arresters adopt unique designed seal construction with multilayer spark gap, no spark emission outside the housing. Suitable for grounding system TN-C, TN-S, TT and IT. With working status indication window, and remote control contacts. High impulse discharge current, Iimp value is 25kA, 50kA -10350us.
legrand mcb
850 Per Piece
50 Piece (MOQ)
lt switch gear
Get Price Quote
Available in different current ratings with competitive price.
Gas Insulated Switchgear
Get Price Quote
We provide the Switchgears up to 132kv substation applications. We carry out the turn key projects in this area from the system design, engineering documentation, procurement, installation & commissioning. In all the above areas, we take up the long term maintenance contracts for the systems and equipments supplied by us. We deal with ILJIN make GIS of 33kv and 132kv voltage level.
Switchgear Panel
3,000 Per Piece
Legrand Circuit Breaker
110 Per Piece
Automatic Transfer Switch
Get Price Quote
Salient Features Automatic start/stop operation of DG on mains failure Overload tripping (optional) with inverse curve logic Automatic transfer switch are provided with fire alarm / external fault trip feature Inbuilt control switch for selecting auto/manual mode Automatic transfer switch have high capacity to withstand short circuit Optional RS485 communication and cloud Applications Monitor real-time system voltage and frequency Monitor source healthiness and output for both Source Wide range of motor operating voltage from 150VAC – 285V AC Automatic transfer switch for commercial centers, manufacturing, medical facilities,and data centers.
Electrical Surge Protector
Get Price Quote
MCB Switch Gear
100 Per Piece
Ethernet Switch
Get Price Quote
Ethernet Switch
8,999 Per Piece
10 Piece (MOQ)
Changeover Switches
Get Price Quote
Allows switching between main supply and generator in emergencies.These switches are used for both industrial and commercial purpose.
compact ring main unit
Get Price Quote
Standard: IEC 60694, 60265, 60129, 60420, 602271-100/200 &60255 Features • Both indoor and outdoor type of execution available. • Arc interruption is in vacuum • The switchgear and bus bar with ring switches are sealed in a sf6 insulated stainless steel gas tank • Robotic welding of gas tank ensures leak free operation • Spring operated and Magnetic Actuator versions available • Tee off can be motorized and suitable for remote operating • Remote communication is facilitated through SCADA system • Uses puffer principle for normal current breaking of ring
Surge Protection Device
Get Price Quote
Residual Current Circuit Breaker
Get Price Quote
Vacuum Interrupter
Get Price Quote
We are the suppliers of Vacuum Interrupters up to 33kV class. And current rating from 630A - 2500A., 13.1kA - 40 KA SPARE APPLICATIONS.
Load Break Switches
Get Price Quote
Load Break Switches, Vacuum Circuit Breaker, Electrical Switch Gears
Gas Insulated Switchgear
Get Price Quote
Gas Insulated Switchgear, Electrical Panels, MOTOR CONTROL CENTERS
Belt Sway Switch
2,000 - 3,000 Per Piece
Ball Bush bearing options for roller & cam shafts Wide over travel of the roller permissible without damaging the switch element Robust spring to absorb impact from belt and effect quick self resetting Grade of protection IP-65. Standard contact Rating -10 amp.
control gears
Get Price Quote
control gears, Switch Gears, Measuring Instruments, Lighting Products
Remote Control Switches
Get Price Quote
Remote Control Switches
temperature switches
Get Price Quote
temperature switches, Pressure Gauges, Flow Meters, Gauge Cock