y-strainer
Honeywell Y-type strainer is widely used in water application and is used for protecting valve and other equipments from scrap and impurities in the system. Features: Ductile iron body with epoxy coating Stainless steel filter screen
Size Range : DN50 to DN600
...moreVariable Air Volume Box
Variable Air Volume (VAV) Boxes are required to control air supply as per the requirement in an air distribution network of air flow in a particular zone. VAV Boxes are used very frequently in office space, commercial towers, conference rooms & control area to control temperature & try to achieve a particular set point given to its thermostat. VAV Boxes by varying airflow can control various parameters like temperature, CO2 level, positive differential pressure, depending upon its application. It also attains substantial energy saving by blocking access air into the duct & hence in-turn low rpms of AHU fans, unlike constant air volume system which is not capable of achieving high energy efficiency. NinthWave is associated with Honeywell Automation to bring out the best quality Variable Air Volume system to its customers. WE became proud ‘exclusive channel partners for VAV system’ of Honeywell Automation for complete country in year 2014. We provide Pressure Independent type Variable air volume boxes, factory fitted with a microprocessor DDC controller, damper, damper actuator, cross flow velocity sensor with differential pressure transmitter, thermostat and in-built step down transformer. VAV boxes are calibrated in factory & undergo Honeywell’s stringent quality check tests before being shipped out of factory. We can also customize VAV boxes as per the requirement of customer like, single skinned, double skinned, by-pass, multi leaf, with heating element etc. VAV controller comes with BACNet® MS/TP communication standard, which is widely accepted for third party integration across the country. We also provide tested integrators for VAV integration. In past years we have successfully commissioned VAV system at so many prestigious multi-national client offices across the country, catering to their customized requirements. Applications successfully commissioned are briefed below. Zone Temperature Application This is the most common type of application, required to control temperature by varying air flow. The most critical of them were heating & cooling application, where air temperature changes as per the weather condition, & hence VAV operation also reversed to achieve a set point. Our technical team has mastered these applications to ensure proper operation of the system. Fresh Air/ Ventilation (Demand Control Ventilation) Application In Demand Control Ventilation, a VAV operates to limit & measure the air flow required to maintain a CO2 differential level in a particular zone. A high CO2 level can cause lower work efficiency of the work force. Also access fresh air intake in an AHU can decrease its energy efficiency. In order to control an optimum level of CO2 differential level, a Variable Air Volume Box finds its application, it measures CO2 level & modulate accordingly to maintain a CO2 level inside a work space. We have commissioned systems having such requirement across the country successfully. Our controllers are fully compatible to maintain VOC level, rH level etc. to provide a controlled environment. Differential Pressure Application We have also come across differential pressure application, where a VAV is placed in return duct, & it allows maintaining a higher pressure in the controlled area. This application is generally used in controlled environment like clean room, drug formulation chambers, storage cabins, Server rooms etc. Applying VAV system, an efficient dust free system can be provided by maintaining a positive pressure inside the zone. We have undertaken these critical application & successfully commissioned them. VAV Box CFM Range: We offer an extensive range of CFMs from 62 cfm to 8000 cfm
Material : Mild Steel
Application : Industrial Use
Color : Silver
Warranty : 1year,1 Year
...moreUltrasonic Clamp-on Flow Meter
Details : Non-intrusive. No risk of contamination or leakage Easy installation. No pipe cutting, no hole drilling. Save installation cost Can be easily moved from one location to another For pipe size DN25 ~ DN6,000 (1”~240”) Ultrasonic flow measurement is among the best & most accurate technology available these days. It is widely accepted & prominently used across the industries due to its non-cohesive nature with the flow media. It is also non-effected in high magnetic field zones, where other technologies like electromagnetic & Boltzmann’s turbine technologies might have a challenge. Our Shenitech ultrasonic flow meters work on Transit time principle which ensures high accuracy. Our ultrasonic flow meters are used not only for domestic water application but also in dirty water having high TDS, in Sewerage treatment & effluent treatment application. Transit time principle is annotated as below. “ It is the time difference taken by two UH frequency pulses to reach the diametrically opposite ends of the pipe, which is related to the velocity of the fluid media inside pipe in direct proportion ” Suppose ‘T1’ is the time taken by pulse to travel downstream to the flow of media & ‘T2’ is the time take by the pulse to travel upstream of the flow media moving unidirectional with velocity ‘v’ , then time difference ‘δT’ is related to velocity as (T2 – T1) = δT Or δT α v Or δT = k * v Or δT/k = v Cross section area of pipe is ‘A’ Then Flow rate ‘Q’ can be calculated as Q=v*A We can offer inline type as well as clamp-on and insertion type sensors, depending upon the applications’ requirement. Our flow meters offer all standard signal outputs like analog outputs (4- 20 mA or 0-10 VDC), Modbus over RS-485, M-Bus etc. which is widely accepted for third party integration. Benefits & Features : Low maintenance as no moving parts High Accuracy as high as ± 1% OIML R49 standard. CE Approval Low pressure drop Tamper Proof Design Low Cost Over long run We have all types of sensors option available as far as mounting is considered. The sensor selection is generally depend upon the application & site conditions. We recommend to take our expert advice before making selection of appropriate sensor.
Material : Stainless Steel
Packaging Type : Carton Box
Display : Digital
Operating Type : Manual
Usage : Water And Chemicals
Specialities : Lorawan Compatible, Accuracy
...moreTemperature Sensor
10,000 Per Piece
Type : Universal Thermometer
Feature : Digital
Temperature Range : -20 Degree C
...morepropeller fan
10,000 Per Piece
Material : Metal
Thickness : 10-15mm
Grade : ASME, ASTM, DIN
Feature : Accuracy Durable, Dimensional, High Quality
No Of Blade : 4
Brand Name : Transmonk
...moreProgrammable Thermostat
10,000 Per Piece
Display Type : LCD
Brand Name : Honeywell
Pressure Reducing Valve
The PRV valve protects domestic, commercial and industrial applications against excessive water supply pressure. It reduces both water consumption and noise from water hammer, while minimising over pressure damage. The set outlet pressure can be maintained even when there are wide inlet pressure fluctuations. A drop tight seal means outlet water pressure will not increase when there is no flow. It has been awarded the Waterwise Marque. Features : Outlet pressure set by turning the adjustment knob Set pressure directly indicated on the set point scale Adjustment spring not in contact with wholesome water Valve insert is of high quality synthetic material and can be fully exchanged Integral fine filter (160 microns) Available without fittings Light weight Reliable and proven Drop tight max. 16 bar with clear filter bowl or max. 25 bar with brass filter bowl inlet pressure 1.5 - 6 bar outlet pressure Available with pressure gauge Options: 1/2" and 3/4" Female BSP connections 15mm and 22mm connections
Material : Metal
Application : Water Fitting
Feature : Blow-Out-Proof, Durable
Pressure : High Pressure
Number Of Way : 3way
...morePressure Independent Control Valve
Details : Pressure independent control valves balance the system at every point over the range of the control valve within 5% accuracy Control flow exactly at all load conditions, not just at design conditions Improved control and performance helps extend actuator life expectancy High Turn-Down Ratio/Equal Percentage Flow results in linear heat transfer for optimal control. The characterized insert is integral to the ball, resulting in longer service life and higher differential pressure capabilities. Less torque is needed, so you can use lower-cost, low-torque actuators on larger pipe sizes No Cv calculation required - just pick the valve that matches the flow requirements - Flow range of 1 to 95 gpm Field serviceable stem allows valve to be serviced in the field rather than cut from the pipe Optional test ports facilitate system set-up for balancing report Manual override to control valve during installation or in the event of power failure Full range of sizes from 1/2" to 6" 5-year actuator warranty
Packaging Type : Carton
Material : Metal
Media : Water
...moreNon Returnable Valve
The Dual Plate Check Valves is designed for Chilled & Hot Water for purpose non-return valve that is stronger, lighter in weight and smaller in size as compared to other Check valve. Features: Wide Size range (DN50…DN300) Cast iron Body Lapped Ductile Iron disc Wafer type and flange type Connection
...moreMotorised Butterfly Valve
Large capacity. Small Dimensions. Offer two-position or modulating control of chilled and hot water, cooling tower systems, and thermal storage systems Pipe sizes from 2 - 20" for both 2-Way and 3-Way applications Floating, modulating, 2-position direct coupled actuators and industrial-grade electric actuators; high and low pressure spring and non-spring return pneumatic actuators Lug body Manual shut-off valves for end-of-line service Corrosion resistant coating Heavy duty, corrosion-resistant top bushing, located in the upper journal, absorbs actuator side thrust Each valve is factory tested to 110% of specified pressure rating
Material : Cast Iron
Feature : Casting Approved, Durable
Technics : Hard Sealing
Port Size : 2cm -50cm, 5cm-60cm
Size : 1.1/2inch, 1/2inch, 2inch
Number Of Way : 2way, 3way
...moreManual Butterfly Valve
The Manual Butterfly Valves is designed for Chilled & Hot Water to be operated by Hand lever or Gear Box Features : Wide Size range (DN40…DN900) Operated by Lever or Gear Box. 90 deg opening/closing operation. Cast iron Body with powder coating. Epoxy Coated Ductile Iron disc. Wafer type Connection
Disc Material : Epoxy Coated Ductile Iron Disc
...moreManual Ball Valve
Features : Forged Brass Body Chrome Plated Ball Standard Port and Full Port Design
Feature : Casting Approved, Durable, Investment Casting
Media : Water
Number Of Way : 2way, 3way
...moreManual Balancing Valve
The Balancing Valves is designed for double regulating, control and shut off valve with built-in pressure drop measuring facility. We have a wide range from 15mm to 300mm. It is divided in two parts, 15mm to 40mm and 50mm to 300mm as below, For 15mm to 40mm, Application : The hydronic balance is a significant requirement for the efficient operation of a hydronic heating or cooling installation. In an unbalanced system under or over provision of hot water to individual radiators or circuits can occur. Apart from the correct selection of radiator valves, regulation of individual circuits is also necessary and in some cases, such as in DIN 18 380, VOB part C, required by national standards. The Valve is a variable orifice double-regulating balancing valve for the return with additional functions shutoff, draining and filling. It can be upgraded to an automatic balancing valve - even after the system has been taken into commission and under system pressure. Features : Quick and easy measuring with SafeConTM measuring connections Dimensions DN15 to DN40 can be retrofitted with a Kombi-Diaphragm Unit High accuracy of pre-setting because of individual adjustment Robust valve body made of corrosion resistant red bronze Available in sizes up to DN80 Visible pre-setting dial with concealed pre-setting wheel Maintenance free spindle with double O-ring sealing’s PTFE-seat sealing
...moreinsertion flow meter
Details : Excellent long-term stability Better accuracy than clamp-on Better signal strength, thus, better performance than clamp-on when liquid has some solids For pipe size ≥DN80 (3”) Ultrasonic flow measurement is among the best & most accurate technology available these days. It is widely accepted & prominently used across the industries due to its non-cohesive nature with the flow media. It is also non-effected in high magnetic field zones, where other technologies like electromagnetic & Boltzmann’s turbine technologies might have a challenge. Our Shenitech ultrasonic flow meters work on Transit time principle which ensures high accuracy. Our ultrasonic flow meters are used not only for domestic water application but also in dirty water having high TDS, in Sewerage treatment & effluent treatment application. Transit time principle is annotated as below. “ It is the time difference taken by two UH frequency pulses to reach the diametrically opposite ends of the pipe, which is related to the velocity of the fluid media inside pipe in direct proportion ” Suppose ‘T1’ is the time taken by pulse to travel downstream to the flow of media & ‘T2’ is the time take by the pulse to travel upstream of the flow media moving unidirectional with velocity ‘v’ , then time difference ‘δT’ is related to velocity as (T2 – T1) = δT Or δT α v Or δT = k * v Or δT/k = v Cross section area of pipe is ‘A’ Then Flow rate ‘Q’ can be calculated as Q=v*A We can offer inline type as well as clamp-on and insertion type sensors, depending upon the applications’ requirement. Our flow meters offer all standard signal outputs like analog outputs (4- 20 mA or 0-10 VDC), Modbus over RS-485, M-Bus etc. which is widely accepted for third party integration. Benefits & Features : Low maintenance as no moving parts High Accuracy as high as ± 1% OIML R49 standard. CE Approval Low pressure drop Tamper Proof Design Low Cost Over long run We have all types of sensors option available as far as mounting is considered. The sensor selection is generally depend upon the application & site conditions. We recommend to take our expert advice before making selection of appropriate sensor.
Display : Digital
...moreInline Ultrasonic BTU Meter
BTU meters are used on chiller lines to measure the energy consumed by the chillers in the cooling process. Our BTU meters are constantly used in projects and recommended by various consultants and BMS providers across the country. Shenitech ST-280T BTU meters are based on Ultrasonic Transit Time Technology. These BTU meters assure Class-2 accuracy and have a tamper-proof model as per the energy norms in various countries. These BTU meters have an in-built battery i.e. no hassles of power supply on the site. Battery back-up lasts for 6 years. Since there is no moving part in the sensor assembly these meters are maintenance free and hence has high reliability. Unmatched Advatages of Shenitech BTU meters We have an entire range of ultrasonic flowmeter from 15mm to Line sizes more than 700mm and customized for higher line sizes as per your requirements. Our meters can detect a very high capacity of flow. Because of the high flow capacity, we need a lower size meter for a certain flow rate. - For example: 100mm line size might require our 65mm flow meter. This enables cost saving and also proper sizing of the meter. All our meters are wet calibrated where the temperature and flow sensor are calibrated together and we give a calibration certificate with each and every meter. All our meters have an inbuilt battery backup – guaranteed for a minimum of 6 years.Hence no hassels of giving rthe power supply and spending unnecessary cabling and cable laying cost. No reflector used for detection of flow. This ensure that meters are very robust and don’t have any problems even after years of operation. This ensures efficiency of meter and maintenance free years of operation. Single point source for meters, hardware for interconnectivity (M-Bus) and software for billing and meter reading. This ensures zero dependence on a third party. Also we ensure that the system is up and running at all times. Tamper proof design---ensures no tampering in the final bill 2 years international warranty on all the products
Material : Aluminium
Certification : CE Certified
Feature : Durable, High Accuracy
Display Type : Analog, Digital
Rated Power : 100W, 200W
Warranty : 1Years
...moreInline Flow Meter
Details : Excellent long-term stability Best accuracy among the three transducer types Flowmeter is pre-programmed in factory, thus, it is a simple plug and play device For pipe size DN10~DN500 (3/8”~20”) Ultrasonic flow measurement is among the best & most accurate technology available these days. It is widely accepted & prominently used across the industries due to its non-cohesive nature with the flow media. It is also non-effected in high magnetic field zones, where other technologies like electromagnetic & Boltzmann’s turbine technologies might have a challenge. Our Shenitech ultrasonic flow meters work on Transit time principle which ensures high accuracy. Our ultrasonic flow meters are used not only for domestic water application but also in dirty water having high TDS, in Sewerage treatment & effluent treatment application. Transit time principle is annotated as below. “ It is the time difference taken by two UH frequency pulses to reach the diametrically opposite ends of the pipe, which is related to the velocity of the fluid media inside pipe in direct proportion ” Suppose ‘T1’ is the time taken by pulse to travel downstream to the flow of media & ‘T2’ is the time take by the pulse to travel upstream of the flow media moving unidirectional with velocity ‘v’ , then time difference ‘δT’ is related to velocity as (T2 – T1) = δT Or δT α v Or δT = k * v Or δT/k = v Cross section area of pipe is ‘A’ Then Flow rate ‘Q’ can be calculated as Q=v*A We can offer inline type as well as clamp-on and insertion type sensors, depending upon the applications’ requirement. Our flow meters offer all standard signal outputs like analog outputs (4- 20 mA or 0-10 VDC), Modbus over RS-485, M-Bus etc. which is widely accepted for third party integration. Benefits & Features : Low maintenance as no moving parts High Accuracy as high as ± 1% OIML R49 standard. CE Approval Low pressure drop Tamper Proof Design Low Cost Over long run We have all types of sensors option available as far as mounting is considered. The sensor selection is generally depend upon the application & site conditions. We recommend to take our expert advice before making selection of appropriate sensor.
Material : Cast Iron
Packaging Type : Packed In Corrugated Boxes
Driven Type : Electric
Accuracy : 1.0% Of Reading At Rates > 0.5m/s 0.005 M/s Of Reading At Rates < 0.5m/s
...moreGlobe Valve
Details : Available in threaded (1/2" - 3") or flanged (2-1/2" - 6") 2-Way and 3-Way Equal percentage flow Stainless steel stem and trim 2-position or precision modulating control of hot and chilled water or steam Accurate positioning with equal percentage and linear flow characteristics to ensure state-of-the-art temperature control
Packaging Type : Carton
Material : Metal
Finishing : Coated
...moreFCU Valve
High pressure zone valves used to control the flow of hot or chilled water in unitary equipment Used in conjunction with VU Fan Coil Actuators Maximum static water pressure: 300 psig Ambient temp range 34 - 104°F Patented ball seal provides long service life, soft close-off No cartridges 3-Way are mixing only Quick opening/soft closing for optimal 2-position control Compact construction for easy installation Fits under the cover of most baseboards Convectors with actuator fitted to body
Material : Mild Steel
Port Size : Multisizes
...moreExhaust Disc Valve
5,000 Per Piece
Packaging Type : Carton
Material : Plastic
Finishing : Coated
Warranty : 1 Year
Brand Name : Transmonk
...moreelectronic thermostat
7,000 Per Piece
Brand Name : Honeywell
Accuracy : +/-0.5'C
Temperature Range : +5'C
...moreDamper Actuator
7,000 Per Piece
Material : Forged
Power Supply : 220V
Certificate : CE Certified
...moreConstant Airflow Regulator
5,000 Per Piece
Material : Plastic
Application : Electricity Use
Feature : Accurate Reading, Longer Service Life
Automatic Grade : Manual
...moreco2 sensor
Material : Plastic
Application : Carbon Dioxide Gas Detector
Weight : 150gm, 200gm
Power Source : Battery
Warranty : 1yr
Mounting Type : Wall Mounting
Brand Name : Honeywell
...moreClamp-on Ultrasonic BTU Meter
The STUF 300R ultrasonic thermal energy meter provides abundant capabilities for accurate thermal energy measurement of a liquid-based thermal energy production / transferring system. It is the 3rd generation energy meter from Shenitech. Compared to its predecessors, the 3rd generation offers better performance and a richer feature set, all at a lower price. The STUF 300R system is consisted of a high performance ultrasonic flowmeter EF10 and a pair of standard PT100 temperature sensors. The ultrasonic flowmeter is based on our cutting-edge clamp-on flow measurement technology, which is capable of measuring the flow from outside of a pipe accurately and reliably. Due to the non-intrusive nature of this technology, there is no pipe cutting, no moving parts, no pressure drop, no leaks and no risk of contamination. Besides, the installation is simple and requires no special skills or tools. The two PT100 sensors, which could be either insertion type or surface-mounting type, are used to measure the temperature of the supply flow and the return flow. The energy consumption rate is then calculated based on the temperature difference and the measured flowrate. A built-in energy totalizer is used to accumulate the amount of energy delivered. STUF 300R provides versatile input/output interfaces, such as isolated digital outputs, relay output, batch control, alarm, 4-20mA output. In addition, the built-in isolated RS-485 port with surge protection and MODBUS support makes remote energy monitoring and energy meter networking easy and reliable. Other output modules, such as BACnet module, Ethernet module, GSM/GPRS wireless module, RF module and more, can be added to the standard package. STUF 300R is an ideal choice for improving HVAC, energy production and building energy efficiency in terms of heating, cooling ventilation and air-conditioning. Advantages : Non-intrusive thermal energy/BTU measurement Easy and economical installation; no pipe work required No moving parts to wear and tear; no maintenance required Industrial grade temperature sensors and ultrasonic sensors for improved robustness Paired PT100 RTD sensors and ultrasonic transducers for improved accuracy Suitable for pure liquids and liquids with some particles; no dependency on conductivity Suitable for all commonly used pipes Bi-directional flowmeasurement Seamless integration of temperature and flow so as to deliver a complete energy metering solution High-performance; abundant input/output features, such as 4-20mA, relay, alarm, task scheduler, batch controller and more Totalizers for flow, energy, daily energy and monthly energy Large data logger for recording multiple variables (optional) Communication: RS485/MODBUS. Optional GPRS, GSM, RF wireless Compatible with the uGalaxy telemetry system for centralized energy distribution management Conclusions : The entire installation and system tuning was completed within two days time, therefore a quick andeconomical installation. This is only possible with non-intrusive clamp-on ultrasonic technology. The fact that the size of the pipe was as large as 24 , one can only imagine how expensive and labor intensive it would have been to use another type of technology, i.e., mechanical flowmeter or magnetic flowmeter. STUF 300R BTU meter resulted with saving the customer major installation costs and quickly delivered most favorable results. In summary, the benefits of the Shenitech Metering STUF 300R energy metering system include: Non-intrusive installation thereby significantly saving money and time, in particular for large size pipes No moving parts, thus, almost no maintenance, thereby savingmaintenance costs Accurate flow and BTU measurement improves chiller plant control Real-time data and balancing information to improve system efficiency Continuous monitoring of flow, temperature, and energy transportation guarantees system performance along with providing alarm for potential risk or energy leakage Equipment : Shenitech Metering Clamp-on Wall-mount Ultrasonic Thermal Energy Meter, STUF 300R-C.
Material : Aluminium, Stainless Steel
Certification : CE Certified
Feature : Durable, High Accuracy
Display Type : Analog, Digital
Warranty : 1Years
...moreVariable Air Volume Annual Maintenance Service
Ninth Wave has launched a new initiative of refurbishing VAV equipment and systems within its service division. A comprehensive package which includes initial survey, VAV unit validation, report and recommendations, followed on, if required, by on-site rectification, modernisation and installation. With this single point responsibility, all work can be undertaken to suit the clients’ specific requirements bearing in mind that very often the offices are still occupied. Variable Air Volume Systems Currently available air distribution components, controls, and design strategies offer much more efficient designs than those installed and operating in many existing buildings. Today’s VAV systems can handle changing load requirements by varying the amount of heated or cooled air circulated to the conditioned space in response to varying heating or cooling loads. This reduces fan power requirements, which saves energy and costs. VAV-systems work either by opening or closing dampers or by modulating the airflow through mixing boxes powered by VAV fans as loads in various zones of the building change. How it Works: If, for example, more cooling in an area is required, the damper to that area is opened wider, increasing the flow of cold air until the desired temperature is reached. As the damper opens, static pressure in the duct drops, signaling the fan to increase air delivery. Conversely in this same example, if an area is too cool, the damper is slowly closed, reducing the flow of cold air. Variable-speed drives (VSDs): Used in combination with variable-speed drives (VSDs), this reduction in flow results in a reductionin the fan power needed, saving energy. Converting an existing constant-volume system to a VAV system is a popular option for many building owners, because it allows the system to turn itself down in response to changing demand. VAV Terminal units: Variable Air Volume terminal units regulate the flow of conditioned supply-air into occupied spaces, to assure that comfortable temperature levels are maintained.
...moreBTU Meter Annual Maintenance Service
Ninth Wave Technologies is one of the best BTU Meter Annual Maintenance Service provider in Hyderabad, Telangana. We are endowed with advanced equipment traceable to national standards and give dependable services. We have a group of enthusiastic, technically qualified, proficient Engineers & Technicians. Right from the inception of our company we are Quality Conscious and bring 100% satisfaction among our clients. We maintain our service’s quality standard. We always study, evaluate and adopt up-to-the-minute techniques to improve our quality of services. Our BTU meter annual maintenance services are highly affordable and dependable with a quality standard conforming to National & International Standards. We are available to call anytime.
...morebuilding management solutions
Building management solutions is an important monitoring & controlling system in any Building Automation System. It monitors & controls various utilities such as UPS system, Firefighting system, Alarm & Control System, VAV system, VRV system so on & so forth. Monitoring system like lift pressurization system & Stairwell Pressurization system, which are vital for safe passage of residents & occupants, in case of fire hazards. Also Variable Air Volume system control for both heating & cooling applications, is a typical application in any building automation software. At NinthWave , we are associated with Honeywell Building Automation, which provide prerequisite field & supervisory DDC (Direct Digital Control) controllers, as well as field sensors, necessary to monitor & control an even based on the inputs from these field sensors. We Apply A 3 Step Top-Down Approach In Providing A Feasible Solution For Any Automation Application Analyze the requirement: Once any system requirement is received our BMS team analyse the requirement of the system, & dissect the requisites to the minute level. This helps in better understanding of the application of the system & functionality of the system. Selection of the Controllers & Field sensors : After understanding the needed operation thoroughly, we look into the selection of the controllers & sensors, which would suffice to complete the required functions in a proper & efficient manner. Compatibility of sensors & DDC Controllers with respect to technical specifications is also taken into account, which diminish any chances of problems at later stage. Datasheets, Drawing, User Graphics : Once hardware selection is done, we communicate the same in comprehensible format to our customer, with appropriate drawings, datasheets & a pattern of User graphics. We have also undertaken various other process automation jobs like water flow control automation, pump automation & other customized automation solutions in various industries.
...moreFlow Metering Solutions
Water, Air & Steam are precious resources for a process plant & their consumption is critical, as they are important for various processes in HVAC, Food & Beverages, cement, automobile, chemicals etc. Production of these utilities is very expensive and an overhead to the companies. In order to maintain the efficient utilization of these utilities, continuous monitoring & control is required, so that the resources can be used effectively. Controlling of these resources is a big challenge, which every utility plant faces every day. For those having hassles in measuring & control of these resources, NinthWave comes with complete package products & solutions for them. We also ask our customers for their technical requirement & customize the solution which suits their requirement. With our solutions, client is not only able to control the consumption of these utilities in a particular section of a plant but also can chart out the daily, monthly usage pattern of the utility in that section. This data can further be utilized in planning various plant related activities as well as effective & efficient utilization of these resources in any industry. Customized Solutions Offered Are As Follows : Water flow Monitoring & Control The water consumption pattern will help in controlling the wastage of this resource, as well as can be billed to any customer for the monthly consumption. Compressed Air flow measurement & Control It is a universal fact that 15% of electricity is used in producing clean compressed air in any plant. By using this solution, consumption can be monitored, as well as air line ruptures can be traced, & hence wastage of air can be minimized which in turn will minimize the overall electricity bills. Solution can also give a brief idea about the health of air compressor plant. Steam flow monitoring & Control Boilers are the heart & steam is the blood in any process industry. To keep them healthy, we need to monitor steam flow consumption in different parts of a plant. It keeps the efficiency of boiler system high & put a check on its fuel bills.
...moreHeat Metering Solutions
BTU Meters or heat meters are used very frequently in HVAC, Food & Beverage, Automobile university & other process plants to measure chilling unit efficiency. BTU Meter or Heat Meters are used to measure the heat consumption of an Air Handler Unit in commercial buildings, Hotels, IT Parks & Malls etc. Heat Metering is a way to generate a legitimate bills based on the cooling consumption of a tenant. The other billing methods based on PSFT (per square feet), is generally getting obsolete, as the consumption of Air Handler Unit varies depending upon the heat load variation. BTU billing is critical as it is complex to understand that what to bill, & how to bill. But under Ninth wave’s expert supervision, it has become easier for a biller or building owner to understand the technicality related to Heat Metering billing. Heat Metering system once installed makes everyday life of a maintenance engineer easy, as by looking a single screen, he will be able to find out where exactly is problem & can plan service activities accordingly. NinthWave provides a complete one stop solution for Heat Metering, right from BTU Meters, Integrators, Billing Software . Our expert team can also design or customize a solution based upon the requirement of a customer. Our billing software when integrated with the BTU Meter units can deliver the legitimate bills directly to the customer. It also checks current status of a meter & can find out if meter is having any technical issues. It shows the current consumption values of every individual meter, like flow (m3/hr), Supply water temperature (oC), Return water Temperature (oC), Current heat load (KW), etc. By deducing the data from billing pattern & chilled water consumption, it becomes easier for an engineer to plan maintenance activities & also can achieve higher savings in electricity bills, by running Chillers in a more efficient manner.
...morewater treatment solutions
Water is a critical & important resource for any industry. Water needs to be treated before it is fed into the closed loop water circuit & hence measurement of critical parameter like pH, conductivity, Total Dissolved solutes etc. is required to control the quality of water & prevent scaling & internal rusting of pipe. NinthWave is a one stop complete solution provider for the requirements related to the measurement & treatment of water. We also do customization as per the customer’s requirement, like automation of chemical dosing to maintain pH, conductivity, Hardness in water, audio-visual alarm system for water quality & start-stop a process in case water quality is not upto the mark. Polluted water is a gigantic threat to the environment as it can pollute water tables & hence can cause several diseases to the society. Waste water should be treated before being sent out of a plant to city severs, or used for gardening or cultivation as per the pollution control board guidelines. It is hence a social responsibility & imperative to treat waste water & have a record of water parameters, which is generally demanded & checked by Environmental bodies time to time. A monitoring system needs to be in place, so that the complete water treatment plant can be controlled from a single place. We can provide complete package solution for waste water treatment right from different sensors like pH, Conductivity, Chlorine, TDS, Turbidity, BOD & COD analyzers etc. to control panels & software to monitor graphically the quality of water.
...moreBTU Meter Calibration Service
Ninth Wave Technologies is one of the best BTU Meter Annual Maintenance Service provider. We are equipped with sophisticated master instruments to provide excellent BTU Caliberation service in Hyderabad, Telangana. Our equipment is traceable to National Standards. We are supported by a group of enthusiastic, technically qualified, trained Engineers & Technicians. Right from the beginning we are Quality Conscious and maintain our service’s quality standard through National & International Standards. So we capably are into this process to provide total customer satisfaction. We always study, assess and adopt modern techniques to improve our quality of services. Contact us now for affordable and dependable services.
...moreBe first to Rate
Rate This