Phase Identifier with Unlimited range
Get Price Quote
Identify or trace the HV or LV phases at any point of the electrical distribution networks (substations, lines, LV networks, etc.) Phase Identifier with Unlimited range BT-HT USE : The FC4000 makes it possible to identify or trace the HV or LV phases at any point of the electrical distribution networks (substations, lines, LV networks, etc.) from a central reference.The network remains in its normal operating scheme and energized.The FC4000 can prepare accurately and in real time all operations requiring perfect knowledge of the phases:– Preparation work– setting up recharge,– setting service processors. CHARACTERISTICS : The reference unitPlaced permanently in a position, it is accessible by conventional telephone CPR.It includes:– A tag containing the antenna and GPS receiver for accurate timing measurements.– A housing containing the measurement and communication electronics.On the back side is all the connections. This housing can be attached to a relay board or integrated into a 19 “4U rack.On the front panel are all function, power, GPS synchronization indicators, presence of reference voltage 1 and 2 and telephone line socket.The mobile unit:It consists of a bag “repeater” containing all communication and measuring elements.The GPS mobile tag (precise synchronization of measurements).The mobile phone (communication with the reference).• Intelligent SensorOnce on, all the functions are automatic and without interpretation.It displays the phase index.It automatically recognizes the following situations:direct voltage phase / earth of the LV network, the resulting tensions capacitive dividers HTA cells.The signals coming from the sensor for the bare networks HT. Usable on open stations and aerial HTA networks, it is autonomous and works only on contact.• Reference Unit:– voltage references from 50 to 250 Vrms. Power consumption to 1 500 measurements.• Sensor for bare MV networks:– operating voltages phase / earth 2.5 to 30 kV.– infrared communication distance max. 20 m, beam diameter at 6 m: 1 m; Contact measurement.– Automatic start-up by presence of voltage.– automatic cut-off when the voltage is removed.– internal power supply by battery 9V autonomy> to 1 500 measurements.– fixation by standard notched tip. MORE PRODUCT: Profit for the phase identification with a central reference:– better planning of distribution networks and better economic management of their developments.– Reduction or postponement of investments (eg HV / LV transformers overloaded prematurely due to poor distribution of single-phase loads).– A reduction in the operating and intervention costs: planned and knowingly implemented intervention, for example additional work durations caused by the lack of prior knowledge of existing indices in an installation.– Reduction of customer recharge times (connection of generators).– Better security of goods and people.– Compliance and installation of visual markings on electrical installations.
Multi-Rotor Power Distribution Board
Get Price Quote
this handy power distribution board has the same foot print as our Multi-rotor control boards and is the ultimate solution for tidy power distribution wiring. Simply solder you power leads directly to the contact points on this board. The PCB contact points are gold plated for optimal efficiency.
Best Deals from Power Boards