Cooper Bussmann NH Fuse Base
Gupta Radio Service & Electronic is a prominent Supplier of Gupta Radio Service & Electronic. Maximise Workplace Safety & Flexibility, Minimise Risk. The New Cooper Bussmann® NH Fuse for Sizes 00000 A Convenient & Flexible approach to Increased Safety, with Unique Modular & Progressive design, enhancing Protection to installations, Circuits and Personnel. Enhanced Electrical Installation Safety Thermoplastic base Resistant to hight temperature and self-extinguishable, UL94V0 compliant. Phase barrier, Terminal shield and Top cover facilitates IP-20 finger safe protection Large Clearances Unique Modular & Progressive design Available in single pole, with easy to assemble multiple pole option Optional, Progressive choice of Accessories, as per users need Phase barrier Terminal shield Top Cover Flexible Mounting Options Fixation system to 35mm DIN rail for fast and easy installation Screw mounting option also in the same base Convenient Fast fixing and release on DIN Rail On site Multiple Pole Assembly as well as Accessories fitting No Tools Required for joining poles or fixing Accessories Operated fuse Indication viewable even with top cover in place Versatile & Rugged Rated for 690V, hence suitable for wider range of applications Silver plated contacts with high-contact pressure springs Suitable for Aluminum Terminations
...moreCooper Bussmann NH DIN Industrial Fuse
Owing to our commitment towards quality, we have established ourselves as a trusted Supplier of Cooper Bussmann NH DIN Industrial Fuse.Designed to Save Time & Money, Engineered for Safety & EnvironmentDual Indication Saves Time & Money By quicker Identification, Insulated Grip Enhances the SafetyCooper Bussmann gives yet another reliable and safe fuse range to protect circuits and Installations with ease – 500V, NH DIN style, LV Fuse range with Double Indication System and Optional Insulated Grips. Quick & Easy Identification : Bussmann's NH dual indicator fuse, India's first, is designed with additional center indicator in front for easy and quick identification of operated fuse links, overcoming the problem with conventional Single(only Top) indicator types due to mounting height, shrouds, termination,panel darkness, etc. One of the indicator is always visible in all situations of mounting with easy and convenient visual identification and another can be used for remote alarm annunciation. Insulated Metal Gripping Lugs (IMGL) : Dual Indicator range also comes with optional Insulated Metal Gripping Lugs types, saving the precious installation space and increasing Clearances thus enhancing the Operators and Installation Safety. Specially suitable for adverse Industrial environmental applications of Steel, Cement, Chemical, Oil & Gas, etc. Unmatched Material & Manufacturing Technology : Fuse links are totally free from Environmentally dangerous Lead & Cadmium and WEEE & RoHS complaint. Applications Suitability : 500 Volts - Better suited than ordinary 415V fuses for applications like Capacitor; Mines, DG Sets, Petrochemical Plants, Power Electronics System, etc where circuits can attain higher voltages than 415V. High Breaking Capacity, 120kA - Suitable for use near the source, even in big interconnected network systems, including multi source networks. Current Limiting Performance - Low Cut Off and Let Thru Values, can replace existing fuses without affecting the Type 2 Co-ordination. Globally Accepted : Manufacturing electrical equipment for exports? The Cooper Bussmann NH fuse line is acceptable throughout the globe. The range conforms to IEC lS(BlS) VDE and carry stringent globally accepted markings - VDE CCC CE. Accessories : Full range of Accessories - Fuse base, Fuse Rail, Fuse Pulling Handle, isolating links, etc available.
...moreCooper Bussmann Medium Voltage Fuse
We are counted among dependable Suppliers of Cooper Bussmann Medium Voltage Fuse. Description : A range of Medium Voltage Fuses, dimensions as per BS2692, Complete with pyrotechnic striker, if provided, suitable for general protection purpose. Higher current rating cab be obtained by using fuse links in parallel. Suitable for Indoor & Outdoor use.Ratings Volts : 3.6 kV – 12 kV AMPS : 5 – 125 Amps Breaking Capacity : 20 kA – 40kA StandardsApprovals : Comply with BS 2692-1 Dimensional Standard
...moreCooper Bussmann Low Voltage Fuse Holder
We bring forth the best Cooper Bussmann Low Voltage Fuse Holder. We are a trusted Supplier of Cooper Bussmann Low Voltage Fuse Holder. Description : Fuse holders for BS type LV industrial fuse links, clip on and bolted type for wide variety of applications.Ratings : Volts : 660 V 550 V ac Amps : 20 Amps - 125 Amps Breaking Capacity : 80 kA Class of operation : gL gG or aM Rated Frequency : 50Hz 60Hz Material : Industrial grade non hygroscopic, phenolic moulding and corrosion proof metal parts. Mounting Type : Screw Stud Busbar Applications : Lighting & heating equipment, motor protection,control equipment & circuit protection, StandardsApproval : Comply with IEC 60269, BS 88 and IS 13703. ISI marked (except for LALD)
...moreCooper Bussmann Low Voltage Fuse
Description : Fuse holders for BS type LV industrial fuse links, clip on and bolted type for wide variety of applications. Ratings : Volts : 660 V 550 V ac Amps : 20 Amps - 125 Amps Breaking Capacity : 80 kA Class of operation : gL gG or aM Rated Frequency : 50Hz 60Hz Material : Industrial grade non hygroscopic, phenolic moulding and corrosion proof metal parts. Mounting Type : Screw Stud Busbar Applications : Lighting & heating equipment, motor protection,control equipment & circuit protection, StandardsApproval : Comply with IEC 60269, BS 88 and IS 13703. ISI marked (except for LALD).
...moreCooper Bussmann HRC Fuse Holder
We are a well known Supplier of Cooper Bussmann HRC Fuse Holder.t’s Easy to Change. It's Safe, saves Time & Watt LossThe Cooper Bussmann® SAFElocRange BS Type HRC Fuse HoldersFeature rich Fuseholder Reduces Downtime by facilitating Quick Fuse replacement, Increases Safety & Convenience and reduces Power LossNNS ENS SAFEloc is simple, safe & convenient fuse holder to accommodate compact range of Offset Blade Tag type HRC fuse links, type NSD ESD , size F1 F2, as per BS88 part 6 and IEC 60629 - 2 - 1, Section IVThe direct connection between fuse blades and plated base contacts results in lower Power Loss with increased reliability.Available in two colours - Black (Standard) and White; Cooper Bussmann® SAFELoc Fuse Holders are offered with the following features : Easy Fuse Removal : Fuse holders front cover employ a unique slide snap carrier action for positive and secure insertion and removal of the fuse link. This provides positive, stress free fitting of fuse links and locks the fuse link in position ensuring safe insertion and withdrawal from the base. Quick Fitting : Fuse base incorporates a 35 MM DIN rail mounting facility besides a single screw fixing, giving quick & easy fitting cf the base in enclosures. Savings : Fast insertion removal of fuse link with the carrier in cover and quick fitting in panels saves lot of time, leading to significant savings in downtime & associated costs. Fire Retardant : Fuse base are made of high impact resistant, heat resistant glass filled, thermoplastic polyester which do not easily support fire. Safety : Fully insulated cover and cable terminals with sliding retained shroud give complete personnel protection against direct contact or electric shock. Low Watt Loss : The direct contact between fuse link blades and the plated base contacts provides lower watts loss and increased reliability. Motor Protection : The compact range of fuse links ie NSD and fitted into the SAFE loc holders, have excellent ability to protect induction motor circuits. Application : Provides safe and easy method of protecting a wide range of electrical equipment such as lighting, heating, and control equipment circuits.
...moreCooper Bussmann High Voltage Fuse
All Bussmann British style fuses are tested to IEC 60269 Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In the North America fuses are required to clear only their rated voltage. LCT, LET, LMT & LMMT Voltage Rating : 240Vac150Vdc Current Rating : 6 - 900 Amps Interrupting Rating : 200kA RMS Symmetrical Agency Information Designed & Tested to BS88: Part 4, IEC 60269 Pant 4 UL Recognized, Std. 248-13, C € Watt loss provided at rated current
...moreelectronics engineers
electronics processing services
Be first to Rate
Rate This