Crescent Combustion Systems Ghodbunder Road, Thane, Maharashtra

  • Self Recuperative Radiant Tube Burner

    Self Recuperative Radiant Tube Burner

    Request for Price

    Features 15 to 250 kw turndown range 10:1 fuel: natural gaspropanelpg preheated air upto 700ºc electrodes can be easily replaced flame tube:silicon carbide applications heat treatment furnace tunnel furnace reheating furnace strip line ceramic furnace.

    ...more
    Get Best Price
  • Ribbon Burner

    Ribbon Burner

    Request for Price

    Features 2.3 to 5.8 kw100mm ribbon length turndown range 3:1 mixture pressure: 0.5-1.6 mbar fuel:natural gaslpgpropane electrodes can be easily replaced three flames burner on request applications baking oven for foodstuff air heating in oven vial sterilizing machine industrial packing machine braze welding machine.

    ...more
    Get Best Price
  • Radiant Tube Burner

    Radiant Tube Burner

    Request for Price

    Features 30 to 300 kw turndown range 10:1 fuel: natural gaspropanelpgproducer gas air & gas pressure at the burner 45 mbar electrodes can be easily replaced. operation with preheated air upto 450ºc separated gas and air inlet, no flashback applications heat treatment furnace continuous galvanizing annealing furnace normalizing and hardening furnace nitriding furnace carbonitriding furnace carburizing furnace

    ...more
    Get Best Price
  • Premix Tunnel Burner

    Premix Tunnel Burner

    Request for Price

    Features 1 to 525 kW Can burn any standard fuel gas at mixture pressures ranging from 2.54 mm WC to 1524 mm WC, easily lighted at stated mixture pressures. Long annular orifice reduces back firing even at lower mixture pressures. Shorter flame length & higher heat release (On Standard Blocks) Pilot tip edge is screwed in the body to ensure permanent and correct location of pilot flame. Integral flanged units are available for pressurized furnaces. Applications Wire Annealing furnace Wire Patenting furnace Copper Launder Heating Heat Treatment furnace

    ...more
    Get Best Price
  • Pilot Burner

    Pilot Burner

    Request for Price

    Features 5 to 15 kW Mixture press : 2 to 6 mbar AirGas pressure : 30 70 mbar Fuel : Natural GasLPGPropane Size : ½”, ¾” & 1” Excellent flame stability Applications Pilot burner Aluminium Billet Reheating furnace Pouring Spout Heating

    ...more
    Get Best Price
  • Packaged Metallic Burner

    Packaged Metallic Burner

    Request for Price

    Features 100 to 435 kW Turndown range 30:1 to 50:1 Fuel : Natural GasLPGPropane High excess air Separated gas and air inlet, no flashback On ratio firing Applications Air heating Colour coating oven Foodstuff oven Textile and dyeing purpose Stenter Steam generator

    ...more
    Get Best Price
  • Nozzle Mix Metallic Burner

    Nozzle Mix Metallic Burner

    Request for Price

    Features 30 to 600 kW Turndown range 10:1 Fuel : Natural GasPropaneLPG Excellent flame stability with excess air, excess fuel and ON-ratio firing, over 400% excess air. Separated gas and air inlet, no flashback. Applications Air heater Steam generator Drier Heat treatment furnace for low temperature Homogenizing furnace Textile drying Low temperature furnace

    ...more
    Get Best Price
  • Nozzle Mix Burner

    Nozzle Mix Burner

    Request for Price

    Features 10 to 3750 kW. Turndown range 10:1 Fuel : Natural GasPropaneLPGCoke OvenBFG Producer Gas. Air & gas pressure at the burner - 44 mbar Operation with Preheated air upto 450°C Burner's refractory block operating temperature up to 1750°C Separated gas and air inlet, no flashback Applications Reheating furnace Continuous galvanisingAnnealing furnace Melting furnace Forging furnace Heat Treatment furnace High Temperature furnace Laddle Heating

    ...more
    Get Best Price
  • Midget Mixer

    Midget Mixer

    Request for Price

    Features Compact sizes (18” to 34”) Mixer body: Brass Fuel: Natural GasPropaneLPG Applications Pilot burner Low capacity premix burner

    ...more
    Get Best Price
  • High Velocity Burner

    High Velocity Burner

    Request for Price

    Features 30 to 600 kW Turndown range 10:1 Preheated Air up to 400 º C Fuel: Natural GasPropaneLPG Excess Air Over 400%. Separated gas and air inlet, no flashback. Optional: Refractory burner block available Applications Heat Treatment furnace Forging furnace Ceramic kiln Stress relieving Reheating Turndish heatin

    ...more
    Get Best Price
  • High Blast Torches

    High Blast Torches

    Request for Price

    High Blast Torches Features 12 to 850 kW Fuel : Natural GasPropaneLPGCoke Oven Air Pressure required : 1.4 bar to 8.4 bar Min. gas pressures : Coke-oven gas- 13 mbar Min. gas pressures : Natural gas-7.6 mbar Min. gas pressures : LPGPropaneButane-2.5 mbar Applications Ladle & Crucible Melting furnace Launder Heating Cupola firing Core drying Pouring Spout Heating

    ...more
    Get Best Price
  • Flat Flame Burner

    Flat Flame Burner

    Request for Price

    Features 16 to 1500 kW Turndown range 10:1 Fuel: Natural GasPropaneLPGCoke OvenBF Producer Gas Max. Air pressure at the burner 70.4 mbar Operation with Preheated air up to 450°C Burner's refractory block operating temperature up to 1750°C Low Nox Levels Applications Annealing furnace Zinc Melting Pot furnace Cone and Pit furnace Reheating furnace Aluminium Melting furnace

    ...more
    Get Best Price
  • Excess Air Nozzle Mix Burner

    Excess Air Nozzle Mix Burner

    Request for Price

    Excess Air Nozzle Mix Burner Features 16 to 1700 kW. Turndown range 10:1 Fuel : Natural Gas PropaneLPGCoke OvenBFG Air pressure at the burner - 25 mbar Gas pressure at the burner - 10 mbar Operation with Preheated air upto 450°C Burner's refractory block operating temperature upto 1750°C Separated gas and air inlet, no flashback Over 800% excess air Applications Heat treatment furnace Low Temperature furnace Annealing furnace Stress Relieving furnace Hot Air Generator Laddle Heating

    ...more
    Get Best Price
  • Dual Fuel Burner

    Dual Fuel Burner

    Request for Price

    Features Gas-90 to 1450 kW, Oil-100 to 1650 kW Gas turndown range 10:1 Oil turndown range 6:1 Air & Gas pressure at the burner 70100 mbar Fuel-Natural GasPropaneLPGLDOFOKerosene Operation with preheated air upto 450ºC Burner's refractory block operating temperature upto 1750 ºC Excellent flame stability instant lighting with either fuel Separated gas and air inlet, no flashback Applications Heat Treat furnace Annealing furnace Forging furnace Ceramic Baking furnace Drier Incinerator Melting furnace Hot Air Generator

    ...more
    Get Best Price
  • High Velocity Burner Silicon Carbide Nozzle

    High Velocity Burner Silicon Carbide Nozzle

    Request for Price

    Get Best Price
  • Gas Ratio Regulator

    Gas Ratio Regulator

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

Contact Information

Crescent Combustion Systems

  • Jay Naidu
  • No.111/112, 1st floor, Orion Business Park, Ghodbunder road, Next to Cine Wonder Mall, Thane west, Maharashtra

Find Popular Pilot Burner Dealers

top