TMR DIN Rail Timer
Relay Contract 5A, 230 VAC / 24 VDC resistive load. Repeat Accuracy : 0.5%, Setting Accuracy : 5% Size : [22.5 (w) x 75(H) x 105 (D)] mm. (Refer Fig. - 13) 35 mm. Rail Mounting or Screw Mounting Order Code : MODEL - SUPPLY EX. : TMR 23-230V.
...moreProcess Indicator
It is use to Display following parameters, corresponds to the linear current / voltage input. RPM, MPM, AMP, HZ, % RH, `C, F, KG/CM2, mBAR, BAR, KG, RATE etc.
Accuracy : +/- 0.25% of full scale or +/- 1 digit, whichever is greater,
Power Supply : 90 to 250 VDC/DC @ 50/60 Hz. (24 VAC.DC provided on request.)
...morePlastic Converter Plate
46 Per Piece
Material : Plastic
Color : Black
Shape : Rectangular
...morePhase Failure Relay
Model : PCON - PF - 5 It monitors 3 phase supply voltage, Relay remains ON under healthy voltage condition, and during phase failure or phase unbalance (50V +/-5V, Fixed) relay becomes OFF (Refer Fig. 20) Trip time delay : 2-3 Sec, Auto Resetting Mode. Supply / Monitoring voltage : 440 VAC, 50/60 Hz. Relay Output : One change over (1CO), 5A @ 230 VAC / 28 VDC resistive load. Size : [70(W) x 89(H) x 50 (D)] mm, 35 mm Din Rail or Screw mounting, (Refer Fig. 21) Order Code : PCON - PF-5
...moreLLC PROBE / ELECTRODE
For electrically conductive liquid, three sensing probes for High (H), Low (L) & Ground (G) levels, suspended type mounting, Probe material of contact / connection : SS316 Probe outer insulation : Engineering grade plastic - Delrain Probe Dimensions : 70 mm Height x 18 mm O.D., Cylinder.
...moreLiquid Level Controller
Applicable for (1) Electrically Conductive (Sensitive) liquid like water and (2) Electrically Non-Conductive liquid like diesel, oil etc. Input Sensor (1) For conductive liquid, use a three sensing electrode [High (H), Low (L), Ground (G)] of suitable electrically Conductive metal (like stainless steel) and (2) For non-Conductive liquid, use a two set (High (H) & Low (L) of float type magnetic reed switch sensor. Liquid Sensing to relay tripping time delay is less than 1 sec. Electrode Maximum Voltage : 24 VAC & Current : 1 mA (50/60 Hz) Galvanic isolation via transformer. Relay Output : One Change over (1CO), 5A @ 230VAC/28VDC resistive load. Size : [22.5(W) x 75(H) x 105(D)] mm. (Refer Fig. 13) 35 mm. Rail Mounting or Screw Mounting. Order Code : MODEL-SUPPLY, Ex. : LLC-11-230V.
...moredigital preset timer
DIN Rail Timers
proximity control unit
Panel Mounting Timers
phase failure relays
length counter
Be first to Rate
Rate This