Automatic Street Light sensor Switch
490 - 550 Per piece
1 Piece (MOQ)
contactor relay
Get Price Quote
Two of three phase motor currents are monitored by current transformers. The internal solid state circuitry compares with preset current level.When load currents exceeds the preset trip level,red LED iIIuminates,after the preset time, the device trips, and changes internal SPDT relaycontacts.Red LED remains illuminated indicating an overload trip has occurred. Until manual or remote electrical reset by interrupting supply,is initiated.If load current falls off below setpoint before preset delay, device resets trip timer. With the aid of LED flashing at 100% ofpreset load, actual load currents can be determined without the aid of Ammeter. Test button provides the means of testing service-worthinessand integrity of the device. Internal relay iS energized in normal operation condition(fail—safe) and will not become ready mode with eithersupply lost or own failure. *Starting delay range : O.2—30 seconds.*Trip delay time range:0.2-10 seconds.*May be used as electronic shearpin by setting trip time to minimum. Specifications:1.Phase Loss Protection2.Typical Wiring3.Compact Design4. Multiple Protection Functions5.Wide Current Adjustment Range (10: 1)6.Ammeter Function7.Trip Indication LED8.High Accuracy9.Manual Instantaneous Reset10.Electrical Remote Reset11.Test Function12.Ambient Insensitive13.Low Energy Consumption14. Fail-safe Operation (No Volt Release) Wide Adjustment Range:Has wide current adjustment range of over 10.1 .Current Setting:-*a)Type 05:0.5-6A*b)Type30:3-30A*c)Type60:5-60AControl Voltage(50/60Hz)*a)220:90-260VAC*b)440:320-480VAC Output Relaya)Mode: 1-SPDT(1C)*b)Rating:3A/250VAC Resistive*c)Status: Normally EnergizedTime-Current Characteristic:Definite;Operating (Trip) Indication:-2LED
Best Deals from Circuit Breaker
Molded Case Circuit Breaker
Get Price Quote
Electric ratings: AC5060Hz, AC220V~690V DC250V~500V, 16A~1250A; Application: for power distribution or protection of the circuits from over-load, short-circuit and under-voltage. In addition, the breaker could be applied to infrequently start the motor and the over-load, short-circuit and under-voltage protection of the motor, as well. Standard: IECEN 60947-2.
Capacitor
Get Price Quote
Capacitor, Circuit Breakers, load sharing relay, synchronizing relay
Gear
Get Price Quote
Gear, Girth Gear, roller hub, Shafts, trunion head, Cement Mill, kiln
Electrical Switches
Get Price Quote
Electrical Switches, electrical sensors, Electrical Relays
Electric Switches
Get Price Quote
Electric Switches, electric switch board, Polycab Cables
Switchgears
Get Price Quote
Switchgears, Cables
Switchgear
Get Price Quote
Switchgear, Electronic Goods, Cables Laying, electrical item
Switch Gears
Get Price Quote
Switch Gears, Cables, Electrical Accessories, energy saver lamps