contactor relay
Get Price Quote
Two of three phase motor currents are monitored by current transformers. The internal solid state circuitry compares with preset current level.When load currents exceeds the preset trip level,red LED iIIuminates,after the preset time, the device trips, and changes internal SPDT relaycontacts.Red LED remains illuminated indicating an overload trip has occurred. Until manual or remote electrical reset by interrupting supply,is initiated.If load current falls off below setpoint before preset delay, device resets trip timer. With the aid of LED flashing at 100% ofpreset load, actual load currents can be determined without the aid of Ammeter. Test button provides the means of testing service-worthinessand integrity of the device. Internal relay iS energized in normal operation condition(fail—safe) and will not become ready mode with eithersupply lost or own failure. *Starting delay range : O.2—30 seconds.*Trip delay time range:0.2-10 seconds.*May be used as electronic shearpin by setting trip time to minimum. Specifications:1.Phase Loss Protection2.Typical Wiring3.Compact Design4. Multiple Protection Functions5.Wide Current Adjustment Range (10: 1)6.Ammeter Function7.Trip Indication LED8.High Accuracy9.Manual Instantaneous Reset10.Electrical Remote Reset11.Test Function12.Ambient Insensitive13.Low Energy Consumption14. Fail-safe Operation (No Volt Release) Wide Adjustment Range:Has wide current adjustment range of over 10.1 .Current Setting:-*a)Type 05:0.5-6A*b)Type30:3-30A*c)Type60:5-60AControl Voltage(50/60Hz)*a)220:90-260VAC*b)440:320-480VAC Output Relaya)Mode: 1-SPDT(1C)*b)Rating:3A/250VAC Resistive*c)Status: Normally EnergizedTime-Current Characteristic:Definite;Operating (Trip) Indication:-2LED
Automatic Street Light sensor Switch
490 - 550 Per piece
1 Piece (MOQ)
Best Deals from Electrical Circuit Breaker
Switch Gear
Get Price Quote
100 Piece (MOQ)
NM8S Series MCCB
Get Price Quote
Electric ratings: AC5060Hz, AC220V~690V DC250V~500V, 16A~1250A; Application: for power distribution or protection of the circuits from over-load, short-circuit and under-voltage. In addition, the breaker could be applied to infrequently start the motor and the over-load, short-circuit and under-voltage protection of the motor, as well. Standard: IECEN 60947-2.
Circuit Breakers
Get Price Quote
Circuit Breakers, load sharing relay, synchronizing relay, plug in relay
Switch Gear
Get Price Quote
Switch Gear, Cable, Transformer, Switchboard, Electrical Wire
Switch Gears
Get Price Quote
Switch Gears, Cables, energy saver lamps, HPMV Lamps, Lighting Fixtures