TOC ANALYZER 2000 SERIES
1,350,000 Per Set
1 Set (MOQ)
FEATURES : Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self-testing flow rate control to ensure high performance and safe operation. Low current system design also ensures operation safety. Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data, outstanding particle handling capability and capable to handle small sample volumes. Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector. Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s safety. Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data. TOC detector the 24 bits data solution extends monitoring range. Controlling system with 32bin processing greatly improves performance.  GENERAL: TOC (Total Organic Carbon), which directly shows the total organic content is regarded as a key factor to evaluate the pollution potential of organic compound in water. After 3 years research and development, successfully launch our new product: patent laws, our TOC can meet requirements for application in water analysis, environment monitoring, pharmaceutical production, quality control, processing control, etc. So far launch 2 models TOC-2000 (Catalytic combustion oxidation) (Wet chemical oxidation by UV which are widely used for quality control of drinking water, industrial water, sewage and waste water, meanwhile, it has wide application in monitoring of River, Lake, Sea and surface water.  • Model: TOC - 2000 • Detector: NDIR • Parameter: TC,TIC,TOC. • Digestion Mode: High Temperature combustion. • Operation Mode: PC control. • Application: Liquid sample, Gas sample, Solid Sample. • Gas Requirement: Oxygen /Nitrogen ≥99.995%. • Measurement Range: 50 µg/l -30,000mg/l • Detection Limit: 50 µg/l. • Repeatability: 3%. • Accuracy: 2%. • Maximum salinity: 85g/l. • Power: AC 220V,50Hz OR AC 110V,60Hz. • Size: 430×455×440mm.  CONVENIENT SOFTWARE OPERATION INTERFACE : Sample measurement processing monitoring • Set different name, concentration and sample volume. • Real-time sample reaction. • On-line AVG and RSD calculation of testing results.  Display and monitoring of sampling • Sampling volume real-time monitoring. • Automatic sample draining monitoring. • Real-time display and monitoring for heating, cooling and furnace temperature. • Auto Switch of sampling and Draining. • Acidification operation by peristaltic pumps.  Scanning Curves : • Samples Curves shows in the same coordinate system for easy reading of repeatability.  Parameter Setting Interface : • Settings for heating and cooling temperature; acidification sampling and draining time; Basic setting for Pump , valve and temperature control. • Press “TC Clean, the system will automatically start drain-add Sodium persulfate-Draining - Sampling-Draining.
Electrolyte and Blood Gas Analyzer
Get Price Quote
BG 2100 is an innovative ISE Electrolyte and Blood GasAna|yzercomplementlng our existing ISE NG.The analyzer measures K+, Na+, Cl+, Ca++, pH, PCO2 and PO2 in whole blood, serum and plasma. The analyzer has a compact design, is easy to operate, economical and is virtually maintenance free. The aspirate probe has a self-cleansing mechanism affording enhanced operator safety, low carry-over and cross-contamination . 240 *128 dots LCD Display ' Soft, Keypad -200 pL Sample Volume -Whole Blood, Serum, Plasma - 65 Samples / hour Throughput Built-in Thermal Printer Â
Best Deals from Analytical Instruments
Automated HPLC
Get Price Quote
Photo diode array detector with 512 and 1024 diodes configurations are available. Peak purity calculations, spectral library search functions, three dimensional views and contour plots
Flash Chromatography System
Get Price Quote
Expandable cartridge selection, easy to purify milligrams of final compound or tens of grams of intermediate; Fraction collector carry capacity: 504 tubes of 13×100mm (9ml). 2. Rapid purification Total purification in less than 30 min 3. High quality Flash columnChromatography Systems are a rapid form of preparative column chromatography, featured in rapid separation, is especially useful in separation and purification of large scale of complex organic intermixture, combinatorial chemistry, drug discovery and natural product research and development. System control: PLC, touch screen and controlled by Windows based software.
FlowData Medical Gas Flow Analyzer
39,000 - 49,000 Per set
1 set (MOQ)
Oxygen Concentrator Analyzer OxyData-C b
39,000 Per Unit
1 Unit (MOQ)
PH 2-wire Transmitter MODEL 873
Get Price Quote
Pantech Instrument̢۪s 2-wire Transmitters, Model 873, are designed to provide 4-20 mA DC signal on the same two wires which carry the 24 V DC power for measurement of pH. The transmitter is an ideal choice for on line pH measurement using any industry standard combined gas electrode. It provides a current output signal capable of driving load upto 650 ohms. This allows pH measurement at a distant place from the control room all the time. The temperature compensation is built in and the process temperature is measured by RTD. The compensation is provided over the complete range of 0-100 deg. C. The instrument can be calibrated throughout the range of 0-14 pH with a minimum span of 2 pH. The transmitter is available in field mounted housings with or without local digital display
Gas Chromatograph
Get Price Quote
Gas Chromatograph, electron microscope
Oxygen Gas Analyzer
19,911 Per Piece
Oxygen Analyzer
Get Price Quote
Oxygen Analyzer, Clinical Testing Services, Analytical Training Services
pH Analyzer
Get Price Quote
pH Analyzer, Conductivity Analyzer, Pressure Transmitter, process calibrator