Forced Draft Cryogenic Vaporizer
2,200,000 Per Piece
1 Piece (MOQ)
Oxygen Fine Adjustment Valve
Get Price Quote
50 Piece (MOQ)
Best Deals from Gas Plants
Dry HCL Gas Generator Plant
Get Price Quote
Commercial Hydrochloric acid in the market is available as a 30% aqueous solution and is widely used in industry in large quantities. However, for certain application, such as hydrogenation reaction and in bulk drug /pharmaceutical industry, HCl is required in the gaseous and anhydrous form. Different processes for HCl gas generation from commercial grade HCl Acid are offered based on customer requirement. These processes are as follows: Distillation or Boiling Route Concentrated Sulfuric Acid Route Calcium Chloride Route HCl Gas Generator Plants are normally available from 5Kg/Hr up to 250 Kg/Hr capacity. Large capacity plants can also be provided on request. Ablaze has a long and successful record of design and supply of several engineered systems for Dry HCl Gas Generation System. Being manufacturer of Borosilicate glass equipment, PTFE Components and PTFE lined components, Ablaze is well qualified to handle such systems, as these are the major material of construction used in such systems, Ablaze also has in-house capabilities for instrumentation and automation, which is necessary for reliable and safeoperation.
SF6 Gas Filling Machine
Get Price Quote
1 Piece (MOQ)
Psa Oxygen Plant
Get Price Quote
We are manufacturing State of Arts PSA Oxygen Plants. The Oxygen Plants work on Pressure Swing Adsorption Principle using molecular silver. Salient Features : * Capacities up to 100 NM3/HR. * No fuel is required * Purity up to 93% is easily achievable * Low Capital & running cost * Fully Automatic Applications * Colors and B & w picture tube/ glass shell Industry. * Lamp/ compact florescent lamp Industry. * Vials & ampoules. * Brazing application. * For Fish farming. * Effluent & waste water treatment. * For Chemical oxidation. * Ozone Generation. * LPG enrichment. * For lancing In steel Industries. * Effluent & waste water treatment. * For Chemical oxidation. * Ozone Generation. * LPC enrichment. * For lancing In steel Industries. * For chemical oxidation. Purity up to 93% Is easily achievable.
Head Space Oxygen Analyzer
43,500 - 45,500 Per piece
1 piece (MOQ)
The PRIMA Head Space Oxygen Meter-HSOM has a specially designed sampling configuration with an inbuilt pump and timer switch and an ultrasensitive oxygen sensor that makes it feasible to accurately measure oxygen contamination in the headspace flexible food packs or tin cans. The Model incorporates an adapted hypodermic needle to pierce the loose food packs and draw the gas using the inbuilt pump. In the case of headspace analysis of tin cans, Model HSOM when used with the tin can piercer device provides the headspace analysis of % oxygen in the tin can of heights up to 380 mm. The high vacuum pump is designed to educts the headspace atmosphere of low internal pressure. Models can work on 220 VAC mains supply or on Rechargeable Battery. This portable instrument is available with a digital readout 0-25% 02 range and 0.1 % oxygen in steps with front adjustments for zero, calibration & sampling of the headspace gas. Applications : The food packaging industry uses modified atmospheres to improve shelf life and quality of nuts, wafers, snack foods, oils, skimmed milk, milk powder and many other packaged food products within various food packages such as soft packs pouches, tin cans or bottles. Model HSOM provides an analysis method for headspace oxygen that helps quality control by determining the residual oxygen in the headspace. Model HSOM helps to adjust the speed of nitrogen gas while packaging correctly. The simplicity of operation of Model HSOM makes it ideal for quick routine measurements and repetitious laboratory studies. Technical Specifications: Display : 3 and ½ Digit LCD 12 mm high Range : 0 - 0.25% Resolution : 0.1% Accuracy : +2% at constant temperature Power : Rechargeable batteries/ 230VAC Mains Supply Sensor type : Electrochemical Sensor life : Two years of expected life Working temp. : 5-45°C Recorder Output : 0-1 V (Battery operated models) Size : 195 x 98 x 155 mm depth Weight : 1.5 kg approximately Calibration : By ambient air or certified calibration gas In-built Pump Version: Gas Eduction : By internal pump Pump Suction : Minimum 8" Hg Column Flow : 0.5 Liter/Minute Pump Timer : Adjustable between 3 to 30 Seconds (optional) Features: Internal Pump to draw a sample. Easy to operate. Adjustable timer for sample pump. Portable, lightweight Ultrasensitive Oxygen Sensor Tin can pierce press & stand available with hardened needles. Accessories: Carrying case For Inst., Charger & Accessories, Panel mounting clamps For Inst., Charger & Accessories Hypodermic syringe Three nos. Needles and one lock valve. Self-Adhesive pads 500 Nos. cut pieces of foam for flexible packs Battery charger For Rechargeable Battery operated models, only
Biogas Plant , Bio Gas Power Plant
Get Price Quote
one Set(s) (MOQ)
We are offering biogas plant , bio gas power plant etc. We provide turnkey base biogas plant , bio gas bottle filing plant,
Gas Manifold Double
4,500 Per Piece
Specification: • Gas Manifold for cylinder with M.S. Powder coated wall mounted bracket brass chrome plated block, 1 inlet and 2 outlets. Working pressure 150kg. • Working pressure 225kg.
Hydrogen Gas Generator
Get Price Quote
MANIFOLD & 3D BENDS
800 - 1,500 Per Piece
10 Piece(s) (MOQ)
Gas Manifold System
Get Price Quote
We are a well-known organization engaged in manufacturing and supplying a quality range of Gas Manifold System for Oxygen & Nitrogen. We are offering Oxygen Gas Manifold System, Nitrogen Gas Manifold System, CO2 Gas Manifold System and LPG Gas Manifold System as our range of Gas Manifold System. These Gas Manifold Systemare highly functional, and are known for their durability. We offer Gas Manifold System in safe packaging at competitive prices.
Oxygen Gas Analyzer
Get Price Quote
andy Oxygen Gas Analyzer : The Handy Oxygen Gas Analyzer are designed for accurate and reliable measurement of Oxygen in Air, Nitrogen, Argon, Hydrogen etc. Our Oxygen Gas Analyzer are based on state of art Galvanic Oxygen Sensors, and provide fast response. Our Oxygen Gas Analyzer require no periodic maintenance like replacing electrodes or electrolyte and can be calibrated using ambient air or standard calibration samples. A digital display provides direct percentage output readout. The power Source is a 9V battery. Use of C MOS integrated Circuits ensures low power consumption for long battery life. Model 101 is an Oxygen Monitor for general applications. Model 102 additionally has low Oxygen set alarm facility which is usually preset to 19.0 % intended for personal safety usage and warns if Oxygen level falls below acceptable to human system. Specifications : Range : 0.0% - 25.0% with least count 0.1%. Accuracy : + 2% full scale. Response Time : 90 % in less than 15 Sec. Display : LCD. Sensor Type : Galvanic Power Source : One 9V battery. Alarm System : Audio / Visual. Weight : 400 Gms. approx. Special Feautres : Pocket Size . Light Weight . Easy to read Display. Low Battery Indicator. Audible / Visual Alarm. Accutate Disposable Galvanic Sensor. Application :Gas Purity Check. Combuction Efficiency. Glove Boxes.Cryogenics . Microbiology Metullargy.Chemical Engineering. Plastic Manufacturing. Food and Beverages Packing. Bio-Technology. Personal Sagety. Mines. Medical Respiratory Studies. Anaesthetic Monitoring. Baby Incubators..
Parkodex Type Gas Outlet
Get Price Quote
Air Header
6,500 Per Piece
1 Piece (MOQ)
HCl Gas Generation Plant
40,000 - 7,500,000 Per Piece
1 Set (MOQ)
HCl –Hydrochloride Gas Generator-Calcium Chloride Route Hydrochloride gas is useful for Several Applications such as Hydochlorination of Bulk drug to make product water soluble, also required in the anhydrous state for critical reactions where moisture cannot be tolerated. Calcium chloride route has cheapest in working cost as there is little neutralization cost . In other routes, large amount od acids are generated whose neutralization cost is much more Dry Gas is available in Cylinders which was quite costly and found handling problems while passing gas in the reactor . Method Of Hcl Gas Generator –CaCl2 Route Several methods have been adopted by industries for HCL Gas Generator. But generation by Sulphuric Acid Route and Boiling Route are commonly practiced. We offer Calcium Chloride Route for HCL Gas Generator. Hydrochloric acid and water form a maximum boiling point azeotrope at 11O°C corresponding to a concentration of 20.24%; HCl. By adding concentrated CaCl2 solution to commercial hydrochloric acid; azeotrope point is eliminated and. the entire HCl becomes available for liberation by distillation. Anhydrous HCl gas generation through Calcium Chloride Route is the most environmental friendly technique. Process Description The above principle- is achieved in practice by feeding metered quantities of commercial HCl and CaCl2 -solution to a stripping column with a steam heated re-boiler at the bottom. The effluent from the bottom of the column is a dilute acidic calcium chloride solution which is concentrated to desired Concentration in a evaporator and re-used. The vapor leaving is condensed stage wise with cooling water and chilled brine as a coolant. The relatively dry gas passes through a mist eliminator and to the point of consumption. Salient Features Designed Considering operation and maintenance problem Proven design that is a combination of different MOC most suitable for its use Turn down ratio of 30% Simple operation makes system operation and maintenance Friendly(Less Pump and Instrumentation) ·Nearly zero Effluent system which makes pay back period fast over other systems considering Higher raw Material costs and handling and neutralization cost of Effluents Supplied by Experience team of Engineers in this field HCL Gas generation by Boiling Route This route has an advantage when 30% Hydrochloric acid is being used in a house like internally in a plant or for resin bed regeneration. As a guide line, the Azeotropic composition of HCL-water Mixture is 20.5% . One can use 20.5% Hydrochloric acid in the house and Dry HCL gas without any raw material price. The system considered for the above duty is schematically shown Process flow diagram . Commercial hydrochloric acid containing 30-32% (w/w) HCl is preheated in a preheater (H2) by steam and fed to main fractionating column (C) in which heat is supplied through reboiler (R) using steam as heating media. The vapours leaving the column are condensed through a series of condensers HE1 and HE2 with cooling water and chilled brine as coolant respectively. The gas leaving the condensers (HE1 & HE2) passes through a mist eliminator (E) & then to sulphuric acid guard (G-1, 2,3) to knock down traces of moisture. The final gas goes to the point of consumption through a flow meter (F2) The spent acid containing 20-21% HCl is cooled in cooler (H1) and discharged continuously. This plants available from 20 kg/hr to 100 kg/hr HCL Gas generation by Sulfuric Acid route This process is simple to operate and has lower Utility cost than the other commercially available processes. Required quantities of 98% sulfuric acid and 30% HCl are sparged from the tank through flow meter into Mixing Zone as to give controlled flow in the Mixing Zone. HCL gas from the solution is stripped out by the action of sulfuric acid. Required heat is supplied by dilution of 98% sulfuric acid and little steam in Evaporating Zone. HCl gas is passed through Drying Zone .In drying zone HCl Gas is enriched by drying through Sulfuric Acid. To keep more safety for dryness, HCl Gas is passed to the sulfuric acid trap. The dry product gas is measured through a rotameter and taken to a process or storage. The bottom product (spent acid) contains dilute sulfuric acid with some dissolved HCl. The bottom product is cooled in the cooling zone and taken to the spent acid storage tank. To remove Dissolved Hydrochloride gas from Spent Sulfuric Acid to minimum, Steam Connection is provided. Slight Steam is required to keep it at higher temperature and keep minimum Solubility of HCl. It is to be noted in this process that the only utility requirement for this system is cooling water and little quantity of steam These plants are available up to 60 kg/hr. If you require larger capacity ;please ask
Cylinder Filling Plants
500,000 - 5,000,000 Per no
20 nos (MOQ)
Dissolved Oxygen Analyzer
125,000 - 300,000 Per Piece
nitrogen purging system
Get Price Quote
We are offering nitrogen purging system. A portable instrument used for purging of nitrogen gas into the other equipment using suitable attachment.
Gas turbine Power'plant Kawaski
1,000,000 Per unit
Gt power plant kwaski 2011 with bop is available for sale.
CHNS+O COMBO ANALYSER
5,300,000 Per piece
1 Piece (MOQ)