solid Fuel Fired Hot Air Generator
The indirect oil fired hot air generator is of unique designed with two passes system comprising of a radiation chamber fabricated out of steel plate connected with furnace. The steel radiation chamber is designed with expansion joint to with stand thermal shock due to hot & cold condition. The outer shell is fabricated out of plate and Boiler quality tube to form passes of flue gas and for hot air generation. The entire unit is place on a common base frame. Liberally designed and fabricated H A G to ensure highest fuel efficiency and low wall temperatures. Thus ensure fuel economy and longer unit life throughout the operation. All passes of hot air generator is easily and quickly accessible for maintenance and repairs. This particulars feature reduces the break down time to a great extent and increases reliability of the unit. The furnace and other materials are properly selected and sized such that the wall temperature is much below the safe operating temperature limits. The fresh air layout is carefully and suitably designed to maintain lowest air pressure drop at rated airflow condition.
...moreSolid fuel fired
Salient Features HIGH THERMAL EFFICIENCY :you can achieve thermal efficiency to the tune of 76% TROUBLE FREE OPERATION:With its sturdy built-up high quality components and superior quality workmanship ensures trouble free operation and low maintenance cost. NO EXPLOSION HAZARDS:Due to its low stored energy and maximum safeties incorporated, there are no explosion hazards. In any conditions. �HT-AQUA� shuts off and gives an alarm. Centralized heating system. Systematic temp.control for individual equipments/tanks. Suitable for hotels, pretreated for power coating plants & electric plants.
Type : horizontal, three pass coil type.
...moreSolid fired Steam boilers
Design and manufactured as per IBR. Combine design of smoke tube & water tube results in excellent performance. Furnace design offer higher solid fuel flexibility, furnace can be operated on fluidizes bed combustion. Furnace design offers high solid fuel flexibility. Flexibility to use different fuel with FBC furnace. Higher efficiency can be achieved with FBC furnace. High steam chest volume. Good response for the fluctuating load of steam. Enough grate area to ensure complete combustion. Heat recovery unit like air preheater, water preheater option are available for high efficiency of boiler. Multi dust collector / bag filter option is also available to meet the requirement of pollution control board.
Type : horizontal 3 pass,IBR,smoke tube cum water wall membrane type
Capacity : 1 ton/hr. to 5 ton/hr. from and at 100°C.
...moreSmoke tube IBR Steam boilers
Salient Features Large Heating Surface area and furnace with high radiant heating surface maintain furnace temperature below the permission limits. Thermal efficiency is 87% ± 2 Optimum flue gas outlet temperature. Superior combustion efficiency. Fully automatic burner Hi - Tech / Imported, On-Off, High Low type. Furnace oil pre heater ( in case of heavy oil )
Type : Smoke Tube,Wet Back Packed Three Pass Boiler.
Fuel : LDO/ HSD / FO/ NG / PG
...morePressure Reducing Station
Salient Features Immediately cracks the temperature as per process requirement. Increase latent heat of steam as steam at lower pressure has higher latent heat compare to steam at high pressure. If pressure requirement is less than 3.5 kg / cm², the PRS downstream pipe line will exempted from IBR. It allows lower mechanical strength of steam using equipment & there by reducing initial cost & radiation losses. Consist of :1. Moisture separator with trap assembly. 2. Strainer.3. Upstream, downstream & by-pass valves.4. Pressure reducing valve.5. Pressure gauge with siphon on Upstream & downstream.6.Safety valve. Salient Features Immediately cracks the temperature as per process requirement. Increase latent heat of steam as steam at lower pressure has higher latent heat compare to steam at high pressure. If pressure requirement is less than 3.5 kg / cm², the PRS downstream pipe line will exempted from IBR. It allows lower mechanical strength of steam using equipment & there by reducing initial cost & radiation losses.
...moreOil/GAS fuel fired
The indirect oil fired hot air generator is of unique designed with two passes system comprising of a radiation chamber fabricated out of steel plate connected with furnace. The steel radiation chamber is designed with expansion joint to with stand thermal shock due to hot & cold condition. The outer shell is fabricated out of plate and Boiler quality tube to form passes of flue gas and for hot air generation. The entire unit is place on a common base frame. Liberally designed and fabricated H A G to ensure highest fuel efficiency and low wall temperatures. Thus ensure fuel economy and longer unit life throughout the operation. All passes of hot air generator is easily and quickly accessible for maintenance and repairs. This particulars feature reduces the break down time to a great extent and increases reliability of the unit. The furnace and other materials are properly selected and sized such that the wall temperature is much below the safe operating temperature limits. The fresh air layout is carefully and suitably designed to maintain lowest air pressure drop at rated airflow condition. Semi automatic, shell & tube type hot air generators with external furnace. Salient Features Low Maintenance due to robust design. Operating temp. Up to 250° C. Clean & contamination fresh hot air at the outlet. External furnace design with liberal grate area to ensure complete combustion & eliminate clinker formation. High furnace volume, high radiation & convection heating surface area for high thermal efficiency & long life of equipments. Optional air pre heater for increasing the efficiency. Multi dust collector/bag filter option to meet the requirement of pollution control board.
Type : horizontal three pass shell & tube type.
Capacity : 50.000 kcal/hr. to 6 lack kcal/hr.
...moreOil Fired /GAS Fired
Salient Features EXEMPTED FROM BOILER ACT : hi tech �aqua is outside the preview of boiler regulation, hence no yearly shut down, no special boiler room. HIGH THERMAL EFFICIENCY :you can achieve thermal efficiency to the tune of 85% SPACE SAVING : due to its compactness �HT - AQUA� can be accommodated even on the terrace or basement. LOW OPERATION COST:With its larger heating surface and robust pressure jet burner it achieve complete smokeless combustion, high thermal efficiency and low operating cost. Fully automatic burner consumes fuel when hot water is required. As compared to electrical hot water boiler; the operating cost is very low. NO ECOLOGICAL DISTURBANCE: Keeping in view that the hot water Boiler are installed in thickly populated area, it has been designed to give noiseless and clean operation and maintain ecological balance. TROUBLE FREE OPERATION: With its sturdy built-up high quality components and superior quality workmanship ensures trouble free operation and low maintenance cost. NO EXPLOSION HAZARDS: Due to its low stored energy and maximum safeties incorporated, there are no explosion hazards. In any conditions. �HT-AQUA� shuts off and gives an alarm. Centralized heating system. Systematic temp.control for individual equipments/tanks. Suitable for hotels, pretreatment for power coating plants & electroplating and for dryers.
Type : horizontal / vertical three pass, coil type.
Capacity : 50,000 kcal/hr to 10 lac kcal/hr.
Fuel : LDO/HSD/F.O/LPG/NATURAL GAS.
...moreMulti Cyclone Dust Collector
Multi cyclone dust collector consists of a number of small diameter cyclones, operating in parallel & having a common gas inlet & out let. MDC operate on a same principle as cyclone - creating a main downwards vortex and an ascending inner vortex.mdc are more efficient than single cyclones because they are longer and smaller in diameter. The longer length provides longer residence time while the smaller diameter creates greater centrifugal force. These two features result in better separation & dust particulates. Features: 1. High efficiency 2. Durable Mechanical dust collector is an equipment which extract dust from the boiler & retains dust particle inside the dust collector and lets clean air left to the atmosphere. The design & size are various as per the volume of dust generated & volume of air handle.
...moreElectrically operated heating equipment
Salient Features Energy input is available at doorstep; no adulteration is possible, completely pure fuel. Environment friendly, not generating NOX, SO2, CO, etc. No exhaust, no loss in exhaust, offering highest thermal efficiency. The only down time in case of electric fired system is failure of heaters, this can be sense easily and can be replaced with almost negligible time loss. In case of oil/gas fired system it will take time to know the failure and then to repair it. Annual shut down is must to maintain the efficiency. This is the only heating media which gives guarantee of uniform temp in material to be heated. This is not possible with oil/gas fuel. Though it is not utilizing natural energy like solar, wind, producer gas but it increase system efficiency drastically, so, for small electric heating system like thermic fluid heater, we call it. "Non conventional energy supply." You can derate the electric fired boiler to 10% of rated capacity without sizable efficiency loss, which is not possible with fossils fuel or solid fuel. Easily movable, only water and steam to be changed. Most suitable for RND purpose. No sequence of operation which is in case of fossil fuel like ignition, solenoid operation, flame sensing , ignition cut off etc. Only at the turn of switch the whole system will get operated. This will reduce the down time of boiler drastically. Reciprocating the system demand very easily. Most suitable for fluctuating system demand and rapid heating & cooling cycle.
...moreCoil Type Steam Boilers
coil type steam boilers Incoming water is passed through economizer to absorb the heat from outgoing gas. Preheated water is circulated through coil shaped heat exchanger. more surface area will generate in high dryness fraction to the tune of 0.9 , this will results in extra enthalpy generation almost 1,00,000 kcal hr with compare to same capacity others design boiler for 600 kghr.
...moreCoil type non IBR Steam boilers
Salient Features Exempted from Boiler Act IBR Formalities not required, certified boiler attendant is not required. Compact in size with Thermal efficiency of 87% ± 1 based on NCV. Instant steam generation within 3 to 5 minutes from cold start. Complete Packaged Boiler with all mountings & accessories with boiler. Preheated air for combustion : optional
Type : Fully automatic, 4 pass, vertical.
Capacity : 100 kg/hr to 800 kg/hr ( F & A 100° C )
Fuel : LDO/ HSD/ FO/ LPG / Natural Gas.
...moreBiomass (Solid) fuel fired
Salient Features Large Heating Surface area. Excellent dryness Fraction. Large water holding capacity with steam chest volume for effective response to fluctuating load. Amazing payback period of boiler compared to liquid / gas fired boilers. Air Pre heater, water pre heater and multi dust collector can be fitted on boilers as a optional accessories.
...moreBe first to Rate
Rate ThisOpening Hours