Sf6 Gas Filling Adaptor Nut
Get Price Quote
100 Piece (MOQ)
Cylinder Filling Pump
350,000 Per Piece
1 Piece (MOQ)
Best Deals from Industrial Oxygen gas
Oxygen Fine Adjustment Valve
Get Price Quote
50 Piece (MOQ)
FlowData Medical Gas Flow Analyzer
39,000 - 49,000 Per set
1 set (MOQ)
Head Space Oxygen Analyzer
43,500 - 45,500 Per piece
1 piece (MOQ)
The PRIMA Head Space Oxygen Meter-HSOM has a specially designed sampling configuration with an inbuilt pump and timer switch and an ultrasensitive oxygen sensor that makes it feasible to accurately measure oxygen contamination in the headspace flexible food packs or tin cans. The Model incorporates an adapted hypodermic needle to pierce the loose food packs and draw the gas using the inbuilt pump. In the case of headspace analysis of tin cans, Model HSOM when used with the tin can piercer device provides the headspace analysis of % oxygen in the tin can of heights up to 380 mm. The high vacuum pump is designed to educts the headspace atmosphere of low internal pressure. Models can work on 220 VAC mains supply or on Rechargeable Battery. This portable instrument is available with a digital readout 0-25% 02 range and 0.1 % oxygen in steps with front adjustments for zero, calibration & sampling of the headspace gas. Applications : The food packaging industry uses modified atmospheres to improve shelf life and quality of nuts, wafers, snack foods, oils, skimmed milk, milk powder and many other packaged food products within various food packages such as soft packs pouches, tin cans or bottles. Model HSOM provides an analysis method for headspace oxygen that helps quality control by determining the residual oxygen in the headspace. Model HSOM helps to adjust the speed of nitrogen gas while packaging correctly. The simplicity of operation of Model HSOM makes it ideal for quick routine measurements and repetitious laboratory studies. Technical Specifications: Display : 3 and ½ Digit LCD 12 mm high Range : 0 - 0.25% Resolution : 0.1% Accuracy : +2% at constant temperature Power : Rechargeable batteries/ 230VAC Mains Supply Sensor type : Electrochemical Sensor life : Two years of expected life Working temp. : 5-45°C Recorder Output : 0-1 V (Battery operated models) Size : 195 x 98 x 155 mm depth Weight : 1.5 kg approximately Calibration : By ambient air or certified calibration gas In-built Pump Version: Gas Eduction : By internal pump Pump Suction : Minimum 8" Hg Column Flow : 0.5 Liter/Minute Pump Timer : Adjustable between 3 to 30 Seconds (optional) Features: Internal Pump to draw a sample. Easy to operate. Adjustable timer for sample pump. Portable, lightweight Ultrasensitive Oxygen Sensor Tin can pierce press & stand available with hardened needles. Accessories: Carrying case For Inst., Charger & Accessories, Panel mounting clamps For Inst., Charger & Accessories Hypodermic syringe Three nos. Needles and one lock valve. Self-Adhesive pads 500 Nos. cut pieces of foam for flexible packs Battery charger For Rechargeable Battery operated models, only
HCl Gas Generation Plant
40,000 - 7,500,000 Per Piece
1 Set (MOQ)
HCl –Hydrochloride Gas Generator-Calcium Chloride Route Hydrochloride gas is useful for Several Applications such as Hydochlorination of Bulk drug to make product water soluble, also required in the anhydrous state for critical reactions where moisture cannot be tolerated. Calcium chloride route has cheapest in working cost as there is little neutralization cost . In other routes, large amount od acids are generated whose neutralization cost is much more Dry Gas is available in Cylinders which was quite costly and found handling problems while passing gas in the reactor . Method Of Hcl Gas Generator –CaCl2 Route Several methods have been adopted by industries for HCL Gas Generator. But generation by Sulphuric Acid Route and Boiling Route are commonly practiced. We offer Calcium Chloride Route for HCL Gas Generator. Hydrochloric acid and water form a maximum boiling point azeotrope at 11O°C corresponding to a concentration of 20.24%; HCl. By adding concentrated CaCl2 solution to commercial hydrochloric acid; azeotrope point is eliminated and. the entire HCl becomes available for liberation by distillation. Anhydrous HCl gas generation through Calcium Chloride Route is the most environmental friendly technique. Process Description The above principle- is achieved in practice by feeding metered quantities of commercial HCl and CaCl2 -solution to a stripping column with a steam heated re-boiler at the bottom. The effluent from the bottom of the column is a dilute acidic calcium chloride solution which is concentrated to desired Concentration in a evaporator and re-used. The vapor leaving is condensed stage wise with cooling water and chilled brine as a coolant. The relatively dry gas passes through a mist eliminator and to the point of consumption. Salient Features Designed Considering operation and maintenance problem Proven design that is a combination of different MOC most suitable for its use Turn down ratio of 30% Simple operation makes system operation and maintenance Friendly(Less Pump and Instrumentation) ·Nearly zero Effluent system which makes pay back period fast over other systems considering Higher raw Material costs and handling and neutralization cost of Effluents Supplied by Experience team of Engineers in this field HCL Gas generation by Boiling Route This route has an advantage when 30% Hydrochloric acid is being used in a house like internally in a plant or for resin bed regeneration. As a guide line, the Azeotropic composition of HCL-water Mixture is 20.5% . One can use 20.5% Hydrochloric acid in the house and Dry HCL gas without any raw material price. The system considered for the above duty is schematically shown Process flow diagram . Commercial hydrochloric acid containing 30-32% (w/w) HCl is preheated in a preheater (H2) by steam and fed to main fractionating column (C) in which heat is supplied through reboiler (R) using steam as heating media. The vapours leaving the column are condensed through a series of condensers HE1 and HE2 with cooling water and chilled brine as coolant respectively. The gas leaving the condensers (HE1 & HE2) passes through a mist eliminator (E) & then to sulphuric acid guard (G-1, 2,3) to knock down traces of moisture. The final gas goes to the point of consumption through a flow meter (F2) The spent acid containing 20-21% HCl is cooled in cooler (H1) and discharged continuously. This plants available from 20 kg/hr to 100 kg/hr HCL Gas generation by Sulfuric Acid route This process is simple to operate and has lower Utility cost than the other commercially available processes. Required quantities of 98% sulfuric acid and 30% HCl are sparged from the tank through flow meter into Mixing Zone as to give controlled flow in the Mixing Zone. HCL gas from the solution is stripped out by the action of sulfuric acid. Required heat is supplied by dilution of 98% sulfuric acid and little steam in Evaporating Zone. HCl gas is passed through Drying Zone .In drying zone HCl Gas is enriched by drying through Sulfuric Acid. To keep more safety for dryness, HCl Gas is passed to the sulfuric acid trap. The dry product gas is measured through a rotameter and taken to a process or storage. The bottom product (spent acid) contains dilute sulfuric acid with some dissolved HCl. The bottom product is cooled in the cooling zone and taken to the spent acid storage tank. To remove Dissolved Hydrochloride gas from Spent Sulfuric Acid to minimum, Steam Connection is provided. Slight Steam is required to keep it at higher temperature and keep minimum Solubility of HCl. It is to be noted in this process that the only utility requirement for this system is cooling water and little quantity of steam These plants are available up to 60 kg/hr. If you require larger capacity ;please ask
Cylinder Filling Plants
500,000 - 5,000,000 Per no
20 nos (MOQ)
Air Header
4,000 - 7,000 Per Piece
1 Piece (MOQ)
MANIFOLD & 3D BENDS
800 - 1,500 Per Piece
10 Piece(s) (MOQ)
Oxygen Gas Analyzer
Get Price Quote
The company has emerged as a highly reliable Manufacturer, Exporter & Supplier of Oxygen Gas Analyzer. The company offers the best quality Oxygen Gas Analyzers and Percentage / PPM Gas Analyzers that are bench top versions with long-lasting sensors. The efficient performance of the Digital Oxygen Gas Analyzers has been widely appreciated across the industrial sector in the world.Features Bench top version with high life sensor Mains 220 V A.C Operated with optional inbuilt Ni Cd which is rechargeable Batteries for standby/portable application Specifications Principle : Galvanic Cell Display : Digital Ranges : 0–199.9PPM,Resolution:0.1ppm 0 -1999 PPM Resolution : 1 PPM 0 - 30.0% for Air Calibration Alarm : 0-100 Or 0-1000 PPM as per Range Setting, with front panel setting and Direct reading dial Alarm Output : Visual on panel and 1P2W Relay contact on back panel Recorder O/P : 0-1 V DC Std., 4-20 optional Flow Regulation, Flow Meter and By Pass /Online Valve provided in an integrated configuration Gas Connections : 1/8” Swagelok Type
Gas Manifold Single
3,000 Per Piece
Specification: • Gas Manifold for cylinder with M.S. Powder coated wall mounted bracket brass chrome plated block, 1 inlet and 2 outlets. Working pressure 150kg. • Working pressure 225kg.
Air Manifold
Get Price Quote
Parkodex Type Gas Outlet
Get Price Quote
Oxygen Concentrator Analyzer OxyData-C b
39,000 Per Unit
1 Unit (MOQ)
Oxygen Flow Meter
1,800 Per Piece
Air Header
6,500 Per Piece
1 Piece (MOQ)
PSA Oxygen Gas Plant
1,000,000 - 8,000,000 Per Number
1 Set (MOQ)
Product Details: Flow Rate(LPM) 834 LPM Oxygen Generator Capacity (Nm3/hr) 50 Nm3/Hr Technology Used PSA(Pressure Swing Adsorption) Purity Of Oxygen 93+-3% No. of Cylinders Filled In A Day 200 Cylinder in a Day Application Medical Automation Grade Fully-Automatic Design Customized Country Origin Made In India
Gas Manifold System
Get Price Quote
We are a well-known organization engaged in manufacturing and supplying a quality range of Gas Manifold System for Oxygen & Nitrogen. We are offering Oxygen Gas Manifold System, Nitrogen Gas Manifold System, CO2 Gas Manifold System and LPG Gas Manifold System as our range of Gas Manifold System. These Gas Manifold Systemare highly functional, and are known for their durability. We offer Gas Manifold System in safe packaging at competitive prices.
Oxygen Gas Analyzer
Get Price Quote
andy Oxygen Gas Analyzer : The Handy Oxygen Gas Analyzer are designed for accurate and reliable measurement of Oxygen in Air, Nitrogen, Argon, Hydrogen etc. Our Oxygen Gas Analyzer are based on state of art Galvanic Oxygen Sensors, and provide fast response. Our Oxygen Gas Analyzer require no periodic maintenance like replacing electrodes or electrolyte and can be calibrated using ambient air or standard calibration samples. A digital display provides direct percentage output readout. The power Source is a 9V battery. Use of C MOS integrated Circuits ensures low power consumption for long battery life. Model 101 is an Oxygen Monitor for general applications. Model 102 additionally has low Oxygen set alarm facility which is usually preset to 19.0 % intended for personal safety usage and warns if Oxygen level falls below acceptable to human system. Specifications : Range : 0.0% - 25.0% with least count 0.1%. Accuracy : + 2% full scale. Response Time : 90 % in less than 15 Sec. Display : LCD. Sensor Type : Galvanic Power Source : One 9V battery. Alarm System : Audio / Visual. Weight : 400 Gms. approx. Special Feautres : Pocket Size . Light Weight . Easy to read Display. Low Battery Indicator. Audible / Visual Alarm. Accutate Disposable Galvanic Sensor. Application :Gas Purity Check. Combuction Efficiency. Glove Boxes.Cryogenics . Microbiology Metullargy.Chemical Engineering. Plastic Manufacturing. Food and Beverages Packing. Bio-Technology. Personal Sagety. Mines. Medical Respiratory Studies. Anaesthetic Monitoring. Baby Incubators..
Dissolved Oxygen Analyzer
125,000 - 300,000 Per Piece