Vortex Mixer / Cyclo Mixer
The intended use of this mixer is to mix chemical or reagents by vortex motion with samples in tubes, flask or beaker.
...moreVortex Mixer
Mains Input : 230V/50Hz |110V/60Hz A.C. Supply W x D x H : 160(W) x 190(D) x 115(H) Body : Metal Body Weight : 3.0 Kg. Net Speed : 0 - 2500 RPM ( Variable ) Operation modes : Touch Or Continuous
...moreSmall Foot Print Brushless Centrifuge
Rotor : Swing out type [Horizontal] Capacity : As Per Selected Rotor Main input : 220v, 50Hz, / 110v, 60Hz Speed : Variable Up To 4000 RPM Timer : Digital Timer (1 to 30 minutes) Size : (W) 325 x (D) 293 x (H) 230 mm Weight : 8Kg. Net Motor : BRUSHLESS MOTOR R.C.F : As Per Selected Rotor Top Cover : Transparent Poly Carbonate
...moreSmall Centrifuge
Model with Timer Features and without Timer are available please refer Rotors Range Table for selecting option.
...moreRotary Mixer
This is an accessory for ESR Analyzer . It is preparing the perfect samples before the test .It will save the man hours and improve the results by better samples. To mix or get dissolved pre coated chemicals or reagents with sample blood in Up to 12.7mm diameter tubes.
Brand Name : Labline
Warranty : 1 Year
...moreRocking Platform
This is an accessory for Western Blot Test . It can hold 2 trays and the reagent will flow from one end to another due to rocking motion . It is Dual purpose device. 1] Carry out chemical process on sample strip for western blot test. 2] To mix regents with sample blood in tubes below 15ml capacity.
...moreneedle destroyer
Mains Input : 230v, 50Hz / 110v, 60Hz , AC Body : Metal Body Gauge Of Needles : Can Burn 30 to 20 Gauge Destruction Time : 1.5 to 3 Seconds Burning Temp. : 1400° C to 1800° C Weight : 2.1 Kg. Net Overall Size : 155 (L) x 129 (W) x 86 (H) mm
...moreNeedle and Syringe Destroyer
This device is designed to destroy the used needles by induction burning and cutoff the used syringe stem by high quality hardened stainless steel blades. The intended use of device is to destroy used needle below 20 sgw by burning and to cutoff the stem of syringe to avoid reuse or needle prick injuries.
...moreMEDIUM CENTRIFUGe
Model with Timer Features and without Timer are available please refer Rotors Range Table for selecting option.
...moreHematocrit Digital Centrifuge
Capacity : As per Selected Rotor Main input : 220v , 50Hz / 110v , 60Hz Max. Speed : As per Selected Rotor Timer : Digital Timer(Upto 0 to 60 minutes) Size : (W) 355 x (D) 410 x (H) 280 mm Weight : 14 Kg. Net Motor : Universal (AC/DC Carbon Brush Type) RPM Indicator : Digital Up to 5 Digits : LCD Display Speed Regulator : Step less Electronic
...moreHematocrit Centrifuge
Labline is one of India 's most technologically advanced companies in field of manufacturing of Needle hematocrit centrifuge, Our people work together seamlessly to deliver benefits for our customer.
...moreDry Bath Incubator
This is an accessory for the bio chemistry analyzer .The intended use of this device is To warm up the sample blood tubes up to 70�c from ambient temperature. The default setting is 37� C , but it can be programmed up to 70� C if required. It programmable digital electronics device.
...moreDigital Centrifuge
Digital centrifuge designed for safe operation in clinical laboratory. Centrifuge is designed with electronic safety lid lock .Lid latch shall not open once centrifuge in motion. Lid can only be open when centrifuge is come to complete stop. The centrifuge will not start if top lid is open. The user can preset required TIME, by programming of device. It will display Actual RPM and remaining time. Centrifuge designed with front panel display showing status at all time. This Centrifuge is intended to use in clinical laboratory for separation of serum from blood sample and sediment from urine sample.
Brand Name : Labline
...moreDifferential Blood Cell Counter
This device is designed to keep data of white cell counted during observation of blood sample under microscope . It is a device similar to calculator. The intended use of device is To enter and keep track of different white cells observed under microscope.
...moreClinical Centrifuge
These are basic electrical centrifuges. The motor is Universal type ( AC/DC carbon brush type) . The device is having Digital Electronics speed regulator . This Centrifuge is intended to use in clinical laboratory for separation of serum from blood sample and sediment from urine sample.
Brand Name : Labline
Warranty : 1 Year
Certification : ISO 9001:2008 and ISO13485:2003 , “CE” Mark Products
...moreCentrifuge Swing 60
Swing 60 all models are brushless centrifuge designed for safe operation in clinical laboratory. Centrifuge is designed with electronic safety lock. Lid latch shall not open once centrifuge in motion. Lid can be open when centrifuge is come to complete stop or very slow. But advice to open the lid when rotor is completely stop. lid open light will glow green. centrifuge comes with 06 bucket holding tubes. Six tubes can be used for larger 10 ml [17 dia * 100 mm] sample tube, the same bucket tubes can use by inserting small rubber stoppers provided for smaller 5 ml [12 dia * 75 mm] size tubes. Centrifuge designed with front panel display showing status at all time and number of cycles. this centrifuge is intended to use in clinical laboratory for separation of serum from blood sample and sediment from urine sample.
...moreBrushless Digital Centrifuge
This machine is brushless centrifuge designed for safe operation in clinical laboratory. Centrifuge is designed with electronic safety lid lock .lid latch shall not open once centrifuge in motion. Lid can only be open when centrifuge is come to complete stop. The centrifuge will not start if top lid is open. It has ac brushless motor and ac drive with protection features. The user can preset required rpm and time, by programming of device. It will also display actual rpm and remaining time. Centrifuge designed with front panel display showing status at all time. this centrifuge is intended to use in clinical laboratory for separation of serum from blood sample and sediment from urine sample.
...moreBlood Mixer
This is an equipment to make blood homogeneous. It is shake-less and gentle mixing process. It is essential pre-process for perfect result of RBC, WBC and platelets counting on Hematology Analyzer. To mix or make blood sample homogeneous in tubes below 15 ml capacity.
Brand Name : Labline
Certification : ISO 9001:2008 and ISO13485:2003 , “CE” Mark Products
Condition : New
Warranty : 1 Year
...moreAdvance Digital Centrifuge
Digital advance series centrifuge designed for safe operation in clinical laboratory. Centrifuge is designed with electronic safety lid lock .lid latch shall not open once centrifuge in motion. Lid can only be open when centrifuge is come to complete stop. The centrifuge will not start if top lid is open. the user can preset required rpm and time, by programming of device. It will also display actual rpm and remaining time. Centrifuge designed with front panel display showing status at all time. this centrifuge is intended to use in clinical laboratory for separation of serum from blood sample and sediment from urine sample.