Toxic Gas Analyser
50,000 - 200,000 Per Piece
Introduction: GAS ANALYSERS TGA-1 accurately measures the concentration of a Oxygen gas in parts per million (ppm)/parts per billion (ppb)/%. These gas analyzers use electrochemical/NDIR/ PID/Pallister sensors which have an enviable reputation for reliability, stability, and rugged design having an output linearly proportional to the concentration level of the gas.Application:Gas Analysers TGA-1 find application in - Process Control, Quality Control, Area Surveillance Safety in work areas of Factories and Research institutionsFeatures: One alarm audible & visual. User can Set Alarm with a setpoint view. Alarm relay SPDT with NO, C, and NC for online models. 4-20 mA & RS485 MODBUS for On-line models. Power 180~230 VAC OR Rechargeable battery option available (to be specified in the order). Portable models are offered with the INBUILT PUMP & FLOW INDICATOR option to draw sample gas. Easy accessible Key Function: Escape, Enter, Up, Down. OPTIONS for PORTABLE instruments only Internal pump with suction of 4”Hg Column and flow of 2 LPM Rechargeable 12 V battery with charger & Low Battery Alarm. Accessories: Carrying Case, battery charger, 1-meter tube. OPTIONS for ON LINE instruments only Panel Mount Enclosure. Accessories: Carrying Case, Panel Mounting clamps, 1-meter tube. OPTIONS for Sensor mounting Either internal with an internal pump OR surface mounting as diffusion on the instrument. Externally on the end of a cable in diffusion mode only Technical Specifications:Display : Display 16 x 2 LCD with Back LightWorking temp : 0-50°CAccuracy : + 1% FS at constant temperatureSize & Weight : 225 x 200 x 120 mm deep & 1.5 KgTechnology : Electrochemical/NDIR/PID/PallisterData : USB Output (Optional)Downloading : 4-20 mA Recorder OutputRecorder O/P : RS485 MODBUS RTUDrift : ± 1% FS as per 6 monthsEnclosure : Table Top ABSData Storage : In-built 100 readings (in auto sample mode)Power Supply : 230 V AC, 50Hz, Single phase, 5 Amps, Stabilized. Optional: rechargeable battery Alarm : Visual & audible, settable thro’ range. Low battery alarm also with Relay (SPDT) OutputFlow Indicator : 0 – 2 LPM provided.Response Time : 3 to 15 Sec < T90 at 20~80%RH
...morePSGM-1-D-AGS Continuous Stack Gas Emission Monitoring System
The PSGM-1-D-AGS –Flue Gas version range of analyzers use multiple sensor technology to measure the levels of Sulphur Dioxide (SO2), Nitrogen Oxides (NO), Nitrogen Dioxide (NO2), Carbon Monoxide (CO) and Oxygen (O2) in flue gas of Boiler / Furnace / Thermo pack Stack gas emission. SO2, NO, NO2, NOX (NO + NO2), CO, O2 The PSGM-1-D-AGS –Process Gas version range of analyzers use multiple sensor technology to measure the levels of Sulphur Dioxide (SO2), Nitrogen Oxides (NO), Nitrogen Dioxide (NO2), Carbon Monoxide (CO), Chlorine (CL2), Hydrochoric Acid gas (HCL), Hydrogen Cynide (HCN), Hydrogen Fluoride (HF), Hydrogen Sulphide (H2S), Ammonia (NH3) and other gases on request of Process / Scrubber / Incinerator Stack emission. SO2, NO, NO2, CO, CL2, HCL, HCN, HF, H2S, NH3 etc. Application : Boiler, Furnace, Thermo Pack, Process, WetScrubber, Waste Incinerator. Apply to the emission monitoring and process analysis of powerplant, cement, glass, limefactory, ceramicsfactory, sinter, coke oven, de-sulfurization, and denitration.
...morePSGM-1-D-AGS (CEMS-HW-PF) Continuous Stack Gas Emission Monitoring System
PSGM-1-D-AGS series HW-PF online monitoring gas analyzer is an on-site installation Platform mounted gas analyzer which is developed after years reaching and design on online gas analysis instruments. It can monitor gas parameters, including concentration of SO2, NOx, O2, Dust, Humidity, Temperature, Pressure, Flow and etc. It is widely applied to tail gas emission monitoring and process analysis in many fields, including coal-fired power plant, waster-to-energy plant, cement factory, glass factory, lime factory, ceramics factory, sinter, coke oven, DeSOx process and DeNOx process. PSGM-1-D-AGS series HW-PF online monitoring gas analyzer adopts 150° C. high temperature heat tracing for whole process, on-site filtering and sampling, on-site analysis and measuring technology. All paths contacting with gas are made of 316L stainless steel & PTFE. This gas analyzer has many transcendent features, such as low detection limit, accurate measuring result, easy to calibrate and compare, with simple construction and without any moving parts. Application : Boiler, Furnace, Thermo Pack, Process, WetScrubber, Waste Incinerator. Apply to the emission monitoring and process analysis of powerplant, cement, glass, limefactory, ceramicsfactory, sinter, coke oven, de-sulfurization, and de-nitration.
...morePSGM-1-D-AGS (CEMS-C) Continuous Stack Gas Emission Monitoring System
PSGM-1-D-AGS (CEMS-C) Continuous Emissions Monitoring system can monitor gases, including SO2, NOx, O2, dust, humidity, temperature, pressure, flow parameters, etc. In addition, also can monitor gases for a particular occasion such as HCI, HF, CO, CO2, NH3, H2S, Cl2, VOC, etc. PRIMA is the only high and new technology Indian company witha full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultraviolet flue gas analyzer, dust monitor, temperature pressure flow, humidity meter, HCI analyzer, HF analyzer, pretreatment system, monitoring software, etc. Technology platforms either Extractive, Hot Extractive, Hot-Wet Extraction, Dilution or In-situ measurement system with Electrochemical, PID, NDIR, TDLAS (Laser), FID, UV-DOAS measurement technology. Application : Boiler, Furnace, Thermo Pack, Process, WetScrubber, Waste Incinerator. Apply to the emission monitoring and process analysis of powerplant, cement, glass, limefactory, ceramicsfactory, sinter, coke oven, de-sulfurization, and de nitration.
...morePortable Multi-Gas Detector (PGD-Max)
50,000 - 100,000 Per piece
1 piece (MOQ)
Microcontroller-based Gas leak detector for detecting Flammable Gas Hazards, Toxic Gas Hazards and Asphyxiant (Oxygen Deficiency) Hazards. Gas Leak Protection From 4 Main Types of Hazards: 1. Flammable Gas Hazards (Risk of Fire & Explosion) o e.g. Methane, Butane, Propane, Hydrogen (LEL), etc. 45+ types available 2. Toxic Gas Hazards (Risk of Poisoning) o e.g. Carbon Monoxide, Chlorine, Phosgene, etc. 25+ types available 3. Asphyxiant (Risk of Suffocation) o e.g. Oxygen Deficiency 4. Volatile Organic Compounds (VOCs) o e.g. Formaldehyde, Benzene, etc. 25+ types available Application: Environmental monitoring in the workplace atmosphere, Levels of concentration measurement of gases for Occupational Exposure Limit of health & safety of personnel. Oxygen deficiency of breathing air in closed vessels & confined places personal safety. It signals alarms at two levels - the Short Term (STEL) and Long Term (TWA) Exposure Limits. These limits are the responsibility of different bodies, so the precise level and definition of each varies. Features: · ‘Zero’ & ‘Cal’ are software programmable for ease of operation. · Two Alarm levels, each with a flashing LED, pulsating beeps and vibration. · Alarm LED steady if silenced and off when below set-point limits. · Automatic shutdown if in absolute ‘Low battery’ condition. · Voltage power status viewable with early ‘Low Batt’ warning. · INST (Instantaneous), STEL, and TWA Readings are stored, and MIN, MAX, AVG, and PEAK values are viewable. · LED indication for Menu operation, LCD display & confidence beep. · All parameters are set using keys on the front face. · 48+ Different gases can be detected. · (Optional) Internal pump for sampling of gas from confined spaces also available · Shockproof Cover to prevent damage to unit due to accidental drop.
Detector Type : Portable
Brand Name : ESPM SENSE
Color : Green
Condition : New
Power Source : Battery
Application : Gas Detecting
Feature : Accuracy, Durable, Easy To Use, Portable, Rechargeable
Display Type : Digital
Gas Type : Combustible Gas, LPG Gas, CO2, H2, CH4 etc
Type : Portable Gas Detector
Warranty : 1Year
Country of Origin : India
Detected gas : O2, CO, CO2, O3, NH3, H2S, HCL, SO2, ETO, Cl2, NO, NO2, COCl2, HCN, N2H4, H2, ASH3, PH3, CS2, VOC
...morePortable Gas Detector-X (PGD-X)
30,000 - 50,000 Per Piece
1 Piece (MOQ)
Application: Environmental monitoring in the work place atmosphere, Levels of concentration measurement of gases for Occupational Exposure Limit of health & safety of personnel. Oxygen deficiency of breathing air in closed vessels & confined places personal safety. An instrument is usually required to signal alarms at two levels - the Short Term (STEL) and Long Term (TWA) Exposure Limits. These limits are the responsibility of different bodies, so the precise level and definition of each varies Features: ‘‘Zero’ & ‘Cal’ are software programmable for ease of operation. Two Alarm levels, each with flashing LED and pulsating beeps. Alarm LED steady if silenced and off when below set-point limits. Automatic shutdown if in absolute ‘Low battery’ condition. Voltage power status viewable with early ‘Low Batt’ warning. INST (Instantaneous), STEL, and TWA Readings are stored and MIN, MAX, AVG, and PEAK values are viewable. LED indication for Menu operation. LCD display & confidence deep. All parameters are set using keys on the front face. 18+ Different gases can be detected. Internal pump for sampling of gas from confined spaces also available Shockproof Cover to prevent damage to unit due to accidental drop
Brand Name : ESPM SENSE
Driven Type : Battery
Color : Green
Condition : New
Power : 6 V Rechargeable Battery
Automation Grade : Automatic
Application : Industrial Use
Feature : Accuracy, Digital Display, Easy To Carry, Light Weight
Weight : 0-5kg
After-Sales Service Provided : Yes
Alarm Type : Beeper
Country of Origin : India
Detected gas : CO, O2, O3, H2S, NH3, etc
Voltge : 3-6VDC
...morePersonal Air Sampler
30,000 - 40,000 Per Piece
1 Piece (MOQ)
THE PERSONAL AIR SAMPLER Model PAS25 consists of a mini pump driven by a D.C. motor working on a 6 volt rechargeable battery. These work continuously for up to 10 hours between charging. If required, the air sampler can be used, while charging by 220 V AC mains supply. The screw arrangement allows variation of flow rates between 0.5 and 2.5 litres/minute. A flow meter is mounted on the face of the box. Pulsation dampers are internally fitted on the inlet and outlet gas circuit to smoothen the air flow. The pump unit is fitted into a M.S. case of compact size. The sampler unit can be kept on a flat surface for stability at the breathing zone level of the worker to take STEL(15 mins.)/ TWA-TLV (8 hour) measurements. The air sampler is supplied with battery charger in a carrying case.
...morePE-SPMMS-C91 Continuous PM Dust Opacity Emission Monitoring System
works on in-situ methodology. continuous spm monitoring system is designed & built ontriboelectric effect. this is a phenomenon which occurs when moving solid particulate matterscomes into contact with the sensor. this phenomenon being essentially molecular, the process isvery repeatable. this method of sensing yields very accurate and highly reliable results, since thesignal generated is directly proportional to the mass flow rate. in fact triboelectric technology is theonly one available around the world which senses solid flows directly. radioactive, laser and opticalmethods are indirect as they are based on the principles of absorption of one or the other form ofenergy. the spmms-c91 range of dust monitors uses tribo-electric technology – dc sensor.this type is fundamental sensor of mass flow and can be calibrated directly in units of gm/sec orkg/hr. dc sensors have a linear response to mass flow over a wide range of gas velocities.these devices provide a simple low-cost mass flow measurement that, unlike mass concentrationmeasurement, requires no further normalization to deliver an absolute measurement ofenvironmental impact. signal generation is proportional to mass flow of solids / solid particulatematter across the sensor. mass flow, however, is an absolute standard. it provides a measurement of total mass emission froma source and used as a direct assessment of environmental impact. it is valid for any type ofprocess, combustion or non-combustion and may be considered as being the most relevantreporting method. the dc tribo-electric probes system is proportional to mass flow. the probe is linearly proportionalto mass flow and thus offers a simple low-cost solution to dust emission monitoring, by providing measurement of the environmental impact of any emission source. application : boiler, furnace, thermo pack, process, wetscrubber, waste incinerator. apply to the emission monitoring and process analysis of powerplant, cement, glass, limefactory, ceramicsfactory, sinter, coke oven, de-sulfurization, and de-nitration.
...moreoxygen meter
The prima oxygen meter model om-a is an intrinsically safe instrument which measures % oxygen in workplace atmosphere. the instrument display is driven by the electrochemical sensor output, which is of the order of 1.5 milliamps in air with voltage of 0.8 volts in open circuit. These weak output values make the sensor intrinsically safe per iec. there is no battery power required to drive the galvanometer and therefore no spark can be generated whatsoever. it has an analog display. Application : a personal safety gas monitor which is small, lightweight, versatile & as per is 5780 for safety monitoring. gases monitored: co, h2s, so2, no, no2, cl2, br2, nh3, co2, voc, o2, o3, h2, a3h3, hcn, ph3, cocl2, hcl, eto, clo2 etc.
...moreMGM-4P Personal Safety Multi Gas Monitor
PRIMA MGM-4P is a microprocessor based, handheld, convenient & portable multi gas monitor designed for the monitoring of four gases, % OXYGEN, ppm CARBONMONOXIDE, ppm HYDROGEN SULPHIDE & % LEL of a COMBUSTIBLE GAS. It is fitted with highly reliable and reputed sensors. The instrument works on disposable dry batteries, optionally a rechargeable battery can be provided. The instrument is capable of SAMPLING, VIEWING and DATALOGGING of INSTANTANEOUS VALUE, STEL AND TWA readings. Logged data can be downloaded to a computer for printing or storage along with the date and time of the readings. Two Alarms, both audible and visual are provided. Application : A personal Safety Gas Monitor which is small, lightweight, Versatile & as per IS 5780 for safety monitoring. Gases Monitored: CO, H2S, SO2, NO, NO2, Cl2, Br2, NH3, CO2, VOC, O2, O3, H2, A3H3, HCN, PH3, COCl2, HCl, ETO, ClO2 etc.
...moreHandy Air Sampler - PAS 25
35,000 - 40,000 Per piece
1 piece (MOQ)
Applications: These instrument is applicable for three things, 1) TWA-TLV/STEL, 2) Dusts, Fumes, Mists and 3) Gases, Vapours and Solvents within factories, plants, government organization, research institutions etc. 1) TWA-TLV/STEL Limits values are statutory requirements. By sampling the breathing air, the short term exposure limit can be determined. Otherwise using the sampler for an 8 hour shift the TWA - TLV value can be ascertained for the contaminant. 2) Dusts, Fumes, Mists For collection of toxic dusts e.g. arsenic, cadmium, beryllium, carbon black, cobalt, copper, lead, manganese, nickel rhodium, silver or tin, the use of a filter is the simplest. Many oxides or metal fumes, produced by casting, welding or burning, may be collected on a filter for analysis. 3) Gases, Vapours and Solvents Using the sampler, a convenient collecting method is by adsorption tubes or detector tubes suitable to the gases & vapors to be analyzed or de-adsorbtion for chromatograph analysis of the adsorbent. Also, for adsorption into a liquid contained in a bubbler for chemical analysis The PERSONAL AIR SAMPLER Model PAS25 consists of a mini pump driven by a D.C. motor working on a 6 volt DC rechargeable battery. This work continuously for up to 10 hours between charging. If required, the air sampler can be used, while charging by 220 V AC mains supply. The screw arrangement allows variation of flow rates between 0.5 and 3.0 liters/minute. A flow meter is mounted on the face of the box. Pulsation dampers are internally fitted on the inlet and outlet gas circuit to smoothen the air flow. The pump unit is fitted into a M.S. case of compact size. The sampler unit can be kept on a flat surface for stability at the breathing zone level of the worker to take STEL (15 Mins.)/TWA - TL V (8 hour) measurements. The air sampler is supplied with a battery charger in a carrying case
Brand Name : PRIMA
Material : ss
Automation Grade : Manual
Application : Air Sampling
Nominal Capacity : 0.5 to 2.5 LPM
Rated Voltage : 220V
Type : Air Samplers
Warranty : 1yr
Country of Origin : India
...moreFix Gas Detector- FGD-X
30,000 - 60,000 Per Piece
1 Piece (MOQ)
Introduction: The FGD-X is a Microcontroller-based Gas leak detector for detecting Flammable Gas Hazards, Toxic Gas Hazards and Asphyxiant (Oxygen Deficiency) Hazards. It is a Single Point Wall Mounted Instrument work on 220 VAC main supply and has a sensor fitted at the end of a cable. They use an IP 55 enclosure for the electronics as standard. Applications:They are used for continuous surveillance single point monitoring the Volatile organic Compounds in workplaces or enclosed spaces in hazardous, explosive or toxic gas conditions & environments. The parameter for measuring would be VOC with Range of 0- 100ppm and Resolution of 0.1 ppm/0.1 ppb. Features: · Two Alarms, audible and visual (separate LEDs + alerts on display), along with inhibit, acknowledge and reset options. · Alarms are settable as manual or auto reset type (Latching or non-latching) · Two potential free relay contacts for external use. · Separate Confidence flash LED to know that equipment is working properly. · 4 switch operation using Magnetic Pen (contact-less operation). · Data Outputs (Optional): Modbus RS485, 4-20 mA.
Brand Name : ESPM SENSE
Color : Green
Power Source : Electric
Application : Gas leak detector
Feature : Magnetic Pen operated (Contactless operation)
Type : Gas Detector
Warranty : 1year
Country of Origin : India
...moreOpening Hours