XYZ Piezo-stage
The XYZ PZT is an actuated linear nanopositioning stage of exceptional resolution and stability. The 2.6" x 2.6" hole in the stage center is ideal for applications involving transmitted beams, multiple probes or inverted optics. With its large distance of travel and high stability, the PZT is ideal for the most challenging microscopy and positioning applications. The PZT comes complete with position sensitive detectors for closed loop operation.
...moreWorking Electrodes
2 mm dia Gold working electrode.2 mm dia Platinum working electrode,2 mm dia Silver working electrode,3 mm dia Glassy Carbon working electrode,12.5 μm diameter Gold Microelectrode,25 μm diameter Gold Microelectrode,10 μm diameter Platinum Microelectrode 25 μm diameter Platinum Microelectrode
...moreWavelength Response/ IPCE/IQE/EQE
For measurements of relative and absolute spectral response resp. quantum efficiency of solar cells. Spectral range 300 nm 3000 nm (or as desired), cell size up to 4 x 4 cm2 . Specialised bias light adapters for tandem cells or concentrator cells available. For the determination of solar cell parameters, such as diffusion length, recombination velocity, thin film spectral transmission and others For determination of spectral mismatch factors for subsequent calibration of cells in solar simulators (simulator lamp spectrum and reference cell SR required).
...moreWater Splitting Cell
Cell with provision to put counter, reference and ITOFTO(sample).This cell has quartz window, thus light from solar simulator can be shined and experiments can be carried. Specialized cell for doing only photochemical reactions is also available.
...moreAlba VistaVision Software
VistaVision for Alba is a complete software package for instrument control, data acquisition and data processing.
...moreVCA-Optima Surface Analysis Systems
The VCA Optima series incorporates lightweight design, easy assembly, the latest Windows™ standards and user-friendly software to create a contact angle instrument that's accurate and easy to use. VCA-optima systems are suitable for research or quality control in R&D and processing engineering. Systems range from the basic Optima to the fully equipped Optima XE. Features include Dynamic capture capability, Motorized syringe, Surface energy analysis and Pendant drop analysis, to name a few
...moremanual cryogenic research station
The SemiProbe manual cryogenic research station is built on a rugged powder coated steel frame with built in vibration isolation. This system is configurable for operation at a vacuum levels of either 10 -3, 10-4 or 10-6 torr (Depending upon pump system selection) and temperatures from 85K to 425K. Our standard system utilizes 4 externally controlled manipulators, however the system is capable of mounting 6 manipulators if specified by the user. Probe tips on the manipulators are easily positioned and repositioned from outside the chamber during operation.
...moreMetrology Thin film
In the new and fast growing market for nanotechnology and its applications, Nanosurf has committed itself to smart solutions in the area of scanning probe microscopes and positioning devices with nanometre resolution, as well as being a solution provider of new nanotechnological implementations in the future. Miniaturization has been successful in most of the industrial parts and has led to lots of new, innovative solutions. The process of miniaturization has now reached the nanometre range and will therefore inspire new applications and continue to play an important role in industrial development.
...moreThe Nanosurf easyScan 2 FlexAFM
Nanosurf's renowned "ease of use" has been implemented consistently in the new FlexAFM scan head. The result is the most versatile and flexible AFM ever. Whether you want to operate the FlexAFM in air or in liquid environments, it makes no difference to you as a user. This is true flexibility!
...moreThe Cantilever Holder
A specially designed cantilever holder allows wet samples to be measured in the same manner as dry samples. Changing between the two environments is also a breeze. The choice really is yours! Just place any dry or immersed wet sample under the scan head and start measuring.
...moreTable Top Module
Xenon flashlamp, spectrally filtered to AM 1.5 Light intensity 800Wm2 - ca.1100 Wm2 No module heating duringmeasurement Module sizes up to 80 cm x 160cm, class AAA During the flash plateau, an electronic load scans the IV characteristic. Special option for high capacity modules, dark measurements or outdoor measurements Measurement period ca. 10-80 ms (adjustable for high capacity modules) Correction of data with respect to module temperature, irradiance. Target conditions STC or other desired test conditions
...moresurface area analyzer
The AcornTMArea is a revolutionary instrument designed to measure the surface area of particles or droplets dispersed in any type of liquid. This new generation (patented) technique is based on nuclear magnetic resonance (NMR) and offers many advantages in comparison with conventional first generation surface area instrumentation.
...moreSureAlign Laser Optics
The patented SureAlign™ laser optics eliminate laser adjustment once and for all, simply because the laser beam shift that normally occurs upon immersion into liquid is completely absent in the FlexAFM scan head. As a result, you are always working with an optimal laser signal.
...moresolar simulator
Photo Emission Tech., Inc manufactures and markets steady-state solar simulators that simulate natural sun light in a variety of conditions, such as those in space or at sea level. These solar simulators, also called sun simulators, provide excellent price performance. The solar simulators can be used both in laboratory or production environment. The solar simulators can be used for checking light-sensitive devices such as Solar (Photovoltaic) cell performance.
...moreSolar Simulation Systems
Photo Emission Tech., Inc., manufactures and markets solar simulation systems that meet ASTM E927 (Japanese Standard JIS C8912 and European Standard IEC 60904-9) Class A and Class B requirements. These systems can be used for checking Photovoltaic Cell Performance and in any other application where the effect of exposure to sun light needs to studied, such as photochemistry photobiology testing and environmental exposure testing. Five standard systems are available for each class. Systems can be manufactured with three different air mass (AM) filters: AM0, AM1 and AM1.5.
...moresolar module tester
Measures IV characteristics of PV modules—maximum power, open circuit voltage, short circuit current—at standard test conditions (STC, IEC standard 60904-1) Simulated sunlight spectrally filtered to AM 1,5 global, using Xenon flashlamps, intensity adjustable Suited for laboratory measurements and integration into production lines Temporal stability and spectrum at STC class A. Spatial uniformity +- 2-3% AM filtering optional
...moreWafer System
VCA-3000S 300mm stage VCA-3000S Wafer Surface Analysis Systems are specially design for use in semiconductor wafer processing quality control. The system provides quick and accurate contact anglesurface energy analysis on wafer surface to evaluate adhesion, cleanliness and coatings. The syringe mechanism can be raised for easy loading and unloading eliminating the possibility of wafer damage. Although the system was designed for wafer surface analysis it is also a useful tool for any application that requires a large stage. Samples sizes up to 12"W x 12"L x .75"H can easily be accommodated by this system
...moreSemiautomatic Probers
Semiautomatic Probers Wafer is manually loaded Software “Wizard” walks operator thru 2-point alignment Die index set Prober automatically steps die to die until completed Repeat process again
...moreelectron microscope
The CX-200 SEM is a use full for surface characterization and produces high quality images with 3.0 nm resolution at accelerating voltage, 30kv and working distance, 5mm. It’s magnification is 10X to max. 300,000 X. The CX-200 is an indispensable tool for various application areas in surface analysis. You can get the great images due to its long depth of focus. The CX-200 chose auto mode it use auto stepper motor type, micro drive, 19nm resolution. You can check point & position of a specimen. User Friendly Operation Nano stationTM is the software for CX-200 based on Microsoft Windows XP and graphic user interface. It is carried out with mouse and keyboard by menu selection. It can provide a high resolution images at a short time
Type : Automatic
Voltage : 220V
Driven Type : Electricity
Warranty : 1 Year
Eyepieces : WF10X, WF15X
Vision Angle : 5-10Degree
...morereference electrodes
AgAgCl Reference Electrode w porous Teflon Tip (AgAgCl) Reference (AgAgCl) length.80mm OD:6.0mm w Vycor frit Reference AgAgCl) w Vycor frit 4.5mm dia, 5.5cm,Non-Aqueous AgAg+ Reference Electrode w porous Teflon Tip AgAg+) (Non Aqueous AgAg+)length.80mm OD:6.0mm wvycor frit Non Aqueous AgAg+ w Vycor frit 4.5mm dia, 5.5cm,Calomel Reference Electrode (SCE)MercuryMercurous Sulfate Reference Electrode AlkalineMercurous Oxide Reference Electrode
...moreRaman Spectrophotometer
500mW laser (785nm) coupled to optical fiber to bring the light to the sample and carry it back to the cooled diode array sensors to record the raman spectrum 100-3300cm-1 with the resolution of 4 – 10cm-1 with high signal to noise ratio. Microscopic attachment available.
...moreProbe Station
Lab Assistant Family – 50 mm to 200 mm Designed for University and Commercial R&D Centers Small footprint Upgrade path Low cost
...morebeam splitter
The polarizer's transmission is maximized for the wavelength range 450 nm to 1100 nm. The extinction ratio is 10,000:1 at ±3 degrees. The polarizer is mounted into a cube on the automated filterwheel (it accommodates up to 4 optical elements) and is selected through the software.The 5050 beam splitter transmits in the range 380-750 nm. The beam splitter is mounted in a cube on the automated filterwheel (it accommodates up to 4 optical elements) and is selected through the software.
...morePlatinum Counter Electrode
Platinum counter Electrode Platinum counter Electrode (high surface area shown in coulomety cell), if you don't have this one can you provide a platinum wire of length at least 12 centimeter