Top Mounted Magnetic Level Switches
1,530 Per Piece
1 Piece(s) (MOQ)
Based in Vadodara, Gujarat we are a reputed manufacturer and supplier of Top Mounted Magnetic Level Switches. This Top Mounted Magnetic Level Switch comprises of sealed sensors, housing enclosure which is both flame proof and weather proof and a reed switch. The Switch shows the measurement by moving up and down on the probe immersed in a liquid. The Switch is constructed using materials which are equally reliable in both normal atmosphere and in water. These Switches are accurate and durable. We offer these Switches at pocket-friendly prices. Details : “Kabir”Make Top Mounted Magnetic Level Switch moves up and down on probe immersed in a liquid. The float energizes the hermetically sealed sensors, which changes from NO to NC or otherwise as the float - passes them. The reed Switch operates NO to NC which is potential free contact. Features : Height Of The Tank Or Probe Length Required No. Of Points To Be Controlled With Respect To Top Flange Material Of Construction Of Wetted Parts Top Nozzle Detail Which Is Welded On Tank On Which You Are Indenting To Mount Level Switch Housing Enclosure (Flame Proof/ Weather Proof) Specifications : Standard Range -100 mm to 4000 mm Temperature -Up to 100oC Pressure: Up to 15Kg/Cm² MOC - SS 304, SS 316, SS 316L, PP, PVDF Connection -Flange End /Screwed Or To Mention
Top Mounted Level Switch
300 Per Piece
Best Deals from Top Mounted Switches
Top Mounted Float Level Switch
Get Price Quote
The VEKSLER TOP MOUNTED FLOAT LEVEL SWITCH (TLS-19) is highly reliable and a low cost instrument. It can be used for small tanks as well as large vessels depending upon individual customer's requirement.It consists of a guide pipe made from SS 304/SS 316, a magnetic float of SS 316 that moves on the tube with rise and fall of level. Hermetically sealed reed switches are housed in the guide pipe. The switches can be fixed at any position through out the length of the pipe. But the position should be defined at the time of order as it cannot be changed at site. The factory set accuracy is +/-5mm. Since it works on magnetic principle, there is no mechanical connection and hence the chances of any wear/tear, fluid contamination are eliminated.The process connection is 3” NB Flange as per ASA 150# or any other standard as per individuals requirement. The Floats are hydro tested to work at 15 Kg/cm2. Floats for higher pressure can also be supplied. The working temperature is 90 Deg C.These are very useful for Diesel/Furnace Oil Day tanks and are supplied with IP65/EX-PROOF Gr 11A & 11B enclosures. The other applications include vending machines, small tanks, pumping stations, water tanks. Optional Relay units are available for higher current ratings.It can be wired with low load; however high resistive/inductive loads should be connected in series through control unit. This instruments is PC/PLC < DCS, Alarm Annunciator configurable. Very reliable yet a low cost instrument +/- 5mm accuracy Available in Single & Multiple Floats Hermetically sealed magnetic switches at pre fixed positions in the guide pipe Reed Switch Operation, 1, 2, 3 or 4 different positions 2" / 3" MS Flanged connection as per ASA 150# or as per customer's requirement Can be wired directly with low load, use control (Relay) unit for high resistive/inductive loads Available in Ex-Proof Gr IIA & IIB/Weather proof connection box Max. Pressure Upto 20 Kg/cm² and 80 Deg C temperature Custom designed to your exact guide length and float dimensions Side mounted bracket available for easy installation in open tanks / sumps PC/PLC/DCS, Alarm Annunciator configurable Also Available in External Cage Type Flame Proof/Weather Proof Connection Box Guided Tube : SS 304/ SS 316
Top Mounted Magnetic Level Switch
Get Price Quote
The Top Mounted Magnetic Level Switch is listed among the best available Level Switches in the market because of the special one or multi-level indication and controlling of fluid or liquid level in the tank or vessels. Equipped with an advanced Reed Switch, our Top Mounted Magnetic Level Switch has been very useful in different pumping applications. This level switch works upon the principle of magnetic flux coupling. Features : Apt for fluid having Specific Gravity Above 0.7Can operate in any Position from vertical to an inclined angle of 30oCan manage distance of 75 mm between 2 Level set Points Main Components : Vertical Guide Pipe (Stem)Reed SwitchesMagnetic Float Sliding over the Stem Construction Features : Maximum 4 Set points in a Single Level SwitchMaximum stem length will be 3 Meters. Specifications FloatS.S.316 or Teflon Coated or PP / PVDFProcess Connection Screwed OR flangedFlange Mini 1 NB to Any Size in C.S. or S.S.304 or S.S.316 or S.S. Lined C.S. EtcSwitchHermetically Sealed Magnetically Operated Reed Switch with RhodiumContact SPST / SPDT.Rating 0.5 Amp @ 240 V ACSwitch HousingDie Cast Aluminium, Weather Proof IP 65 (Enclosure) (IS 2147) OROperating Pressure10 Kg / Cm2Operating TempMaxi. 1000 C.Cable Entry½"NPT (F) OR ¾" ET (F)No of SwitchesAs Per Customer equirementStem LengthUp to 5 Meters
Top Mounted Level Switch
Get Price Quote
The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter. One of the advantages of the electromagnetic flowmeter is that it is suitable for a wide variety of applications including severely corrosive chemicals and highly abrasive slurries. The key to this versatility is that there is a large choice of materials available for the electrodes and the flowtube liner.
Top Mounted Magnetic Level Switch
Get Price Quote
Top Mounted Level Switch work on permanent Magnet Reedswitch basis. The floats which contain permanent Magnets move freely between their stops rising or falling with Liquid level movement. Hermetically Sealed within the tube are reed switches, Completed isolated from the medium. The Magnet's field actuated the reed switch as the float moves while the Stoppers restrict overrun and prevent the reed switch returning to its original position. Stopper positions should not be changed.