Slump Cone
Get Price Quote
We are offering slump cone.
Alivecor Kardiamobile 6L 1st FDA Cleared Six Lead Personal ECG Machine
8,000 Per Piece
1 Piece (MOQ)
Best Deals from Laboratory Apparatus
Tablet Friability Apparatus
Get Price Quote
1 Piece (MOQ)
Used for tablets to determine the durability from the time of production to the time of use, a transparent plastic drum rotating has plastic blade which carries the period is determined by a timber tablets are weighed before and after the test and difference in weight for a particular time period indicates the rate of abrasion.
Laboratory CVD Furnace
Get Price Quote
1 Piece (MOQ)
ApplicationCVD Furnace is designed for R&D labs, Educational institutions, Medicine and Industry, Aerospace industry, Semiconductor industry, Chemical Industries, Biomedical Industry, Pharma Industry, glass Industry, Thermal Process Technology, Advanced Materials for following Chemical analysis, Graphene, Optical Fibre, Composition, Deposition, Diffusion, Coating, Degassing, Sintering, Catalyst research, Carbon nanotechnology process etc.Features Maximum operating temperature range up to 1200°C. The CVD furnace workstation consists Split Tube/Tube furnace, a precision mass ow gas control station, a high vacuum station, and other assembling parts. The mass fow gas control station mixes multiple gases together and allows the mixed gas to ow into a fused quartz tube inside the furnace. Processing tube is included Inner diameter of the tube from 40mm to 150mm, with vacuum stainless steel anges, Vacuum compatible sample puller rod, vacuum valves, Viton O-rings, Pirani/Penning gauge and Mechanical pressure gauge. Heated Length from 100mm to 1000mm. Capable of 10 mbar vacuum in a clean empty work tube. -5 High vacuum station consists turbo molecular pump/Rotary vane pump with related vacuum fittings. Mass flow gas control station consists multiple Mass ow controllers, Gas mixing system and related pipe fittings. Compact design for minimum space requirement. Rugged and durable Construction. Outer casing is made up thick mild steel with duly powder coated or thick buffed stainless steel, gives long service life with extremely resistant. Multilayer insulation with vacuum formed ceramic bre or refractory bricks with low thermal mass. Furnace design with powerful heating elements i.e. FeCrAl and SiC in all sides of the work tube providing fast heating rate Fast heat up and cool down rates. Temperature uniformity +/- 5°C. Temperature control with PID controllers. Power control with solid state relays or Thyristor units for very precise temperature Control, wear-free and noiseless. High mechanical durability, short heating cycle and low power consumption. Optional Features Multi-zone temperature control Touchscreen temperature controller Over Temperature Limiter. Door flanges with hinges. Water cooled flanges with chiller. Digital/Analog flowmeters. Port for additional thermocouple on the flange. Process observation window on flange. Buzzer, Digital timer, Emergency shut down. Data Recorder. RS232/RS485/USB interface. Calibration of temperature measurement systems. Data Acquisition System (DAS) through software. UPS Systems. Customization as per user requirement. Caster wheels with brakes.
Softening Point Apparatus
Get Price Quote
The Softening Point Apparatus is used for determination of softening point of bituminous materials, as per IP 58 and IS: 1205. We manufacture and supply some of the best Softening Point Apparatus in this industry. We produce these units using only the best available materials to guarantee our customers 100 percent satisfaction. Components FHP electrical motor driven Stirrer Electric Heater with energy regulator Rigid stand and two steel balls with rings & ball guides.
Electric Suction Apparatus
8,000 Per Piece
1918 & 1916 Microprocessor Dissolution Test Apparatus
Get Price Quote
1 Piece (MOQ)
Microprocessor Dissolution Test Apparatus is a solid state instrument designed for the determination of active drug ingredient in any pharmaceutical formulation, tablet or capsule as per IP and USP specifications. This apparatus evaluates adequate bio-availability and provides necessary information to formulate in the development of therapeutically optimum dosage forms. The instrument is designed and manufactured for pharmaceutical industries. It is used in quality control and R & D to determine compliance with the dissolution requirement of the Tablet and Capsule as per USP/IP standards. Instrument uses the latest microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The system has user friendly prompts, which guide you throughout the measurement process. System is equipped with 4 line alphanumeric LCD display with backlit and 19 soft touch membrane type keys that provides a convenient interface for entering the data. Independent stirrer and platform keys on the front panel allow the user to easily start/stop stirrer movement or displacement of platform in the required direction at any time. The instrument has the storage facility for 200 samples. The samples being analyzed are automatically stored in the memory in different batch and sample numbers. The system has three programming modes i.e. Routine, Sustain and Control mode. It has the facility for setting up 20 different test methods using Routine and Sustain modes which are retained in the memory even when the power is switched OFF. Provision has also been made for attachment of any dot matrix printer with centronics interface so that any of the stored setups/results can be printed. The unit is provided with dissolution vessel with cover, having necessary arrangement to hold temperature sensor and the same is placed in the sturdy, acrylic water bath. The large spread out stainless steel heater ensures perfectly uniform heating. The instrument has dual channel temperature system with sensors to monitor the test temperature of dissolution vessel as well as that of the water bath. The motorized platform’s (stirrer unit) up/down movement of the instrument improves the accessibility for sampling. Stirrer speed is accurately controlled and maintained at ±1 rpm by microcontroller as per IP, USP specifications. The elapsed time for the current ongoing test is retained in the instruments memory. In case of power failure during the run mode, when the instrument is switched On again, the user has the option to run the test from the point of the power failure. Features 8 Station (Model – 1918) 6 Station (Model – 1916) Complies with USP, IP specifications Extremely Useful for Pharmaceutical Labs Highly Accurate and Easy to Operate Programmable Stirrer Speed Control i.e. (25 – 300 RPM) 20 x 4 Line Alphanumeric LCD with Backlit 19 Soft Touch Membrane Type Keys Three Programming Modes i.e. Routine, Sustain and Control 20 Independent Programmable Setups for Routine and Sustain Mode with Storage Facility 200 Samples Storage Facility Printer Attachment Facility Audio Visual Indicators for System Status Easy to Empty & Clean the Water bath with Bottom Drainage Continuation of Last Sample Run in case of Power Failure
Portable Batch Coding Machine
15,500 Per Piece
1 Piece (MOQ)
Aggregate Impact Value Apparatus
5,500 Per Piece
The apparatus of the aggregate impact value test consists of: A testing machine weighing 45 to 60 kg and having a metal base with a plane lower surface of not less than 30 cm in diameter. Level and plane concrete floor of minimum 45 cm thickness are used to support it. The base of the machine should also have provisions for fixing its base. A cylindrical steel cup of internal diameter 102 mm, depth 50 mm and minimum thickness 6.3 mm. A metal hammer or tup weighting 13.5 to 14.0 kg the lower end is cylindrical in shape, is 50 mm long, 100.0 mm in diameter, with a 2 mm chamfer at the lower edge and case hardened. The hammer is arranged in such a way that it should slide freely between vertical guides and be concentric with the cup. It is arranged that the free fall of the hammer should be within 380±5 mm. A cylindrical metal measure having an internal diameter of 75 mm and depth 50 mm for measuring aggregates. One end rounded tamping rod 10 mm in diameter and 230 mm long. A balance of capacity not less than 500 g, and readable and accurate up to 0.1 g.
Lacquer Porosity Test Apparatus
130,000 - 170,000 Per Piece
1 Piece (MOQ)
A quality control application tool widely used to test the porosity of a wax-coated metallic vessel in the labs. The container can be an aluminium tube, can or a bottle cap. To measure porosity of a tube means to conclude whether the wax coating has holes or spaces in it that possibly trap air or allow liquid through it. The apparatus uses DC potential, a copper electrode and chemical solution to test the porosity that can be read through a digital display on the device. It is an easy and accurate method to know whether the lacquer coating is continuous or has any pores in it. Raise Lab offers user-friendly and easy to operate Lacquer porosity testing apparatus that is as accurate as any other imported equipment. Revolutionize Lacquer Porosity Testing with the RLP-1 Lacquer Porosity Tester Introducing the RLP-1 Lacquer Porosity Tester, where simplicity meets precision in a single device. Designed to offer seamless usability and accurate results, this model sets a new standard in Lacquer Porosity testing, ensuring the integrity of aluminum tubes, cans, bottle caps, and foils. Discover the Features: Effortless Operation: Navigate through testing effortlessly with our user-friendly menu, streamlining operational procedures. Enhanced Visibility: The 4X20 LCD display ensures clear visibility, allowing you to monitor the testing process with ease. Microcontroller Magic: Crafted with an embedded system-designed microcontroller, the RLP-1 stands as a pinnacle of technological innovation. Instant Reporting: Experience the convenience of an in-built thermal printer, which provides real-time test reports for immediate analysis. Versatile Application: An ideal testing equipment for Lacquer Porosity testing across a range of items, including Aluminium Tubes, Cans, Bottle Caps, and Foils. Optimal Sample Size: Conduct tests efficiently with just 10 required samples, saving time and resources. Programmable Precision: Set the test duration for each sample in seconds, initiating the internal timer by simply pressing the Start key. Clear Results: View the test results on the 20X4 LCD Display, and seamlessly generate comprehensive reports with the in-built Thermal Printer. Validation Ease: Easily validate the equipment using a certified External Ammeter in accordance with ISI standard specifications and methods. Secure Your Data: Implement password protection for the real-time clock, ensuring your data remains secure. The RLP-1 Lacquer Porosity Tester epitomises precision, innovation, and simplicity, standing as a testament to our commitment to excellence. Located at C-2, Industrial Park, Moula-Ali, Hyderabad, India, this instrument redefines Lacquer Porosity testing across industries, setting new standards of quality assurance. Welcome to a world where technological prowess meets user-centric design.
Zener Diode Characteristic Apparatus
Get Price Quote
ESCR Apparatus
Get Price Quote
Longitudinal Compressometer
3,500 - 5,500 Per Piece
1 Piece(s) (MOQ)
We are a reliable Supplier of Longitudinal Compressometer. The Compressometers offered by us are sourced from reputed vendors of the market. We ensure that these reach the buyers in safe packaging options in order to avoid any damage during transit. One can obtain these at market-leading rates from us. Contact us today!
Auto Karl Fischer Titration Apparatus
Get Price Quote
1 Piece (MOQ)
Digital Melting Point Apparatus
15,999 Per unit
1 units (MOQ)
Soil Permeability Testing Apparatus
Get Price Quote
1 Piece (MOQ)
ECG 300 Electrocardiograph Machine
Get Price Quote
1 Peice (MOQ)
Product Description AC / DC Operated 3 channel ECG with data Interpretation Rechargeable Lithium Battery Battery Backup: 90 minutes (with continuous printing) Simultaneous display of 3/6/12 leads ECG waveform, and can remark the lead sign, sensitivity paper speed and filter state Memory: 150 pieces of ECG waveform and works 90 mins continuous after full battery charge Storage : 1000 cases It can store more than 1000 patient’s data (cases), more convenient for data review & statistics Portable, Light weight and sturdy look Mode of printing: Automatic/Manual Technical Specifications: 3.5″Color LCD [Touch Screen Optional] Power Supply AC: 110 ~ 240V, 50/60 Hz DC: 7.4V, 3700 mAh rechargeable lithium battery Input way : Floating and defibrillation protection Lead : 12 leads Patient leak current : ≤10μA Frequency response : 0.05Hz ~ 150Hz [-3dB ~ 0.4dB] Time Constant : Time ≥ 3.2s CMRR : ≥ 60dB, ≥ 100dB[Add filter] EMG interference filter : 35Hz[-3dB] AC Filter : 50/60 Hz Sampling rate : 1000 Hz Recording way :Thermal printing system [32 spots/mm] Specification of recording paper: 80mm [W] X20m [L] Measurement parameter: HR, P-R interval P Duration, QRS Duration, Q Interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5) + S(V1) High speed thermal paper :Paper speed: Auto Record : 25mm/s, 50mm/s Manual Record : 5, 10, 25, 50mm/s Rhythm Record : 25mm/s, 50mm/s Sensitivity choice : 5, 10, 20 mm/mV; Error: ≥15% Standard sensitivity is 10 mm/mV : 0.2 mm/mV Classification : Class I, CF applied part Enduring polarization voltage : ≥1500 mV Fuse Specification : 2pcs [5*20mm AC time lags]; T1.6AL250V [Power Supply: 220V] Machine Size : 315(L)X 215(W) X 77(H) mm Net Weight : 1.7 Kg Auto Interpretation Printing Modes: 4*3, Auto 3*4 +1, Auto 3*4, Auto 2*6 +1, Auto 2*6, Auto3-2+1, Auto3-2, Rhythm 4, Rhythm 3, Rhythm 2 And Manual mode. Optional : Touch Screen and Software for Interface
LED Characteristics Apparatus
2,080 - 3,200 Per piece
1 piece (MOQ)
Two round meters for voltage & current measurement, LED mounted on the panel, connections of Supplies & LED brought out at Sockets.
Precision Melting Point Apparatus
Get Price Quote
Cornsil Kjeldahl Digestion Unit
Get Price Quote
50 pcs (MOQ)
Kjeldahl Digestion Unit : This is very useful for estimation of nitrogen content in the substance by digestion for 300 or 500ml. Capacity flasks provided with LEAD FUME DUCT and pair of hangers. The unit works on 220/230V A.C. supply.
Laboratory CBR Apparatus Motorised
Get Price Quote
1 Piece (MOQ)
Mild Steel Slump Test Apparatus
Get Price Quote
100 Piece (MOQ)
Vega 204 TMT Stress Test System
Get Price Quote
1 Piece (MOQ)
Melting Point Apparatus
65,000 Per Piece
1 Piece (MOQ)
12 Lead ECG Machine
150,000 Per Piece
1 Piece(s) (MOQ)
Vaulting Horse
Get Price Quote
1 Piece(s) (MOQ)
GAGM-006 Vaulting Horse Features: • Vaulting Horse Covered with SYNTHETIC LEATHER. • Adjustable Height 110 to 150 cm. • Base pipe: 75mm Round x 3mm Thick
Brass frame sieves
450 - 600 Per PIECE
1 Piece (MOQ)
12 Channel Ecg Machine
Get Price Quote
1 piece (MOQ)
Diamond Mercurial Blood Pressure Apparatus
Get Price Quote
100 Piece (MOQ)
Reynolds Apparatus
Get Price Quote
We deal in high-quality Reynolds Apparatus, which is specially meant for deducing the Reynolds number and further the flow's type laminar or turbulent. We are reckoned among the leading Manufacturers and Suppliers of Reynolds Apparatus in Kolkata, West Bengal. The Apparatus is characterized by durability, user-friendly interface, hassle-free maintenance, space-spacing structure, rugged body, etc. And its quality is tested and ascertained on all the crucial parameters such as performance and life. Description : The apparatus consists of a glass tube with one end having bell mouth entrance; connected to a constant headwater tank, at the other end a valve is provided to vary the flow rate. The tank is of sufficient capacity to store water; A capillary tube is introduced centrally in the bell mouth for feeding dye from a small container placed at the top of tank, through polythene tubing. By varying the rate of flow, the Reynold's number is changed; this also changes the type of flow. Visual observation of dye (Thread) will indicate the type of flow, which can be confirmed from the Reynold's number computed. Present set-up is self contained water re-circulating unit, with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line. Flow rate of water is measured with the help of measuring cylinder and stop watch. Features : Choice of Test Section Closed loop water circulation Compact & stand alone set up MS Excel sample calculation program on demand Stainless Steel tanks and wetted parts Superb Painted structure Simple to operate & maintain Technical Details : Tube : Material Borosilicate Glass Dye vessel : Material Stainless Steel, Suitable Capacity Capillary Tube : Material Copper/Stainless Steel Constant Head Water Tank : Capacity 40 Ltrs MOC SS / MS with Powder Coated Flow Measurement : Using Measuring Cylinder./ Using Measuring Tank, Capacity 25 Ltrs. MOC SS / MS with Powder Coated Sump Tank : Capacity 60 Ltrs MOC SS / MS with Powder Coated Water Circulation : ½ HP Mono block Pump. Piping & Fittings : GI/PVC with necessary Valves. Stop Watch : Electronic Control Panel : ON/OFF Switch, Mains Indicator, etc. Utilities Required :Electric supply Provide: 230 +/-10 VAC, 50 Hz, Single phase Electric supply with proper earthing (Neutral, Earth voltage less than 5 VAC) 5A, three-pin socket with switch for pump Water supply Tap water connection BSP